DOWNLOAD Panasonic CS-C7JKD / CS-C9JKD / CS-C12JKD / CU-C7JKD / CU-C9JKD / CU-C12JKD Service Manual ↓ Size: 3.9 MB | Pages: 63 in PDF or view online for FREE

Model
CS-C7JKD CS-C9JKD CS-C12JKD CU-C7JKD CU-C9JKD CU-C12JKD
Pages
63
Size
3.9 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-c7jkd-cs-c9jkd-cs-c12jkd-cu-c7jkd-cu-c9jkd-cu-c.pdf
Date

Panasonic CS-C7JKD / CS-C9JKD / CS-C12JKD / CU-C7JKD / CU-C9JKD / CU-C12JKD Service Manual ▷ View online

13.6
Compressor Reverse Rotation Protection 
Control ...................................................................43
13.7
Dew Prevention Control .............................44
14. Servicing Mode .................................................45
14.1
Auto OFF/ON Button ..................................45
14.2
Remote Control Button ...............................46
15. Troubleshooting Guide....................................47
15.1
Refrigeration cycle system .........................47
16. Disassembly and Assembly Instructions ......49
16.1
Indoor Electronic Controllers, Cross Flow 
Fan and Indoor Fan Motor Removal Procedures..49
17. Technical Data ..................................................53
17.1
Thermostat Characteristics ........................53
17.2
Operation Characteristics ...........................54
18. Exploded View and Replacement Pars List...60
18.1
Indoor Unit ..................................................60
18.2
Outdoor Unit ...............................................62
 
CAUTION 
WARNING 
WARNING 
1. Safety Precautions 
x  Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing. 
x  Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the 
power plug and main circuit for the model installed. 
x  The caution items stated here must be followed because these important contents are related to safety. The 
meaning of each indication used is as below. Incorrect installation or servicing due to ignoring of the instruction 
will cause harm or damage, and the seriousness is classified by the following indications. 
 
 
This indication shows the possibility of causing death or serious injury. 
 
This indication shows the possibility of causing injury or damage to properties. 
 
x  The items to be followed are classified by the symbols: 
 
 
x  Carry out test running to confirm that no abnormality occurs after the servicing. Then, explain to user the 
operation, care and maintenance as stated in instructions. Please remind the customer to keep the operating 
instructions for future reference. 
 
 
1.   Do not modify the machine, part, material during repairing service. 
2.   If wiring unit is supplied as repairing part, do not repair or connect the wire even only partial wire break. Exchange the whole wiring unit. 
3.   Do not wrench the fasten terminal. Pull it out or insert it straightly. 
4.   Engage dealer or specialist for installation and servicing. If installation of servicing done by the user is defective, it will cause water leakage, 
      electrical shock or fire. 
5.   Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electric shock or fire. 
6.   Use the attached accessories parts and specified parts for installation and servicing. Otherwise, it will cause the set to fall, water leakage, fire 
      or electrical shock. 
7.   Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly done,
      the set will drop and cause injury. 
8.   For electrical work, follow the local national wiring standard, regulation and the installation instruction. An independent circuit and single outlet
      must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire. 
9.   This equipment is strongly recommended to install with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD). Otherwise, it 
      may cause electrical shock and fire in case equipment breakdown or insulation breakdown. 
10. Use the specified indoor/outdoor connection cable [1.5 mm
2
 (1.0 ~ 1.5HP) or 2.5 mm
2
 (2.0 ~ 2.5HP)], and connect tightly for indoor/outdoor  
      connection. Connect tightly and clamp the cable so that no external force will be acted on the terminal. If connection or fixing is not perfect, it 
      will cause heat-up or fire at the connection. 
11. Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will cause 
      heat-up or fire at the connection point of terminal, fire or electrical shock. 
12. When carrying out piping connection, take care not to let air substances other than the specified refrigerant go into refrigeration cycle.  
      Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosive and injury. 
13. Do not install outdoor unit near handrail of veranda. When installing air-conditioner unit at veranda of high rise building, child may  
      climb up to outdoor unit and cross over the handrail and causing accident. 
14. This equipment must be properly earthed. Earth line must not be connected to gas pipe, water pipe, earth of lightning rod and  
      telephone. Otherwise, it may cause electric shock in case equipment breakdown or insulation breakdown. 
15. Keep away from small children, the thin film may cling to nose and mouth and prevent breathing. 
16. Do not damage or use unspecified power supply cord. Otherwise it will cause fire or electric shock.  
17. Do not modify the length of the power supply cord or use extension cord, and do not share the single outlet with other electric 
      appliances. Otherwise, it will cause fire or electric shock. 
18. During pump down operation, stop the compressor before remove the refrigeration piping. When remove piping while valve at open  
      condition, burst may occur and cause injury. 
19. During installation, before run the compressor, confirm the refrigerant pipes are fixed. Operation of compressor without fixing the piping, 
      setting the valves at open condition, a burst may occur and cause injury. 
 
