21 
11.2  Indoor Unit  
11.2.1  How to Fix Installation Plate 
The mounting wall shall be strong and solid enough to prevent it from vibration. 
 
 
 
Model 
Dimension 
1
 
2
 
3
 
4
 
5
 
6
 
BE20***, 
KE25***, BE25***, DE25***, 
KE35***, BE35***, DE35*** 
480 mm 
90 mm 
425 mm 
425 mm 
43 mm 
95 mm 
 
 
 
Model 
Dimension 
1
 
2
 
3
 
4
 
5
 
6
 
KE50***, BE50***, DE50*** 
490 mm 
85 mm 
439 mm 
432 mm 
43 mm 
95 mm 
 
The center of installation plate should be at more than 1 at right and left of the wall. 
The distance from installation plate edge to ceiling should more than 2. 
From installation plate center to unit’s left side is 3. 
From installation plate center to unit’s right side is 4. 
B
 
: For left side piping, piping connection for liquid should be about 5 from this line. 
 
: For left side piping, piping connection for gas should be about 6 from this line. 
1  Mount the installation plate on the wall with 5 screws or more (at least 5 screws). 
(If mounting the unit on the concrete wall, consider using anchor bolts.) 
o
 
Always mount the installation plate horizontally by aligning the marking-off line with the thread and using 
a level gauge. 
2  Drill the piping plate hole with ø70 mm hole-core drill. 
o
 
Line according to the left and right side of the installation plate. 
The meeting point of the extended line is the center of the hole. 
Another method is by putting measuring tape at position as shown in the diagram above. 
The hole center is obtained by measuring the distance namely 128 mm for left and right hole 
respectively. 
o
 
Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor 
side. 
3
4
B
A
C
Ceiling
Wall
Wall
Installation 
plate 
1
2 screw
More than 
1
More than 
1
Measuring Tape
Indoor unit
228 mm
128 mm
228 mm
128 mm
More than 
2
For best strength of 
INDOOR unit installation, 
it is highly recommended 
to locate “ ” at 5 position 
as shown. 
PIPE 
HOLE 
CENTER
PIPE 
HOLE 
CENTER
128mm TO 
PIPE HOLE 
CENTER
128mm TO 
PIPE HOLE 
CENTER
3
4
B
A
C
Ceiling
Wall
Wall
Installation 
plate 
1
2 screw
More than 
1
More than 
1
Measuring Tape
Indoor unit
241.5 mm
128 mm
241.5 mm
128 mm
More than 
2
For best strength of 
INDOOR unit installation, 
it is highly recommended 
to locate “ ” at 5 position 
as shown. 
PIPE 
HOLE 
CENTER
PIPE 
HOLE 
CENTER
128mm TO 
PIPE HOLE 
CENTER
128mm TO 
PIPE HOLE 
CENTER
22 
11.2.2  To Drill a Hole in the Wall and 
Install a Sleeve of Piping 
1  Insert the piping sleeve to the hole. 
2  Fix the bushing to the sleeve. 
3  Cut the sleeve until it extrudes about 15 mm 
from the wall. 
 
 
 CAUTION
 
   
           
 
 When the wall is hollow, please be sure to use the
  sleeve for tube assembly to prevent dangers 
  caused by mice biting the connection cable. 
 
4  Finish by sealing the sleeve with putty or 
caulking compound at the final stage. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Putty or caulking compound
Sleeve for 
tube assembly
Approx. 5 - 7 mm
Bushing for tube assembly
Wall
ø70 mm 
through hole
Indoor
Outdoor
15 mm
23 
11.2.3  Indoor Unit Installation 
 
11.2.3.1  For the Right Rear Piping 
 
11.2.3.2  For the Right and Right  
Bottom Piping 
 
11.2.3.3  For the Embedded Piping 
 
 
 
 
 
 
 
 
 
 
 
(This can be used for left rear piping and bottom 
piping also.) 
 
 Do not turn over the unit without it’s shock absorber during pull out the piping.
It may cause intake grille damage.
 
 Use shock absorber during pull out the piping to protect the intake grille from damage.
Intake grille
Piping
pull ou
t the
 pip
in
g
Piping
Shock absorber
pull o
ut t
he
 p
ip
in
g
Install the Indoor Unit
Pull out the Indoor piping
Step-2
Secure the Indoor Unit
Insert the power supply cord and connection cable
Step-1
Step-3
Step-4
• Insert the cables from bottom of the unit through the control board hole until
 
