36 
12.13 Patrol 
Operation 
 
x  To monitor air dirtiness level by using Patrol sensor and to maintain air freshness by activates e-ion operation  
 
x  Patrol operation starts condition 
o  When the unit operation is started with “OFF/ON” button 
o  When the unit stops, “Patrol” button is pressed, Patrol individual operation will start. 
o  During cooling only operation, “Patrol” button is pressed. 
 
x  Patrol operation stops condition (when any of the following condition is fulfilled): 
o  When “OFF/ON” button is pressed. 
o  During any operation with Patrol, “Patrol” button is pressed again. 
o  When “e-ion” button is pressed. 
o  When OFF Timer activates. 
 
x  Patrol operation disable 
o  To disable the Patrol Operation during unit starts (default) with “OFF/ON” button, press “Patrol” button and 
hold for 5 seconds, then release. 
To disable the Patrol Operation, press “Patrol” button and hold for 15 seconds, then release. 
e-ion activates when 
Patrol LED turns red. 
Press “OFF/ON” 
OFF timer activates 
Press “OFF/ON” 
Press “OFF/ON” 
OFF timer activates
ON Timer activates 
Press “Mode” 
Cooling Mode only 
Indicator LED 
Power e-ion  Patrol 
 
 
Cooling Mode with  
Patrol operation (Default) 
Indicator LED 
Power e-ion  Patrol 
 
Press “Patrol” 
Press “Patrol” 
Air quality 
improved 
Cooling Mode with e-ion 
Indicator LED 
Power e-ion  Patrol 
 
 
Operation stop 
Indicator LED 
Power e-ion  Patrol 
 
Patrol individual operation 
 
Indicator LED 
Power e-ion  Patrol 
 
Press “Patrol” 
 
Press “Patrol” 
OFF Timer 
activates 
Air quality 
improved 
e-ion operation 
Indicator LED 
Power e-ion  Patrol 
Press “OFF/ ON” 
Press 
“Patrol” 
LED off 
LED on 
Press “OFF/ ON” 
Press “Patrol” 
Patrol LED Air Quality 
 
Blue 
 Clean 
 
Orange 
 Moderate 
 
Red 
 Dirty 
Air dirty /
Air refreshment 
Air dirty / 
Air refreshment 
37 
x  Patrol Sensor Control 
o  First 2 minutes from Patrol function activates is stabilization time, during stabilization time, no air dirtiness 
level is monitored. The Air Dirtiness level is set to Clean, Patrol LED turns blue color. 
o  After that, Patrol sensor starts to record the resistance value at fixed interval. Higher resistance value 
indicates cleaner air. 
o  The air dirtiness level is monitored by comparing the current resistance value with maximum resistance value 
from time to time to get the Air Dirtiness Value. 
o  There are 3 air dirtiness level, based on the Air Dirtiness Value: 
ƒ  Air Dirtiness level 0: Clean    
– Patrol LED = blue color 
ƒ  Air Dirtiness level 1: Moderate  
– Patrol LED = orange color 
ƒ  Air Dirtiness level 2: Contaminated   – Patrol LED = red color 
 
Air Dirtiness Level 0 
 
 
Air Quality Worsen 
 
 
 
 
               G1 
 
 
Air Dirtiness Level 1 
G3 
 
 
 
 
 
 
 
 
 
 
G2 
 
 
      G4 
 
Air Dirtiness Level 2 
 
 
 
 
 
          Air Quality Improve 
 
x  Dirtiness level sensitivity adjustment 
It is possible to change the Patrol sensor sensitivity, where the Threshold value (G1 ~ G4) will be shifted 
accordingly:  
Press and release “SET” button. 
Press Timer  / Timer button to select sensitivity.  
(Air 1 “Low Sensitivity” Air 2 “Standard” (Default)  Air 3 “High Sensitivity”) 
Confirm setting by pressing “Timer Set” button. LCD returned to original display after 2 seconds. 
LCD returned to original display if remote control does not operate for 30 seconds 
 
x e-ion 
Control 
o  e-ion operation starts condition 
ƒ  When dirtiness at level 2 (Patrol LED turns red). 
o  e-ion operation time 
ƒ  If dirtiness level improves from level 2 to level 1 (Patrol LED from red to orange), the unit carries out level 
change after 60 seconds.  
ƒ  When dirtiness level returns to level 0 (Patrol LED turns blue) continuously for 11 minutes or more, e-ion 
operation stops. 
 
x  Dirtiness Level and fan speed 
o  When e-ion operation starts, the fan speed increases based on dirtiness level: 
 rpm 
shift 
 
Dirtiness level 
Patrol individual operation 
Combine operation 
Dirtiness level 0 
No change 
No change 
Dirtiness level 1 
+ 20 
+ 20 
e-ion ON 
Dirtiness level 2 
+ 40 
+ 40 
 
o  Indoor Fan Control 
ƒ  During any operation mode combines with Patrol operation, fan speed follows respective operation mode. 
ƒ  During Patrol individual operation if e-ion starts, only Auto Fan Speed and no Powerful operation is 
allowed. Even if “Fan Speed” button is pressed, no signal is sent to air conditioner, and no change on 
LCD display. 
ƒ  During Patrol individual operation if e-ion stops, Indoor Fan stop operation. 
 
x  Airflow direction (Horizontal, Vertical) Control 
o  During any operation mode combines with Patrol operation, air flow direction follows respective operation 
mode. 
o  During Patrol individual operation if e-ion starts, only Auto Air Swing is allowed. Even if “Air Swing” button is 
pressed, no signal is sent to air conditioner, and no change on LCD display. 
o  During Patrol individual operation if e-ion stops, Airflow direction louver closed. 
 
