DOWNLOAD Panasonic CS-A18JKD / CU-A18JKD / CS-A24JKD / CU-A24JKD Service Manual ↓ Size: 6.01 MB | Pages: 68 in PDF or view online for FREE

Model
CS-A18JKD CU-A18JKD CS-A24JKD CU-A24JKD
Pages
68
Size
6.01 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-a18jkd-cu-a18jkd-cs-a24jkd-cu-a24jkd.pdf
Date

Panasonic CS-A18JKD / CU-A18JKD / CS-A24JKD / CU-A24JKD Service Manual ▷ View online

5
2 Specifications
Model
Indoor
CS-A18JKD
CS-A24JKD
Outdoor
CU-A18JKD
CU-A24JKD
Performance Test Condition
NEW JIS
NEW JIS
Power Supply
Phase, Hz
Single, 50
Single, 50
V
220
230
220
230
Cooling
Capacity
kW
5.30
5.30
7.03
7.03
BTU/h
18100
18100
24000
24000
Running Current
A
8.0
7.8
12.3
12.2
Input Power
W
1.72k
1.76k
2.54k
2.58k
EER
W/W
3.08
3.01
2.77
2.72
BTU/hW
10.52
10.28
9.45
9.30
Power Factor
%
98
98
94
92
Indoor Noise
dB-A (H/L)
43-43 / 38-38
47-47 / Low: 41-41
Power Level dB
59 / 59
63 / 63
Outdoor Noise
dB-A (H/L)
53 / 54
53 / 54
Power Level dB
68 / 69
68 / 69
Heating
Capacity
kW
5.65
5.70
7.80
7.80
BTU/h
19300
19400
26600
26600
Running Current
A
7.7
7.6
12.2
Input Power
W
1.65k
1.71k
2.53k
2.56k
COP
W/W
3.42
3.33
3.08
3.05
BTU/hW
11.70
11.35
10.51
10.39
Power Factor
%
97
98
94
91
Indoor Noise
dB-A (H/L)
42-42 / 38-38
46-46 / 41-41
Power Level dB
58 / 58
62 / 62
Outdoor Noise
dB-A (H/L)
54 / 55
54 / 55
Power Level dB
70 / 71
70 / 71
Max Current (A) / Max Input Power (W)
10.2 / 2.20k
15.8 / 3.30k
Starting Current (A)
40
65
Compressor
Type
Rotary (1 cylinder) rolling piston type
Rotary (1 cylinder) rolling piston type
Motor Type
Induction (2-poles)
Induction (2-poles)
Output Power
W
1.5k
2.0k
Indoo
r Fan
Type
Cross-flow Fan
Cross-flow Fan
Material
ASG30K1
ASG30K1
Motor Type
DC Motor
DC Motor
Input Power
W
94.8 - 94.8
94.8 - 94.8
Output Power
W
40
40
Speed
Lo
rpm
Cooling: 1040 - 1040
Heating: 1100 - 1100
Cooling: 1150 - 1150
Heating: 1230 - 1230
Me
rpm
Cooling: 1140 - 1140
Heating: 1140 - 1140
Cooling: 1270 - 1270
Heating: 1270 - 1270
Hi
rpm
Cooling: 1240 - 1240
Heating: 1270 - 1270
Cooling: 1390 - 1390
Heating: 1480 - 1480
SHi
rpm
Cooling: 1270 - 1270
Ou
tdoor F
a
n
Type
Propeller Fan
Propeller Fan
Material
PP
PP Resin
Motor Type
Induction (6-poles)
Induction (6-poles)
Input Power
W
150.3
150.3
Output Power
W
80
80
Speed
Lo
rpm
460 - 490
460 - 490
Hi
rpm
815 - 830
815 - 830
Moisture Removal
L/h (Pt/h)
2.9 (6.1)
4.0 (8.5)
6
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) 
and outdoor air temperature of 35
qC Dry Bulb (95qF Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry 
Bulb (44.6°FDry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Specifications are subjected to change without prior notice for further improvement.
Indoor Airflow
Lo
m
3
/min (ft
3
/m)
Cooling: 13.8 (486) - 13.8 (486)
Heating: 14.8 (523) - 14.8 (523)
Cooling: 15.4 (543) - 15.4 (543)
Heating: 16.6 (587) - 16.6 (587)
Me
m
3
/min (ft
3
/m)
Cooling: 15.1 (532) - 15.1 (532)
Heating: 15.3 (542) - 15.3 (542)
Cooling: 17.0 (600) - 17.0 (600)
Heating: 17.2 (606) - 17.2 (606)
Hi
m
3
/min (ft
3
/m)
Cooling: 16.4 (579) - 16.4 (579)
Heating: 17.1 (604) - 17.1 (604)
