Panasonic CS-C7JKD / CS-C9JKD / CS-C12JKD / CU-C7JKD / CU-C9JKD / CU-C12JKD Service Manual ▷ View online
11
3. Features
x E-ion Air Purifying System with Patrol Sensor
o Active e-ions are released to catch dust particles and bring them back the large positively charged filter.
o Patrol Sensor color changes to indicate the dirt level in the air
x Long Installation Piping
o CS/CU-C7JK, CS/CU-C9JK, long piping up to 10 meters.
o CS/CU-C12JK, long piping up to 15 meters.
x Easy to use remote control
x Quality
Improvement
o Random auto restart after power failure for safety restart operation
o Gas
leakage
protection
o Prevent compressor reverse cycle
o Inner protector to protect compressor
o Noise prevention during soft dry operation
o Blue coated condenser for high resistance to corrosion
x Operation
Improvement
o Quiet mode to reduce the indoor unit operating sound
o Powerful mode to reach the desired room temperature quickly
o 24-hour timer setting
12
4. Location of Controls and Components
4.1 Indoor
Unit
4.2 Outdoor
Unit
4.3 Remote
Control
Remote control
e-ion operation
Operation mode
Off/On
Transmitter
Patrol operation
Temperature setting
Fan speed selection
Airflow direction
adjustment
adjustment
Timer setting
Powerful/Quite
operation
operation
display
Clock setting
• For normal operation, the button is not in use.
• Press button to restore the remote control’s default setting.
• Press button to restore the remote control’s default setting.
13
5. Dimensions
5.1 Indoor
Unit
<Top View>
870
60
125
(41-61)
410
115
60
47
0
2
1
Air intake
direction
direction
Left
piping
hole
piping
hole
Air outlet
direction
direction
<Side View>
Unit : mm
Remote control
<Side View>
<Front View>
<Back View>
Relative position between the indoor unit and the installation plate <Front View>
22
Right
piping
hole
piping
hole
29
0
16
4
204
Liquid side
Gas side
165
70.2
115.2
158
548
2.8
13.5
Indoor unit
external
dimensions
line
external
dimensions
line
Installation
plate
plate
Left
piping
hole
Right
piping
hole
14
5.2 Outdoor
Unit
Space necessary for
installation
Anchor Bolt Pitch
261 x 474
<Top View>
<Front View>
18
(650)
88
474
88
79
134
261
293
736
(18)
70
131
51
0
12
15
230
<Side View>
<Side View>
3-way valve at Gas side
(Low Pressure)
(Low Pressure)
2-way valve at Liquid side
(High Pressure)
(High Pressure)
10 cm
Unit: mm
10 cm
100 cm
Click on the first or last page to see other CS-C7JKD / CS-C9JKD / CS-C12JKD / CU-C7JKD / CU-C9JKD / CU-C12JKD service manuals if exist.