Air Dirtine
ss Value 
Dirty 
    Moderate 
       
   Clean 
38 
x Indicator 
o  When Patrol operation starts, Patrol LED is ON with 3 different colors: 
 
 
 
 
o  Then e-ion operation starts based on dirtiness level, both Patrol LED and e-ion LED are ON 
 
x  Remote Control Receiving Sound 
o  
Normal 
Operation 
ΠPatrol Mode   
: Beep 
o  
Patrol 
Mode   
ΠStop  
 
: Long Beep 
o  
Patrol 
Mode   
ΠNormal Operation  : Beep 
o  
Stop   
 
ΠPatrol 
 
: Beep 
 
x Timer 
Control 
o  When ON timer activates when unit stops, previous operation resumes and restored last saved Patrol 
operation status. 
o  When ON timer activates during any operation, no change and carry on current operation. 
o  When OFF timer activates during any operation, all operation stops and the latest Patrol operation status is 
saved. 
 
x  Power Failure Control 
o  During Patrol individual operation, if power failure occurs, after power resumes, Patrol individual operation 
resumes immediately. 
o  During combination operation, if power failure occurs, after power resumes combination operation resume 
immediately. 
o  When e-ion operation is ON during Patrol operation, if power failure occurs, after power resumes, only Patrol 
operation will resume but e-ion operation will not resume. 
 
x  Error Detection Control 
o  The Patrol error detection control starts once the power is supplied to Patrol sensor. However, the error will 
display when the Patrol operation is ON. 
o  Error detection method: 
ƒ  If the Patrol sensor is opened circuit continuously for 6 hours, Patrol sensor error occurs. However, the 
error will display only when the Patrol operation is ON. 
o  Patrol Sensor Control after error occurs 
ƒ  During any operation mode combines with Patrol operation 
x  Power supply to Patrol sensor is OFF 
x  Air conditioner normal mode operation continues with Patrol LED blinking. 
x  The Patrol LED continues blinking if the patrol operation is ON and stops blinking if the patrol 
operation is OFF. 
ƒ  During Patrol individual mode 
x  Power supply to Patrol sensor is OFF 
x  Patrol LED blinks. 
x  The Patrol LED continues blinking if the Patrol operation is ON and stops blinking if the Patrol 
operation is OFF 
o  Error cancel condition: 
o  Power supply reset 
 
x  Patrol Operation Demo Mode 
o  Patrol Operation Demo Mode start condition 
ƒ  Press “Auto OFF/ON” button at indoor unit for 5 seconds to enter Forced Cooling Operation, then press 
“Patrol” button at remote control for 5 seconds and release.  
o  The Patrol indicator change color every 10 seconds follows the pattern below for demo purpose: 
 
BLUE
(10 seconds)
(10 seconds)
ORANGE
(10 seconds)
(10 seconds)
RED
(10 seconds)
 
 
o  During demo, all operation stops, remote control buttons and auto OFF/ON button are ignored. 
o  Patrol Operation Demo Mode stop condition 
ƒ  Press “Patrol” button for 5 seconds and release. 
ƒ  Power supply reset. 
Patrol LED 
Air Quality 
Blue Clean 
Orange Moderate 
Red Dirty 
39 
Cooling Mode only 
Indicator LED 
Power e-ion  Patrol 
 
Cooling Mode with  
e-ion operation 
Indicator LED 
Power e-ion  Patrol 
 
Press e-ion 
Press e-ion 
Operation stop 
Indicator LED 
Power e-ion  Patrol 
 
 
 
e-ion individual operation 
 
Indicator LED 
Power e-ion  Patrol 
 
Press e-ion 
Press e-ion 
OFF Timer 
activates 
Press “OFF/ON” 
OFF timer activates 
Press “OFF/ON” 
OFF timer activates
ON Timer activates 
Press “Mode” 
LED off 
LED on 
12.14  
e-ion  operation 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
x  This operation provides clean air by producing negative ions to attract dust captured at the positively charged 
active e-ion filters. 
 
x  e-ion operation start condition 
o  During unit running at any operation mode, if “e-ion” button is pressed, combination operation (operation 
mode + e-ion operation) starts. 
o  During unit is OFF, if “e-ion” button is pressed, e-ion individual operation starts. 
 
x  e-ion operation stop condition 
o  When “OFF/ON” button is pressed to stop the operation. 
o  When “e-ion” button is pressed again. 
o  When “Patrol” button is pressed. 
o  When OFF Timer activates. 
 
x  e-ion operation pause condition 
o  When indoor fan stop (during deice, odor cut control, thermostat off, etc.). e-ion operation resume after 
indoor fan restarts. 
o  When indoor intake temperature 40°C. e-ion operation resume after indoor intake temperature < 40°C 
continuously for 30 minutes. 
 
x Indoor 
fan 
control 
o  During any operation mode combines with e-ion operation, fan speed follows respective operation mode. 
o  During e-ion individual operation – only Auto Fan Speed and no Powerful operation is allowed. Even if Fan 
Speed button is pressed, no signal is sent to air conditioner, and no change on LCD display. 
 
x  Airflow direction control 
o  During any operation mode combines with e-ion operation, air flow direction follows respective operation 
mode. 
o  During e-ion individual operation, only Auto Air Swing is allowed. Even if Air Swing button is pressed, no 
signal is sent to air conditioner, and no change on LCD display. 
 
x Timer 
control 
o  When ON timer activates when unit stops, previous operation resumes and restored last saved e-ion 
operation status. 
o  When ON timer activates during any operation, no change and carry on current operation. 
o  When OFF timer activates during any operation, all operation stops and the latest e-ion operation status is 
saved. 
 
x Indicator 
o  When e-ion operation starts, e-ion indicator ON. 
 
 
 
Page of 63
Display