Panasonic CS-E18JKEW / CU-E18JKE / CS-E21JKEW / CU-E21JKE / CS-XE18JKEW / CS-XE21JKEW Service Manual ▷ View online
65
16.5.2.
H12 (Indoor/Outdoor Capacity Rank Mismatched)
Malfunction Decision Conditions
• During startup, error code appears when different types of indoor and outdoor units are interconnected.
Malfunction Caused
• Wrong models interconnected.
• Wrong indoor unit or outdoor unit PCBs mounted.
• Indoor unit or outdoor unit PCBs defective.
• Indoor-outdoor unit signal transmission error due to wrong wiring.
• Indoor-outdoor unit signal transmission error due to breaking of wire 3 in the connection wires between the indoor and outdoor
• Wrong indoor unit or outdoor unit PCBs mounted.
• Indoor unit or outdoor unit PCBs defective.
• Indoor-outdoor unit signal transmission error due to wrong wiring.
• Indoor-outdoor unit signal transmission error due to breaking of wire 3 in the connection wires between the indoor and outdoor
units.
Troubleshooting
66
16.5.3.
H14 (Indoor Intake Air Temperature Sensor Abnormality)
Malfunction Decision Conditions
• During startup and operation of cooling and heating, the temperatures detected by the indoor intake air temperature sensor are
used to determine sensor errors.
Malfunction Caused
• Faulty connector connection.
• Faulty sensor.
• Faulty PCB.
• Faulty sensor.
• Faulty PCB.
Troubleshooting
67
16.5.4.
H15 (Compressor Temperature Sensor Abnormality)
Malfunction Decision Conditions
• During startup and operation of cooling and heating, the temperatures detected by the outdoor compressor temperature sensor
are used to determine sensor errors.
Malfunction Caused
• Faulty connector connection.
• Faulty sensor.
• Faulty PCB.
• Faulty sensor.
• Faulty PCB.
Troubleshooting
68
16.5.5.
H16 (Outdoor Current Transformer Open Circuit)
Malfunction Decision Conditions
• A current transformer (CT) is detected by checking the compressor running frequency ( rated frequency) and CT detected input
current (less than 0.65A) for continuously 20 seconds.
Malfunction Caused
• CT defective.
• Outdoor PCB defective.
• Compressor defective (low compression).
• Outdoor PCB defective.
• Compressor defective (low compression).
Troubleshooting
Click on the first or last page to see other CS-E18JKEW / CU-E18JKE / CS-E21JKEW / CU-E21JKE / CS-XE18JKEW / CS-XE21JKEW service manuals if exist.