Type
Propeller Fan
Material
PP
Motor Type
Induction (6-poles)
Input Power
W
—
Output Power
W
80
Speed
Hi
Cool
rpm
680 - 710
Heat
rpm
—
Moisture Removal
L/h (Pt/h)
4.5 (9.5)
Indoor Airflow
QLo
Cool
m
3
/min (ft
3
/min)
11.9 (420)
Heat
m
3
/min (ft
3
/min)
13.2 (466)
Lo
Cool
m
3
/min (ft
3
/min)
13.3 (470)
Heat
m
3
/min (ft
3
/min)
14.6 (516)
Me
Cool
m
3
/min (ft
3
/min)
16.3 (576)
Heat
m
3
/min (ft
3
/min)
17.3 (611)
Hi
Cool
m
3
/min (ft
3
/min)
19.3 (680)
Heat
m
3
/min (ft
3
/min)
20.1 (710)
Shi
Cool
m
3
/min (ft
3
/min)
20.1 (710)
Heat
m
3
/min (ft
3
/min)
20.6 (727)
Outdoor Airflow
Hi
Cool
m
3
/min (ft
3
/min)
52.4 (1850)
54.5 (1925)
Heat
m
3
/min (ft
3
/min)
52.4 (1850)
54.5 (1925)
Refrigeration Cycle
Control Device
Expansion Valve
Refrigerant Oil
cm
3
FV50S (800)
Refrigerant Type
g (oz)
R410A, 1.80k (63.5)
Dimension
Height (I/D / O/D)
mm (inch)
290 (11-7/16) / 795 (31-5/16)
Width (I/D / O/D)
mm (inch)
1070 (42-5/32) / 875 (34-15/32)
Depth (I/D / O/D)
mm (inch)
235 (9-9/32) / 320 (12-5/8)
Weight
Net (I/D / O/D)
kg (lb)
12 (26) / 66 (132)
P
I
P
I
N
G
G
Pipe Diameter (Liquid / Gas)
mm (inch)
6.35 (1/4) / 15.88 (5/8)
Standard Length
m (ft)
5.0 (16.4)
Length Range (min - max)
m (ft)
3 (9.8) ~ 30 (98.4)
I/D & O/D Height Different
m (ft)
20 (65.6)
Additional Gas Amount
g/m (oz/ft)
30 (0.3)
Length for Additional Gas
m (ft)
10 (32.8)
Drain Hose
Inner Diameter
mm
16
Length
mm
650
Indoor Heat
Exchanger
Exchanger
Fin Material
Aluminium (Pre Coat)
Fin Type
Slit Fin
Row
Stage FPI
2
15 21
Size (W
H L)
mm
810
315 25.4
Outdoor Heat
Exchanger
Exchanger
Fin Material
Aluminium (Blu Coat)
Fin Type
Corrugated Fin
Row
Stage FPI
2
30 19
Size (W
H L)
mm
38.1
762 895
865
Air Filter
Material
Polypropylene
Type
One-Touch
Power Supply
Outdoor Power Supply
Power Supply Cord
A
Nil
MODEL
INDOOR
CS-E28MKDS
OUTDOOR
CU-E28MKD
10
1. Cooling capacities are based on indoor temperature of 27
C Dry Bulb (80.6F Dry Bulb), 19.0C Wet Bulb (66.2F Wet Bulb)
and outdoor air temperature of 35
C Dry Bulb (95F Dry Bulb), 24C Wet Bulb (75.2F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20
C Dry Bulb (68F Dry Bulb) and outdoor air temperature of 7C Dry
Bulb (44.6
F Dry Bulb), 6C Wet Bulb (42.8F Wet Bulb)
3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20
C, outdoor 2/1C.
4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20
C, outdoor
-7/-8
C.
5. Specifications are subjected to change without prior notice for further improvement.
Thermostat
Electronic Control
Protection Device
Electronic Control
Dry Bulb
Wet Bulb
Indoor Operation Range
Cooling
Maximum
32
23
Minimum
16
11
Heating
Maximum
30
—
Minimum
16
—
Outdoor Operation Range
Cooling
Maximum
43
26
Minimum
16
11
Heating
Maximum
24
18
Minimum
-5
-6
MODEL
INDOOR
CS-E28MKDS
OUTDOOR
CU-E28MKD
11
3 Features
• Inverter Technology
- Wider output power range
- Energy saving
- Quick Cooling
- More precise temperature control
- Energy saving
- Quick Cooling
- More precise temperature control
• E-ion Air Purifying System with Patrol Sensor
- Active e-ions are released to catch dust particles and bring them back the large positively charged filter
• Environment Protection
- Non-ozone depletion substances refrigerant (R410A)
• Long Installation Piping
- CS/CU-E24/28MK, long piping up to 30 meter
• Easy to use remote control
• Quality Improvement
- Random auto restart after power failure for safety restart operation
- Gas leakage protection
- Prevent compressor reverse cycle
- Inner protector to protect compressor
- Noise prevention during soft dry operation
- Gas leakage protection
- Prevent compressor reverse cycle
- Inner protector to protect compressor
- Noise prevention during soft dry operation
• Operation Improvement
- Quiet mode to reduce the indoor unit operating sound
- Powerful mode to reach the desired room temperature quickly
- 24-hour timer setting
- Powerful mode to reach the desired room temperature quickly
- 24-hour timer setting
• Serviceability Improvement
- Breakdown Self Diagnosis function
12
4 Location of Controls and Components
4.1.
Indoor Unit
4.2.
Outdoor Unit
4.3.
Remote Control
Click on the first or last page to see other CS-E24MKDS / CU-E24MKD / CS-E28MKDS / CU-E28MKD service manuals if exist.