terminal board area.
Install the Indoor Unit
Pull out the Indoor piping
Step-2
Insert the power supply cord and connection cable
Secure the Indoor Unit
Step-1
Step-3
Step-4
• Insert the cables from bottom of the unit through the control board hole until
  terminal board area.
• Use a spring bender or equivalent to bend the piping so that the piping is not 
    crushed.
• When determining the dimensions of the piping, slide the unit all the way to the  
    left on the installation plate.
• Refer to the section “Cutting and flaring the piping”.
Bend the embedded piping
Cut and flare the embedded piping
Replace the drain hose
Pull the connection cable into Indoor Unit
• The power supply cord and indoor unit and outdoor unit connection cable can
  be connected without removing the front grille.
• Please refer to “Connecting the piping” column in outdoor unit section. 
    (Below  steps  are  done after connecting the outdoor piping and gas-leakage 
    confirmation.)
Connect the piping
• Please refer to “Insulation of piping connection” column as mentioned in
  indoor/outdoor unit installation.
Install the Indoor Unit
Secure the Indoor Unit
Insulate and finish the piping
Step-1
Step-2
Step-3
Step-4
Step-5
Step-6
Step-7
Step-8
In case of the cover is cut, keep the cover at the rear 
of chassis as shown in the illustration for future 
reinstallation. 
(Left, right and 2 bottom covers for piping.)
How to keep the cover
Hook the indoor unit onto the upper  
portion of installation plate. (Engage the  
indoor unit with the upper edge of the 
installation plate). Ensure the  hooks are  
properly seated on the installation plate
by moving it in left and right. 
Press the lower left and right side of the unit against 
the installation plate until hooks engages with their 
slot (sound click).
Right Rear piping
Right and Right Bottom piping
Install the indoor unit
Secure the Indoor Unit
Insert the connection cable
Cover for the 
bottom piping
Cover for the 
bottom piping
Tape it with piping in a 
position as mentioned 
in Fig. below.
Cover for 
the right 
piping
Piping
Drain 
hose
Cover for 
the left 
piping
Cover for 
the bottom 
piping
Tape it with piping in a 
position as mentioned 
in Fig. below.
Cover for 
the right 
piping
Piping
Drain hose
Cover for 
the left 
piping
Drain hose
Sleeve for piping hole
Indoor unit
Hooks at installation 
plate
Piping
Cover for piping
Guide 
surface
Connection cable
About 
70 – 80 mm
Connection cable
Gas side piping
Liquid side piping
Drain hose
Installation 
plate
Unit’s hook
To take out the unit, push the          marking at the bottom
unit, and pull it slightly towards you to disengage the hooks
from the unit.
g
n
i
k
r
a
m
 
24 
 
11.2.4  Connect the Cable to the Indoor Unit 
The power supply cord, indoor and outdoor unit connection cable can be connected without removing the front grille. 
1  Install the indoor unit on the installing holder that mounted on the wall. 
2  Open the front panel and grille door by loosening the screw. 
3  Cable connection to the power supply through Isolating Devices (Disconnecting means). 
o
 
Connect approved type polychloroprene sheathed power supply cord 3 x 1.5 mm
2
 (3/4 ~ 1.5HP) or 3 x 
2.5 mm
2
 (2.0HP) type designation 60245 IEC 57 or heavier cord to the terminal board, and connect the 
others end of the cord to Isolating Devices (Disconnecting means). 
o
 
Do not use joint power supply cord. Replace the wire if the existing wire (from concealed wiring, or 
otherwise) is too short. 
o
 
In unavoidable case, joining of power supply cord between isolating devices and terminal board of air 
conditioner shall be done by using approved socket and plug with earth pin rated 15/16A (3/4 ~ 1.5HP) 
or 16A (2.0HP). Wiring work to both socket and plug must follow to national wiring standard. 
4  Bind all the power supply cord lead wire with tape and route the power supply cord via the left escapement. 
5  Connection cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed  
4 x 1.5 mm
2
 (3/4 ~ 1.5HP) or 4 x 2.5 mm
2
 (2.0HP) flexible cord, type designation 60245 IEC 57 or heavier 
cord. Do not use joint connection cable. Replace the wire if the existing wire (from concealed wiring, or 
otherwise) is too short. Allowable connection cable length of each indoor unit shall be 30 mm or less. 
6  Bind all the indoor and outdoor connection cable with tape and route the connection cable via the right 
escapement. 
 
 
 
 
 
 
 
 
 
How to pull the piping and drain hose out, in case of the 
embedded piping.
 
In case of left piping how to insert the 
connection cable and drain hose.
Rear view for left piping installation
Drain cap
Drain hose
Adjust the piping slightly 
downwards.
Drain hose
Connection cable
 
PVC tube 
for drain 
hose
Indoor unit
100 mm
Piping
Cable
Apply putty or 
caulking material 
to seal the wall 
opening.
Connection cable
Piping
More than 
470 mm
More than 
950 mm
PVC tube (VP-65) for piping 
and connection cable
PVC tube for drain hose (VP-30)
PVC tube for drain 
hose (VP-20)
More than 700 mm
Drain hose 
from main unit
Exchange the drain hose and cap
Cable
45°
Drain 
hose
Piping
Sleeve for piping hole
Drain hose
Piping
Connection cable
More than 950 mm
(For the right piping, follow the same procedure)