Panasonic CS-E10HD3EA / CS-E15HD3EA / CS-E18HD3EA / CU-E10HBEA / CU-E15HBEA / CU-E18HBEA Service Manual ▷ View online
57
16 Disassembly and Assembly Instructions
16.1. Disassembly of Parts
16.1.1.
Detaching the Upper and Inner Casing
1. Unscrew the 10 screws on the Upper and Inner Casing
and detach them
16.1.2.
Detaching the Control Board
1. Unscrew the 2 screws on the Control Board and open the
Control Board Cover.
2. Pull the Control Board down following the Slide Guide.
3. Lift the Control Board up from the bottom, disengage the
Catch holding the Board.
WARNING
High Voltage are generated in the electrical parts area by the capacitor. Ensure that the capacitor has discharged sufficiently before proceeding
with repair work. Failure to heed tis caution may result in electric shocks.
with repair work. Failure to heed tis caution may result in electric shocks.
58
16.1.3.
Detaching the Fan
1. First detach the Upper and Inner Casing (16.1.1)
2. Disengage the 4 catches (2 each on the left and right) on
the Air Guide.
3. Use a 2.5 mm hexagonal wrench to loosen the 2 bolts
connecting the Fan Motor and Fan, detach the shaft
connecting the Fan Motor and Fan, loosen the screw
holding the Fan and detach the Fan.
connecting the Fan Motor and Fan, loosen the screw
holding the Fan and detach the Fan.
16.1.4.
Detaching the Fan Motor and Drain Motor
1. First detach the Upper and Inner Casing (16.1.1) and the
Fan (16.1.3).
2. Unscrew the 4 screws holding the Fan Motor and detach
it.
1. First detach the Upper and Inner Casing (16.1.1) and the
Fan (16.1.3).
2. From the Fan Motor side, undo the 2 hexagon bolts and
detach the Drain Motor.
Fan Motor
Drain Motor
59
16.1.5.
Outdoor Electronic Controller Removal Procedure
1. Remove the top panel and front panel
Fig. 8
2. Remove the Outdoor Electronic Controller
Fig. 9
Fig. 10
• Be save to return the wiring to its original position
• There are many high voltage components within the heat sink
• There are many high voltage components within the heat sink
cover so never touch the interior during operation. Wait at
least two minutes after power has been turned off.
least two minutes after power has been turned off.
Caution! When handling electronic controller, be careful of
electrostatic discharge.
electrostatic discharge.
60
17 Technical Data
17.1. Operation Characteristics
17.1.1.
CS-E10HD3EA CU-E10HBEA
Click on the first or last page to see other CS-E10HD3EA / CS-E15HD3EA / CS-E18HD3EA / CU-E10HBEA / CU-E15HBEA / CU-E18HBEA service manuals if exist.