DOWNLOAD Panasonic CS-E18JKEW / CU-E18JKE / CS-E21JKEW / CU-E21JKE / CS-XE18JKEW / CS-XE21JKEW Service Manual ↓ Size: 7.99 MB | Pages: 113 in PDF or view online for FREE

Model
CS-E18JKEW CU-E18JKE CS-E21JKEW CU-E21JKE CS-XE18JKEW CS-XE21JKEW
Pages
113
Size
7.99 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-e18jkew-cu-e18jke-cs-e21jkew-cu-e21jke-cs-xe18j.pdf
Date

Panasonic CS-E18JKEW / CU-E18JKE / CS-E21JKEW / CU-E21JKE / CS-XE18JKEW / CS-XE21JKEW Service Manual ▷ View online

13
CU-4E27CBPG
Three-room 
Operation
3.2 + 4.0 +
5.0
Cooling
8.00
2.9 - 8.4
2.35
0.49 - 2.82
10.30
Heating
9.40
4.1 - 10.5
2.10
0.70 - 3.10
9.20
3.2 + 5.0 +
5.0
Cooling
8.00
2.9 - 8.5
2.35
0.52 - 2.81
10.30
Heating
9.40
4.2 - 10.5
2.06
0.70 - 3.08
9.05
4.0 + 4.0 +
4.0
Cooling
7.98
2.9 - 8.4
2.39
0.49 - 2.84
10.50
Heating
9.39
4.0 - 10.5
2.10
0.68 - 3.08
9.20
4.0 + 5.0 +
5.0
Cooling
8.00
2.9 - 8.4
2.39
0.52 - 2.81
10.50
Heating
9.40
4.2 - 10.5
2.08
0.70 - 3.08
9.15
Four-room 
Operation
2.2 + 2.2 +
2.2 + 2.2
Cooling
8.00
2.7 - 8.8
2.15
0.49 - 2.84
9.50
Heating
9.40
3.2 - 10.5
2.08
0.55 - 3.14
9.15
2.2 + 2.2 +
2.2 + 2.8
Cooling
8.00
2.8 - 8.8
2.14
0.49 - 2.88
9.40
Heating
9.40
3.2 - 10.5
2.06
0.55 - 3.12
9.05
2.2 + 2.2 +
2.2 + 3.2
Cooling
8.00
2.8 - 8.9
2.13
0.49 - 2.88
9.40
Heating
9.40
3.4 - 10.5
2.12
0.59 - 3.18
9.30
2.2 + 2.2 +
2.2 + 4.0
Cooling
8.00
2.8 - 8.9
2.11
0.49 - 2.87
9.30
Heating
9.40
3.8 - 10.5
2.09
0.64 - 3.14
9.20
2.2 + 2.2 +
2.2 + 5.0
Cooling
8.00
2.8 - 8.9
2.11
0.49 - 2.84
9.30
Heating
9.40
4.0 - 10.5
2.12
0.68 - 3.11
9.30
2.2 + 2.2 +
2.8 + 2.8
Cooling
8.00
2.8 - 8.8
2.13
0.49 - 2.87
9.40
Heating
9.40
3.5 - 10.5
2.05
0.61 - 3.11
9.05
2.2 + 2.2 +
2.8 + 3.2
Cooling
8.00
2.8 - 8.9
2.12
0.49 - 2.87
9.30
Heating
9.40
3.7 - 10.5
2.10
0.62 - 3.16
9.20
2.2 + 2.2 +
2.8 + 4.0
Cooling
8.00
2.8 - 8.9
2.09
0.49 - 2.84
9.20
Heating
9.40
3.9 - 10.5
2.07
0.66 - 3.11
9.10
2.2 + 2.2 +
2.8 + 5.0
Cooling
8.00
2.9 - 8.9
2.11
0.52 - 2.88
9.30
Heating
9.40
4.1 - 10.5
2.09
0.70 - 3.10
9.20
2.2 + 2.2 +
3.2 + 3.2
Cooling
8.00
2.8 - 8.9
2.09
0.50 - 2.87
9.20
Heating
9.40
3.8 - 10.5
2.11
0.64 - 3.19
9.30
2.2 + 2.2 +
3.2 + 4.0
Cooling
8.00
2.8 - 8.9
2.08
0.50 - 2.84
9.15
Heating
