11.3.3. Indoor Unit Installation
22
23
11.3.4. Connect The Cable To The Indoor Unit
1. The inside and outside connecting cable can be connected without removing the front grille.
2.
• Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor’s respectively.
• Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires for safety reason.
11.3.5. Wire Stripping And Connecting Requirement
24
11.4. Outdoor Unit
11.4.1. Install The Outdoor Unit
• After selecting the best location, start installation according to Indoor/Outdoor Unit Installation Diagram.
1. Fix the unit on concrete or rigid frame firmly and
horizontally by bolt nut (ø10 mm).
2. When installing at roof, please consider strong wind and earthquake. Please fasten the installation stand firmly with bolt or
nails.
11.4.2. Connecting The Piping
Connecting The Piping To Indoor Unit
Please make flare after inserting flare nut (locate at joint portion
of tube assembly) onto the copper pipe. (In case of using long
piping)
Connect the piping
• Align the center of piping and sufficiently tighten the flare nut
with fingers.
• Further tighten the flare nut with torque wrench in specified
torque as stated in the table.
Connecting The Piping To Outdoor Unit
Decide piping length and then cut by using pipe cutter. Remove
burrs from cut edge.
Make flare after inserting the flare nut (locate at valve) onto the
copper pipe.
Align center of piping to valves and then tighten with torque
wrench to the specified torque as stated in the table.
Model
A
B
C
D
A7JKD, A9JKD
474 mm
87 mm
18.5 mm
261 mm
A12JKD
570 mm
105 mm
18.5 mm
320 mm
A18JKD, PA18JKD, 
A24JKD, PA24JKD, 
A28JKD
612.5 mm 131 mm
19 mm
383 mm
Piping size
Torque
1/4” [6.35 mm]
[18 N•m (1.8 kgf.m)]
3/8” (9.52 mm)
[42 N•m (4.3 kgf.m)]
1/2” (12.7 mm)
[55 N•m (5.6 kgf.m)]
5/8” (15.88 mm)
[65 N•m (6.6 kgf.m)]
3/4” (19.05 mm)
[100 N•m (10.2 kgf.m)]
Do not over tighten, over tightening cause gas leakage.
Page of 74