Panasonic CS-C7JKD / CS-C9JKD / CS-C12JKD / CU-C7JKD / CU-C9JKD / CU-C12JKD Service Manual ▷ View online
8
Maximum 43
26
Outdoor Operation Range
Minimum 16
11
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2. Specifications are subjected to change without prior notice for further improvement.
9
Indoor CS-C12JKD
Model
Outdoor CU-C12JKD
Performance Test Condition
NEW JIS
Phase, Hz
SINGLE, 50
Power Supply
V 220 240
kW 3.52
3.54
BTU/h 12000
12100
Capacity
kcal/h 3030
3050
Running Current
A
5.3
5.2
Input Power
W
1.11k
1.15k
W/W 3.17
3.08
EER
Btu/hW 10.8
10.5
Power Factor
%
95
92
dB-A
39 / 29
39 / 29
Indoor Noise (H / L)
Power Level dB
52 / -
52 / -
dB-A
48 / -
49 / -
Cooling
Outdoor Noise (H / L)
Power Level dB
63 / -
64 / -
Max Current (A) / Max Input Power (W)
7.0 / 1.55k
Starting Current (A)
26.0
Type
Hermetic
Motor
Motor Type
Induction (2-poles)
Compressor
Output Power
W
950
Type Cross-Flow
Fan
Material
ASG20K1
Motor Type
Induction (4-poles)
Input Power
W
46.6 - 49.5
Output Power (I/D / O/D)
W
24
QLo
rpm
730 - 730
Lo
rpm
800 - 800
Me
rpm
940 - 940
Hi
rpm
1080 - 1080
Indoor Fan
Speed
SHi
rpm
1150 - 1150
Type Propeller
Fan
Material
PP
Resin
Motor Type
Induction (6-poles)
Input Power
W
66.6 - 74.6
Output Power
W
30
Outdoo
r Fa
n
Speed
Hi
rpm
815 - 850
Moisture Removal
L/h (Pt/h)
2.1 (4.4)
Lo m
3
/min (ft
3
/min)
8.0 (283) - 8.0 (283)
Me m
3
/min (ft
3
/min)
9.4 (332) - 9.4 (332)
Hi m
3
/min (ft
3
/min)
10.8 (381) - 10.8 (381)
Indoor Airflow
SHi m
3
/min (ft
3
/min)
11.5 (406) - 11.5 (406)
Outdoor Airflow
Hi
m
3
/min (ft
3
/min)
22.0 (780) - 23.6 (830)
Control Device
Capillary tube
Refrigerant Oil
cm
3
Atmos NM56M or Suniso 4GDID (350)
Refrigeration Cycle
Refrigerant Type
g (oz)
R22, 840 (29.7)
Height(I/D / O/D)
mm (inch)
290 (11-7/16)
510 (20-3/32)
Width (I/D / O/D)
mm (inch)
870 (34-9/32)
650 (25-19/32)
Dimension
Depth (I/D / O/D)
mm (inch)
204 (8-1/16)
230 (9-1/16)
Weight
Net (I/D / O/D)
kg (lb)
9 (20)
27 (60)
Pipe Diameter (Liquid / Gas)
mm (inch)
6.35 (1/4) / 12.70 (1/2)
Standard length
m (ft)
7.5 (24.6)
Length range (min – max)
m (ft)
3 ~ 15 (9.8 ~ 49.2)
I/D & O/D Height different
m (ft)
5 (16.4)
Additional Gas Amount
g/m (oz/ft)
10 (0.1)
Piping
Length for Additional Gas
m (ft)
7.5 (24.6)
Inner Diameter
mm
16
Drain Hose
Length mm
550
Fin Material
Pre Coat
Fin Type
Slit Fin
Row x Stage x FPI
2 x 15 x 17
Indoor Heat
Exchanger
Size (W x H x L)
mm
610 x 315 x 25.4
Fin Material
Blue Coated
Fin Type
Slit Fin
Row x Stage x FPI
2 x 23 x 17
Outdoor Heat
Exchanger
Size (W x H x L)
mm
25.4 x 483 x 553.4:573.4
Material
Polypropelene
Air Filter
Type
One-touch
Power Supply
Indoor
Power Supply Cord
A
10
Thermostat
-
Protection Device
2-stage Overload Protector
Dry Bulb
Wet Bulb
Maximum 32
23
Indoor Operation Range
Minimum 16
11
10
Maximum 43
26
Outdoor Operation Range
Minimum 16
11
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2. Specifications are subjected to change without prior notice for further improvement.
11
3. Features
x E-ion Air Purifying System with Patrol Sensor
o Active e-ions are released to catch dust particles and bring them back the large positively charged filter.
o Patrol Sensor color changes to indicate the dirt level in the air
x Long Installation Piping
o CS/CU-C7JK, CS/CU-C9JK, long piping up to 10 meters.
o CS/CU-C12JK, long piping up to 15 meters.
x Easy to use remote control
x Quality
Improvement
o Random auto restart after power failure for safety restart operation
o Gas
leakage
protection
o Prevent compressor reverse cycle
o Inner protector to protect compressor
o Noise prevention during soft dry operation
o Blue coated condenser for high resistance to corrosion
x Operation
Improvement
o Quiet mode to reduce the indoor unit operating sound
o Powerful mode to reach the desired room temperature quickly
o 24-hour timer setting
Click on the first or last page to see other CS-C7JKD / CS-C9JKD / CS-C12JKD / CU-C7JKD / CU-C9JKD / CU-C12JKD service manuals if exist.