DOWNLOAD Panasonic CS-E7GKDW / CU-E7GKD / CS-E9GKDW / CU-E9GKD / CS-E12GKDW / CU-E12GKD Service Manual ↓ Size: 13.11 MB | Pages: 71 in PDF or view online for FREE

Model
CS-E7GKDW CU-E7GKD CS-E9GKDW CU-E9GKD CS-E12GKDW CU-E12GKD
Pages
71
Size
13.11 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-e7gkdw-cu-e7gkd-cs-e9gkdw-cu-e9gkd-cs-e12gkdw-c.pdf
Date

Panasonic CS-E7GKDW / CU-E7GKD / CS-E9GKDW / CU-E9GKD / CS-E12GKDW / CU-E12GKD Service Manual ▷ View online

9
1. Cooling capacities are based on indoor temperature of 27
°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35
°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20
°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6
°C W.B. (42.8°F W.B.)
Note
• Specifications are subject to change without notice for further improvement.
Heat Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium (Blue Coat)
Fin Type
Slit Fin
Corrugated Fin
Row x Stage x FPI
2 x 15 x 21
2 x 24 x 17
Size (W x H x L)
mm
610 x 315 x 25.4
36.4 x 504 x 713
684
Air Filter
Material
Polypropelene
Type
One-Touch
Item
Unit
Power Source (Phase, Voltage, Cycle)
ø
Single
V
220 - 230
Hz
50
Input Power
W
Cooling; 950 (185 ~ 1200)
Heating; 1280 (175 ~ 1910)
Starting Current
A
6.1
Running Current
A
Cooling; 4.6 - 4.4
Heating; 6.1 - 5.9
Power Factor
%
Cooling; 94 - 94
Heating; 95 - 94
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
*Maximum over current protection
A
8.8
Power Cord
Number of core
Length
m
Thermostat
Electronic Control
Protection Device
Electronic Control
ITEM
UNIT
INDOOR UNIT
OUTDOOR UNIT
10
3 Features
• Product
- Four modes of operation selection
- Powerful mode to reach the desired room temperature
quickly with full power and a strong airflow
- Quiet mode to provide a quiet environment by reducing
the indoor unit operating airflow sound
- 24-hour ON Timer and OFF Timer setting
- Air swing manual and automatic adjusted by Remote
Control for vertical airflow and the horizontal airflow
direction louvers can be adjusted manually by hand
- Patrol sensor automatically detect the air quality. When
the air quality is unsatisfactory, e-ion operation will start
automatically.
- e-ion Air Purifying System provides clean air by
producing negative ions to attract dust which will then be
captured at the positively charged e-ion filters.
• Serviceability Improvement
- Removable and washable Front Panel
- Breakdown Self Diagnosis function
• Environmental Protection
- Non-ozone depletion substances refrigerant (R410A)
• Operation Improvement
- Random auto restart control after power failure for safety
restart operation
- Advanced inverter technology provides outstanding
energy efficiency and powerful, flexible, comfortable
operation
11
4 Location of Controls and Components
4.1.
Product Overview
4.1.1.
Indoor Unit
4.1.2.
Outdoor Unit
4.1.3.
Remote Control
12
5 Dimensions
5.1.
Indoor Unit
Page of 71
Display

Click on the first or last page to see other CS-E7GKDW / CU-E7GKD / CS-E9GKDW / CU-E9GKD / CS-E12GKDW / CU-E12GKD service manuals if exist.