DOWNLOAD Panasonic CS-E24MKDS / CU-E24MKD / CS-E28MKDS / CU-E28MKD Service Manual ↓ Size: 16.72 MB | Pages: 113 in PDF or view online for FREE

Model
CS-E24MKDS CU-E24MKD CS-E28MKDS CU-E28MKD
Pages
113
Size
16.72 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-e24mkds-cu-e24mkd-cs-e28mkds-cu-e28mkd.pdf
Date

Panasonic CS-E24MKDS / CU-E24MKD / CS-E28MKDS / CU-E28MKD Service Manual ▷ View online

9
O
U
T
D
O
O
R
F
A
N
Type
Propeller Fan
Material
PP
Motor Type
Induction (6-poles)
Input Power
W
Output Power
W
80
Speed
Hi
Cool
rpm
680 - 710
Heat
rpm
Moisture Removal
L/h (Pt/h)
4.5 (9.5)
Indoor Airflow
QLo
Cool
m
3
/min (ft
3
/min)
11.9 (420)
Heat
m
3
/min (ft
3
/min)
13.2 (466)
Lo
Cool
m
3
/min (ft
3
/min)
13.3 (470)
Heat
m
3
/min (ft
3
/min)
14.6 (516)
Me
Cool
m
3
/min (ft
3
/min)
16.3 (576)
Heat
m
3
/min (ft
3
/min)
17.3 (611)
Hi
Cool
m
3
/min (ft
3
/min)
19.3 (680)
Heat
m
3
/min (ft
3
/min)
20.1 (710)
Shi
Cool
m
3
/min (ft
3
/min)
20.1 (710)
Heat
m
3
/min (ft
3
/min)
20.6 (727)
Outdoor Airflow
Hi
Cool
m
3
/min (ft
3
/min)
52.4 (1850)
54.5 (1925)
Heat
m
3
/min (ft
3
/min)
52.4 (1850)
54.5 (1925)
Refrigeration Cycle
Control Device
Expansion Valve
Refrigerant Oil
cm
3
FV50S (800)
Refrigerant Type
g (oz)
R410A, 1.80k (63.5)
Dimension
Height (I/D / O/D)
mm (inch)
290 (11-7/16) / 795 (31-5/16)
Width (I/D / O/D)
mm (inch)
1070 (42-5/32) / 875 (34-15/32)
Depth (I/D / O/D)
mm (inch)
235 (9-9/32) / 320 (12-5/8)
Weight
Net (I/D / O/D)
kg (lb)
12 (26) / 66 (132)
P
I
P
I
N
G
Pipe Diameter (Liquid / Gas)
mm (inch)
6.35 (1/4) / 15.88 (5/8)
Standard Length
m (ft)
5.0 (16.4)
Length Range (min - max)
m (ft)
3 (9.8) ~ 30 (98.4)
I/D & O/D Height Different
m (ft)
20 (65.6)
Additional Gas Amount
g/m (oz/ft)
30 (0.3)
Length for Additional Gas
m (ft)
10 (32.8)
Drain Hose
Inner Diameter
mm
16
Length
mm
650
Indoor Heat
Exchanger
Fin Material
Aluminium (Pre Coat)
Fin Type
Slit Fin
Row 
— Stage — FPI
— 15 — 21
Size (W 
— H — L)
mm
810 
— 315 — 25.4
Outdoor Heat
Exchanger
Fin Material
Aluminium (Blu Coat)
Fin Type
Corrugated Fin
Row 
— Stage — FPI
— 30 — 19
Size (W 
— H — L)
mm
38.1 
— 762 — 895
                     865
Air Filter
Material
Polypropylene
Type
One-Touch
Power Supply
Outdoor Power Supply
Power Supply Cord
A
Nil
 MODEL
INDOOR
CS-E28MKDS
OUTDOOR
CU-E28MKD
10
1. Cooling capacities are based on indoor temperature of 27
“C Dry Bulb (80.6“F Dry Bulb), 19.0“C Wet Bulb (66.2“F Wet Bulb)
and outdoor air temperature of 35
“C Dry Bulb (95“F Dry Bulb), 24“C Wet Bulb (75.2“F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20
“C Dry Bulb (68“F Dry Bulb) and outdoor air temperature of 7“C Dry
Bulb (44.6
“F Dry Bulb), 6“C Wet Bulb (42.8“F Wet Bulb)
3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20
“C, outdoor 2/1“C.
4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20
“C, outdoor
-7/-8
“C.
5. Specifications are subjected to change without prior notice for further improvement.
Thermostat
Electronic Control
Protection Device
Electronic Control
Dry Bulb
Wet Bulb
Indoor Operation Range
Cooling
Maximum
32
23
Minimum
16
11
Heating
Maximum
30
Minimum
16
Outdoor Operation Range
Cooling
Maximum
43
26
Minimum
16
11
Heating
Maximum
24
18
Minimum
-5
-6
 MODEL
INDOOR
CS-E28MKDS
OUTDOOR
CU-E28MKD
11
3 Features
• Inverter Technology
- Wider output power range
- Energy saving
- Quick Cooling
- More precise temperature control
• E-ion Air Purifying System with Patrol Sensor
- Active e-ions are released to catch dust particles and bring them back the large positively charged filter
• Environment Protection
- Non-ozone depletion substances refrigerant (R410A)
• Long Installation Piping
- CS/CU-E24/28MK, long piping up to 30 meter
• Easy to use remote control
• Quality Improvement
Random auto restart after power failure for safety restart operation
- Gas leakage protection
- Prevent compressor reverse cycle
- Inner protector to protect compressor
- Noise prevention during soft dry operation
• Operation Improvement
Quiet mode to reduce the indoor unit operating sound
- Powerful mode to reach the desired room temperature quickly
- 24-hour timer setting
• Serviceability Improvement
Breakdown Self Diagnosis function
12
4 Location of Controls and Components
4.1.
Indoor Unit
4.2.
Outdoor Unit
4.3.
Remote Control
Page of 113
Display