9.40
4.0 - 10.5
2.08
0.68 - 3.15
9.15
2.2 + 2.2 +
3.2 + 5.0
Cooling
8.00
2.9 - 9.0
2.04
0.52 - 2.86
8.95
Heating
9.40
4.1 - 10.5
2.11
0.70 - 3.08
9.30
2.2 + 2.2 +
4.0 + 4.0
Cooling
8.00
2.9 - 9.0
2.06
0.52 - 2.85
9.05
Heating
9.40
4.1 - 10.5
2.05
0.70 - 3.11
9.05
2.2 + 2.2 +
4.0 + 5.0
Cooling
8.00
2.9 - 9.0
2.02
0.52 - 2.88
8.85
Heating
9.40
4.2 - 10.5
2.08
0.70 - 3.06
9.15
2.2 + 2.8 +
2.8 + 2.8
Cooling
8.00
2.8 - 8.8
2.12
0.49 - 2.85
9.30
Heating
9.40
3.8 - 10.5
2.04
0.64 - 3.08
8.95
2.2 + 2.8 +
2.8 + 3.2
Cooling
8.00
2.8 - 8.9
2.10
0.49 - 2.85
9.20
Heating
9.40
3.9 - 10.5
2.08
0.66 - 3.13
9.15
2.2 + 2.8 +
2.8 + 4.0
Cooling
8.00
2.8 - 8.9
2.13
0.49 - 2.86
9.40
Heating
9.40
4.0 - 10.5
2.05
0.68 - 3.08
9.05
2.2 + 2.8 +
2.8 + 5.0
Cooling
8.00
2.9 - 8.9
2.11
0.52 - 2.86
9.30
Heating
9.40
4.2 - 10.5
2.08
0.70 - 3.08
9.15
2.2 + 2.8 +
3.2 + 3.2
Cooling
8.00
2.8 - 8.9
2.13
0.50 - 2.85
9.40
Heating
9.40
4.0 - 10.5
2.09
0.68 - 3.18
9.20
2.2 + 2.8 +
3.2 + 4.0
Cooling
8.00
2.9 - 9.0
2.07
0.52 - 2.86
9.15
Heating
9.40
4.1 - 10.5
2.06
0.70 - 3.12
9.05
2.2 + 2.8 +
3.2 + 5.0
Cooling
8.00
2.9 - 9.0
2.03
0.52 - 2.84
8.95
Heating
9.40
4.2 - 10.5
2.09
0.70 - 3.08
9.20
2.2 + 2.8 +
4.0 + 4.0
Cooling
8.00
2.9 - 9.0
2.04
0.52 - 2.87
8.95
Heating
9.40
4.2 - 10.5
2.03
0.70 - 3.08
8.95
2.2 + 3.2 +
3.2 + 3.2
Cooling
8.00
2.8 - 9.1
2.04
0.50 - 2.87
8.95
Heating
9.40
4.0 - 10.6
2.11
0.68 - 3.12
9.30
2.2 + 3.2 +
3.2 + 4.0
Cooling
8.00
2.9 - 9.1
2.02
0.52 - 2.84
8.85
Heating
9.40
4.1 - 10.6
2.08
0.70 - 3.08
9.15
2.2 + 3.2 +
3.2 + 5.0
Cooling
8.00
3.0 - 9.2
2.00
0.53 - 2.87
8.80
Heating
9.40
4.2 - 10.6
2.11
0.70 - 3.06
9.30
Outdoor unit
Indoor unit combination
Operation 
mode
Capacity (kW)
Power Input (kW)
Current (A)
Operation
Class (kW)
Rating
min - max
Rating
min - max
14
CU-4E27CBPG
Four-room 
Operation
2.2 + 3.2 +
4.0 + 4.0
Cooling
8.00
2.9 - 9.1
2.09
0.52 - 2.86
9.20
Heating
9.40
4.2 - 10.6
2.06
0.70 - 3.06
9.05
2.8 + 2.8 +
2.8 + 2.8
Cooling
8.00
2.8 - 8.8
2.11
0.49 - 2.84
9.30
Heating
9.40
3.9 - 10.5
2.03
0.66 - 3.08
8.95
2.8 + 2.8 +
2.8 + 3.2
Cooling
8.00
2.8 - 8.9
2.09
0.49 - 2.87
9.20
Heating
9.40
4.0 - 10.5
2.06
0.68 - 3.10
9.05
2.8 + 2.8 +
2.8 + 4.0
Cooling
8.00
2.9 - 8.9
