DOWNLOAD Panasonic CS-E24GKES / CU-E24GKE / CS-E28GKE / CU-E28GKE Service Manual ↓ Size: 14.09 MB | Pages: 78 in PDF or view online for FREE

Model
CS-E24GKES CU-E24GKE CS-E28GKE CU-E28GKE
Pages
78
Size
14.09 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-e24gkes-cu-e24gke-cs-e28gke-cu-e28gke.pdf
Date

Panasonic CS-E24GKES / CU-E24GKE / CS-E28GKE / CU-E28GKE Service Manual ▷ View online

5
1. Cooling capacities are based on indoor temperature of 27
°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35
°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20
°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6
°C W.B. (42.8°F W.B.)
Note
• Specifications are subject to change without notice for further improvement.
Heat Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium
Fin Type
Slit Fin
Corrugated Fin
Row x Stage x FPI
2 x 15 x 21
2 x 30 x 19
Size (W x H x L)
mm
810 x 315 x 25.4
38.1 x 762 x 873.8
903.8
Air Filter
Material
Polypropelene
Type
One-Touch
Item
Unit
Power Source (Phase, Voltage, Cycle)
ø
Single
V
230
Hz
50
Input Power
W
Cooling; 2.12k (350 ~ 2.70k)
Heating; 2.66k (360 ~ 3.20k)
Starting Current
A
12.5
Running Current
A
Cooling; 9.7
Heating; 12.1
Power Factor
%
Cooling; 95
Heating; 96
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
*Maximum over current protection
A
14.6
Power Cord
Number of core
Length
m
Thermostat
Electronic Control
Protection Device
Electronic Control
ITEM
UNIT
INDOOR UNIT
OUTDOOR UNIT
6
2.2.
CS-E28GKE  CU-E28GKE
ITEM
UNIT
INDOOR UNIT
OUTDOOR UNIT
Performance Test Condition
EUROVENT
C
O
O
L  
N
G
Capacity
kW
7.65 (0.90 ~ 8.60)
BTU/h
26100 (3070 ~ 29300)
kCal/h
6580 (770 ~ 7400)
EER
W/W
3.01 (2.57 ~ 2.92)
BTU/hW
10.3 (8.8 ~ 9.9)
Noise Level
dB (A)
High 49, Low 38
High 53
Power level dB
62
67
H
E
A
T  
N
G
Capacity
kW
9.60 (0.90 ~ 11.00)
BTU/h
32700 (3070 ~ 37500)
kCal/h
8260 (770 ~ 9460)
COP
W/W
2.91 (2.50 ~ 2.90)
BTU/hW
9.9 (8.5 ~ 9.9)
Noise Level
dB (A)
High 48, Low 38
High 53
Power level dB
61
67
Moisture Removal
l/h
4.5
pt/h
9.5
Air Volume
Lo
m
3
/min (ft
3
/min)
Cooling; 12.8 (450)
Heating; 14.0 (490)
Me
m
3
/min (ft
3
/min)
Cooling; 15.2 (540)
Heating; 16.0 (570)
Hi
m
3
/min (ft
3
/min)
Cooling; 17.7 (625)
Cooling; 54.5 (1925)                
Heating; 18.7 (660)
Heating; 54.5 (1925)
Refrigeration Control Device
Expansion Valve
Refrigeration Oil
cm
3
FV50S (800)
Refrigerant (R410A)
g (oz)
1.69k (59.7)
Dimension
Height
mm (inch)
275 (10-13/16)
795 (31-5/16)
Width
mm (inch)
998 (39-9/32)
900 (35-7/16)
Depth
mm (inch)
230 (9-1/16)
320 (12-19/32)
Net Weight
kg (lbs)
11 (24)
70 (154)
Pipe Diameter
Gas
mm (inch)
15.88 (5/8)
Liquid
mm (inch)
6.35 (1/4)
Standard Length
m (ft)
5.0 (16.4)
Pipe Length Range
m (ft)
3 (9.8) ~ 30 (98.4)
Height Difference
m (ft)
20 (65.6)
Additional Gas Amount
g/m (oz/ft)
30 (0.3)
Refrigeration Charge Less
m (ft)
10 (32.8)
Drain Hose
Inner Diameter
mm
12
Length
mm
650
Compressor
Type
Hermetic Motor
Motor Type
Brushless (4-pole)
Rated Output
W
1.7k
Fan
Type
Cross-Flow Fan
Propeller Fan
Material
ASHT-18
PP
Motor Type
Transistor (8-pole)
Induction (6-pole)
Input Power
W
163
Output Power
W
30
76
Fan Speed
Lo (Cool/Heat)
rpm
 1190 / 1280
Me (Cool/Heat)
rpm
1410 / 1500
Hi (Cool/Heat)
rpm
1640 / 1720
700 / 700
7
1. Cooling capacities are based on indoor temperature of 27
°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35
°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20
°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6
°C W.B. (42.8°F W.B.)
Note
• Specifications are subject to change without notice for further improvement.
Heat Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium
Fin Type
Slit Fin
Corrugated Fin
Row x Stage x FPI
2 x 15 x 21
2 x 30 x 19
Size (W x H x L)
mm
810 x 315 x 25.4
38.1 x 762 x 873.8
903.8
Air Filter
Material
Polypropelene
Type
One-Touch
Item
Unit
Power Source (Phase, Voltage, Cycle)
ø
Single
V
230
Hz
50
Input Power
W
Cooling; 2.54k (350 ~ 2.95k)
Heating; 3.30k (360 ~ 3.79k)
Starting Current
A
15.3
Running Current
A
Cooling; 11.8
Heating; 15.3
Power Factor
%
Cooling; 94
Heating; 94
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
*Maximum over current protection
A
15.9
Power Cord
Number of core
Length
m
Thermostat
Electronic Control
Protection Device
Electronic Control
ITEM
UNIT
INDOOR UNIT
OUTDOOR UNIT
8
3 Features
• Product
- Four modes of operation selection
- Powerful mode to reach the desired room temperature
quickly with full power and a strong airflow
- Quiet mode to provide a quiet environment by reducing
the indoor unit operating airflow sound
- 24-hour ON Timer and OFF Timer setting
- Air swing manual and automatic adjusted by Remote
Control for vertical and horizontal airflow.
- Patrol sensor automatically detect the air quality. When
the air quality is unsatisfactory, e-ion operation will start
automatically.
- e-ion Air Purifying System provides clean air by
producing negative ions to attract dust which will then be
captured at the positively charged e-ion filters.
• Serviceability Improvement
- Removable and washable Front Panel
- Breakdown Self Diagnosis function
• Environmental Protection
- Non-ozone depletion substances refrigerant (R410A)
• Operation Improvement
- Random auto restart control after power failure for safety
restart operation
- Advanced inverter technology provides outstanding
energy efficiency and powerful, flexible, comfortable
operation
Page of 78
Display