16.1.4.
To remove the Discharge Grille
• Pull out the Drain Hose (Behind the Discharge Grille) from
outlet to remove the Discharge Grille. (Fig. 8)
Fig. 8
16.1.5.
To remove the Control Board
• Release the 3 screws (Fig. 9)
• By pressing down the hook at the left, you will be able to
• By pressing down the hook at the left, you will be able to
remove the Control Board. (Fig. 9)
Fig. 9
16.1.6.
To remove the Cross Flow Fan and Indoor Fan Motor
• Remove the screw at the Cross Flow Fan. (Fig. 10)
Reminder:-
To reinstall the Fan Motor, please adjust the connector
location is positioned 90
To reinstall the Fan Motor, please adjust the connector
location is positioned 90
° with Fan Motor before fixing
Control Board. (Fig. 10)
• Remove the Bearing. (Fig. 11)
• Remove the screws at the left of the Evaporator. (Fig. 11)
• Remove the screws at the left of the Evaporator. (Fig. 11)
Fig. 10
Fig. 11
54
• Push up the Evaporator and pull out the Cross Flow Fan
from shaft.
By then, Fan Motor can be taken out. (Fig. 12)
By then, Fan Motor can be taken out. (Fig. 12)
Fig. 12
55
17 Technical Data
17.1. Operation Characteristics
17.1.1.
CS-E24GKES CU-E24GKE
Cooling Characteristic at Different Outdoor Air Temperature
Condition
Indoor room temperature: 27/19 °C
Remote control setting: HI fan, COOL 16 °C
Compressor frequency: Rated cooling
Voltage: 230 V
Indoor room temperature: 27/19 °C
Remote control setting: HI fan, COOL 16 °C
Compressor frequency: Rated cooling
Voltage: 230 V
56