2.12
0.52 - 2.85
9.30
Heating
9.40
4.1 - 10.5
2.04
0.70 - 3.07
8.95
2.8 + 2.8 +
2.8 + 5.0
Cooling
8.00
2.9 - 8.9
2.11
0.52 - 2.85
9.30
Heating
9.40
4.2 - 10.5
2.07
0.70 - 3.07
9.15
2.8 + 2.8 +
3.2 + 3.2
Cooling
8.00
2.9 - 9.0
2.08
0.50 - 2.87
9.15
Heating
9.40
4.2 - 10.5
2.07
0.68 - 3.14
9.15
2.8 + 2.8 +
3.2 + 4.0
Cooling
8.00
2.9 - 9.0
2.05
0.52 - 2.88
9.05
Heating
9.40
4.2 - 10.5
2.04
0.70 - 3.08
8.95
2.8 + 2.8 +
4.0 + 4.0
Cooling
8.00
3.0 - 9.0
2.04
0.52 - 2.86
8.95
Heating
9.40
4.2 - 10.5
2.02
0.70 - 3.07
8.85
2.8 + 3.2 +
3.2 + 3.2
Cooling
8.00
2.9 - 9.1
2.03
0.52 - 2.86
8.95
Heating
9.40
4.1 - 10.6
2.09
0.70 - 3.10
9.20
2.8 + 3.2 +
3.2 + 4.0
Cooling
8.00
2.9 - 9.1
2.01
0.52 - 2.88
8.85
Heating
9.40
4.2 - 10.6
2.07
0.70 - 3.08
9.15
3.2 + 3.2 +
3.2 + 3.2
Cooling
8.00
2.9 - 9.2
2.00
0.53 - 2.85
8.80
Heating
9.40
4.2 - 10.6
2.11
0.70 - 3.08
9.30
3.2 + 3.2 +
3.2 + 4.0
Cooling
8.00
3.0 - 9.2
1.98
0.53 - 2.87
8.70
Heating
9.40
4.2 - 10.6
2.08
0.70 - 3.06
9.10
Outdoor unit
Indoor unit combination
Operation 
mode
Capacity (kW)
Power Input (kW)
Current (A)
Operation
Class (kW)
Rating
min - max
Rating
min - max
15
3 Features
• Inverter Technology
- Wider output power range
- Energy saving
- Quick Cooling
- More precise temperature control
• E-ion Air Purifying System with Patrol Sensor
- Active e-ions are released to catch dust particles and bring them back the large positively charged filter
• Environment Protection
- Non-ozone depletion substances refrigerant (R410A)
• Long Installation Piping
Long piping up to 20 meter during single split connection only
• Easy to use remote control
• Quality Improvement
Random auto restart after power failure for safety restart operation
- Gas leakage protection
- Prevent compressor reverse cycle
- Inner protector to protect compressor
- Noise prevention during soft dry operation
• Operation Improvement
Quiet mode to reduce the indoor unit operating sound
- Powerful mode to reach the desired room temperature quickly
- 24-hour timer setting
• Serviceability Improvement
Breakdown Self Diagnosis function
16
4 Location of Controls and Components
4.1.
Indoor Unit
4.2.
Outdoor Unit
4.3.
Remote Control
Page of 113
Display