Cooling: 18.6 (657) - 18.6 (657)
Heating: 20.0 (706) - 20.0 (706)
SHi
m
3
/min (ft
3
/m)
16.8 (593) - 16.8 (593)
19.8 (699) - 19.8 (699)
Outdoor Airflow
Lo
m
3
/min (ft
3
/m)
28.6 (1010) - 30.5 (1080)
28.1 (990) - 29.9 (1060)
Hi
m
3
/min (ft
3
/m)
50.7 (1790) - 51.7 (1830)
49.7 (1750) - 50.7 (179)
Refrigeration Cycle
Control Device
Capillary Tube
Capillary Tube
Refrigerant Oil
cm
3
SUNISO 4GDID or ATMOS 
NM56M (700)
SUNISO 4GDID or ATMOS 
NM56M (1130)
Refrigerant Type
g (oz)
R22, 1710 (60.4)
R22, 2050 (72.4)
Dimension
Height (I/D / O/D)
mm (inch)
290 (11-7/16) / 750 (29-17/32)
290 (11-7/16) / 750 (29-17/32)
Width (I/D / O/D)
mm (inch)
1070 (42-5/32) / 875 (34-15/32)
1070 (42-5/32) / 875 (34-15/32)
Depth (I/D / O/D)
mm (inch)
235 (9-9/32) / 345 (13-19/32)
235 (9-9/32) / 345 (13-19/32)
Weight
Net (I/D / O/D)
kg (lb)
12 (26) / 60 (132)
12 (26) / 60 (132)
Piping
Pipe Diameter (Liquid / Gas)
mm (inch)
6.35 (1/4”) / 12.7 (1/2”)
6.35 (1/4”) / 15.8 (5/8”)
Standard length
m (ft)
5 (16.4)
7.5 (24.6)
Length range (min~max)
m (ft)
3~25 (9.8~82.0)
3~25 (9.8~82.0)
I/D & O/D Height different
m (ft)
20.0 (65.6)
20.0 (65.6)
Additional Gas Amount
g/m (oz/ft)
20 (0.2)
30 (0.3)
Length for Additional Gas
m (ft)
7.5 (24.6)
7.5 (24.6)
Drain Hose
Inner Diameter
mm
12
12
Length
mm
560
560
Indoor Heat Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium (Pre Coat)
Fin Type
Slit Fin
Slit Fin
Row 
u Stage u FPI
u 15 u 21
u 15 u 21
Size (W 
u H u L)
mm
810 
u 315 u 25.4
810 
u 315 u 25.4
Outdoor Heat Exchanger
Fin Material
Aluminium (Blue Coat)
Aluminium (Blue Coat)
Fin Type
Corrugated Fin
Corrugated Fin
Row 
u Stage u FPI
u 28 u 17
u 23 u 17
Size (W 
u H u L)
mm
44 
u 711.2 u 782.4
816.9
44 
u 711.2 u 782.4
816.9
Air Filter
Material
Polypropelene
Polypropelene
Type
One-touch
One-touch
Power Supply
Indoor Power Supply
Indoor Power Supply
Power Supply Cord
A
16
20
Thermostat
Protection Device
Inner Protector
Dry Bulb
Wet Bulb
Dry Bulb
Wet Bulb
Indoor Operation Range
Cooling
Maximum
32
23
32
23
Minimum
16
11
16
11
Heating
Maximum
30
30
Minimum
16
16
Outdoor Operation Range
Cooling
Maximum
43
26
43
26
Minimum
16
11
16
11
Heating
Maximum
24
18
24
18
Minimum
-5
-6
-5
-6
7
3 Features
• E-ion Air Purifying System with Patrol Sensor
- Active e-ions are released to catch dust particles and bring them back the large positively charged filter.
- Patrol Sensor color changes to indicate the dirt level in the air.
• Long Installation Piping
- CS/CU-A18/24JK, long piping up to 25 meters.
• Easy to use remote control
• Quality Improvement
- Random auto restart after power failure for safety restart operation.
- Gas leakage protection.
- Prevent compressor reverse cycle.
- Inner protector to protect compressor.
- Noise prevention during soft dry operation.
- Blue coated condenser for high resistance to corrosion.
• Operation Improvement
- Quiet mode to reduce the indoor unit operating sound.
- Powerful mode to reach the desired room temperature quickly.
- 24-hour timer setting.
8
4 Location of Controls and Components
4.1.
Indoor Unit
4.2.
Outdoor Unit
4.3.
Remote Control
Page of 68