This symbol denotes item that is PROHIBITED from doing. 
CAUTION 
WARNING 
 
 
20. After completion of installation or service, confirm there is no leakage or refrigerant gas. It may generate toxic gas when the refrigerant  
      contacts with fire. 
21. Ventilate if there is refrigerant gas leakage during operation. It may cause toxic gas when refrigerant contacts with fire. 
22. Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury. 
23. Must not use other parts except original parts described in catalog and manual. 
 
 
1.   Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of the  
      unit, it may cause fire. 
2.   Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage  
      the furniture. 
3.   Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare  
      may break and cause refrigerant gas leakage. 
4.   Do not touch outdoor unit air inlet and aluminium fin. It may cause injury. 
5.   Select an installation location which is easy for maintenance. 
6.   Pb free solder has a higher melting point than standard solder; typically the melting point is 50°F – 70°F (30°C – 40°C) higher. Please use 
      a high temperature solder iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C). 
      Pb free solder will tend to splash when heated too high (about 1100°F / 600°C). 
7.   Power supply connection to the air conditioner. Connect the power supply cord of the air conditioner to the mains using one of the following 
      methods. 
      Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency. In some countries, 
      permanent connection of this room air conditioner to the power supply is prohibited. 
      i. Power supply connection to the receptacle using a power plug. 
         Use an approved 15/16A (1.0~1.5HP) or 16A (2.0HP) or 20A (2.5HP) power 
         plug with earth pin for the connection to the socket. 
      ii. Power supply connection to a circuit breaker for the permanent component. 
          Use an approved 15/16A (1.0~1.5HP) or 20A (2.5HP) circuit  
          breaker for the permanent connection. It must be a double pole switch with a minimum 3.0 mm contact gap. 
8.   Do not release refrigerant during piping work for installation, servicing, reinstallation and during repairing a refrigerant parts. 
      Take care of the liquid refrigerant, it may cause frostbite 
9.   Installation or servicing work: It may need two people to carry out the installation or servicing work. 
10. Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc. 
11. Do not sit or step on the unit, you may fall down accidentally. 
12. Do not touch the sharp aluminium fin, sharp parts may cause injury. 
 
 
 
2. Specification 
 
Indoor CS-C7JKD 
Model 
Outdoor CU-C7JKD 
Performance Test Condition 
NEW JIS 
Phase, Hz 
SINGLE, 50 
Power Supply 
V 220  240 
kW 2.00 
2.02 
BTU/h 6820 
6890 
Capacity 
kcal/h 1720 
1740 
Running Current 
3.0 
2.9 
Input Power 
590 
640 
W/W 3.39 
3.15 
EER 
Btu/hW 11.6 
10.8 
Power Factor 
96 
92 
dB-A 
33 / 26 
33 / 26 
Indoor Noise (H / L) 
Power Level dB 
46 / - 
46 / - 
dB-A 
46 / - 
47 / - 
Cooling 
Outdoor Noise (H / L) 
Power Level dB 
61 / - 
62 / - 
Max Current (A) / Max Input Power (W) 
3.4 / 760 
Starting Current (A) 
12.4 
Type  
Hermetic 
Motor 
Motor Type 
 
Induction (2-poles) 
Compressor 
Output Power 
550 
Type  Cross-Flow 
Fan 
Material  
ASG20K1 
Motor Type 
 
Induction (4-poles) 
Input Power 
36.7 - 38.1 
Output Power (I/D / O/D) 
19  
QLo 
rpm 
690 - 690 
Lo 
rpm 
740 - 740 
Me 
rpm 
840 - 840 
Hi 
rpm 
960 - 960 
Indoor Fan 
Speed 
SHi 
rpm 
1050 - 1050 
Type   Propeller 
Fan 
Material  
PP 
Resin 
Motor Type 
 
Induction (6-poles) 
Input Power 
66.0 - 75.0 
Output Power 
30 
Outdoo
r Fa
Speed 
Hi 
rpm 
800 - 830 
Moisture Removal 
L/h (Pt/h) 
1.3 (2.7) 
Lo m
3
/min (ft
3
/min) 
6.1 (215) - 6.1 (215) 
Me m
3
/min (ft
3
/min) 
6.9 (244) - 6.9 (244) 
Hi m
3
/min (ft
3
/min) 
7.9 (279) - 7.9 (279) 
Indoor Airflow 
SHi m
3
/min (ft
3
/min) 
8.6 (305) - 8.6 (305) 
Outdoor Airflow 
Hi 
m
3
/min (ft
3
/min) 
28.8 (1020) - 29.2 (1040) 
Control Device 
 
Capillary tube 
Refrigerant Oil 
cm
3
 
Atmos NM56M or Suniso 4GDID (290) 
Refrigeration Cycle 
Refrigerant Type 
g (oz) 
R22, 450 (15.9) 
Height(I/D / O/D) 
mm (inch) 
290 (11-7/16) 
510 (20-3/32) 
Width (I/D / O/D) 
mm (inch) 
870 (34-9/32) 
650 (25-19/32) 
Dimension 
Depth (I/D / O/D) 
mm (inch) 
204 (8-1/16) 
230 (9-1/16) 
Weight 
Net (I/D / O/D) 
kg (lb) 
9 (20) 
22 (49) 
Pipe Diameter (Liquid / Gas) 
mm (inch) 
6.35 (1/4) / 9.52 (3/8) 
Standard length 
m (ft) 
7.5 (24.6) 
Length range (min – max) 
m (ft) 
3 ~ 10 (9.8 ~ 32.8) 
I/D & O/D Height different 
m (ft) 
5 (16.4) 
Additional Gas Amount 
g/m (oz/ft) 
10 (0.1) 
Piping 
Length for Additional Gas 
m (ft) 
7.5 (24.6) 
Inner Diameter 
mm  
16 
Drain Hose 
Length mm 
550 
Fin Material 
 
Pre Coat 
Fin Type 
 
Slit Fin 
Row x Stage x FPI 
 
2 x 10 x 17 
Indoor Heat 
Exchanger 
Size (W x H x L) 
mm 
610 x 315 x 25.4 
Fin Material 
 
Blue Coated 
Fin Type 
 
Slit Fin 
Row x Stage x FPI 
 
1 x 23 x 17 
Outdoor Heat  
Exchanger 
Size (W x H x L) 
mm 
12.7 x 483 x 578.4 
Material  
Polypropelene 
Air Filter 
Type  
One-touch 
Power Supply 
 
Indoor 
Power Supply Cord 
10 
Page of 63
Display

Panasonic CS-C7JKD / CS-C9JKD / CS-C12JKD / CU-C7JKD / CU-C9JKD / CU-C12JKD Service Manual ▷ Download

  • DOWNLOAD Panasonic CS-C7JKD / CS-C9JKD / CS-C12JKD / CU-C7JKD / CU-C9JKD / CU-C12JKD Service Manual ↓ Size: 3.9 MB | Pages: 63 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Panasonic CS-C7JKD / CS-C9JKD / CS-C12JKD / CU-C7JKD / CU-C9JKD / CU-C12JKD in PDF for free, which will help you to disassemble, recover, fix and repair Panasonic CS-C7JKD / CS-C9JKD / CS-C12JKD / CU-C7JKD / CU-C9JKD / CU-C12JKD Air Conditioner. Information contained in Panasonic CS-C7JKD / CS-C9JKD / CS-C12JKD / CU-C7JKD / CU-C9JKD / CU-C12JKD Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.