2
12.14. Remote Control Signal Receiving Sound ---------- 44
12.15. Patrol Operation ------------------------------------------ 44
12.16. e-ion Operation ------------------------------------------- 46
13 Servicing Mode -------------------------------------------------- 49
13.1. Auto OFF/ON Button ------------------------------------ 49
13.2. Select Remote Control Transmission Code ------- 49
13.3. Remote Control Button --------------------------------- 50
14 Troubleshooting Guide---------------------------------------- 51
14.1. Refrigeration Cycle System --------------------------- 51
15 Disassembly and Assembly Instructions--------------- 53
15.1. Indoor Electronic Controllers and Control
Board Removal Procedures -------------------------- 53
15.2. Indoor Fan Motor and Cross Flow Fan
Removal Procedures ----------------------------------- 56
16 Technical Data --------------------------------------------------- 58
16.1. Thermostat Characteristics---------------------------- 58
16.2. Operation Characteristics ----------------------------- 59
17 Exploded View and Replacement Parts List----------- 67
17.1. Indoor Unit------------------------------------------------- 67
17.2. Outdoor Unit ---------------------------------------------- 69
1 Safety Precaution
• Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing.
• Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the power plug and
main circuit for the model installed.
• The caution items stated here must be followed because these important contents are related to safety. The meaning of each
indication used is as below. Incorrect installation or servicing due to ignoring of the instruction will cause harm or damage, and
the seriousness is classified by the following indications.
• The items to be followed are classified by the symbols:
• Carry out test running to confirm that no abnormality occurs after the servicing. Then, explain to user the operation, care and
maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference.
This indication shows the possibility of causing death or serious injury.
This indication shows the possibility of causing injury or damage to properties.
This symbol denotes item that is PROHIBITTED from doing.
1. Engage dealer or specialist for installation and servicing. If installation or servicing done by the user is defective, it will cause water 
leakage, electrical shock or fire.
2. Install according to this installation instruction strictly. If installation is defective, it will cause water leakage, electrical shock or fire.
3. Use the attached accessories parts and specified parts for installation and servicing. Otherwise, it will cause the set to fall, water leakage, 
fire or electrical shock.
4. Install at a strong and firm location which is able to withstand the set's weight. If the strength is not enough or installation is not properly 
done, the set will drop and cause injury.
5. For electrical work, follow the local national wiring standard, regulation and the installation instruction. An independent circuit and single 
outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire.
6. Use the specified cable and connect tightly for indoor/outdoor connection. Connect tightly and clamp the cable so that no external force will 
be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection.
7. Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will cause 
heat-up at connection point of terminal, fire or electrical shock.
8. When connecting the piping, do not allow air or any substances other than the specified refrigerant to enter the refrigeration 
cycle. Otherwise, this may lower the capacity, cause abnormally high pressure in the refrigeration cycle, and possibly result in 
explosion and injury.
3
9. It is desirable that the amount of residual oil is less than 40 mg/10 m.
10. Do not modify the length of the power supply cord or use of the extension cord, and do not share the single outlet with other 
electrical appliances. Otherwise, it will cause fire or electrical shock.
1. The equipment must be earthed. It may cause electrical shock if grounding is not perfect.
2. Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of 
the unit, it may cause fire.
3. Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the 
furniture.
4. Pb free solder has a higher melting point than standard solder; typically the melting point is 50 - 70°F (30 - 40°C) higher. Please use a high 
temperature soldering iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C).Pb free solder 
will tend to splash when heated too high (about 1100°F/600°C).
1. Selection of the installation location. Select an installation location which is rigid and strong enough to support or hold the unit, and select 
a location for easy maintenance.
2. Power supply connection to the conditioner. Connect the power supply cord of the air conditioner to the mains using one of the following 
methods.
Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency. 
In some countries, permanent connection of this room air conditioner to the power supply is prohibited.
1. Power supply connection to the receptacle using a power plug. Use an approved power plug with earth pin for the connection to the 
socket.
2. Power supply connection to a circuit breaker for the permanent connection. Use an approved circuit breaker for the permanent 
connection. It must be a double pole switch with a minimum 3.5 mm contact gap.
3. Do not release refrigerant during piping work for installation, servicing, reinstallation and during repairing a refrigeration parts. Take care of 
the liquid refrigerant, it may cause frostbite.
4. Installation work. It may need two people to carry out the installation work.
5. Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.
4
2 Specifications
2.1.
CS-A18GKD  CU-A18GKD
ITEM
UNIT
INDOOR UNIT
OUTDOOR UNIT
Performance Test Condition
NEW JIS
C
O
O
L
I
N
G
Capacity
kW
5.3 - 5.3
BTU/h
18,100 - 18,100
EER
W/W
3.08 - 3.01
BTU/hW
10.52 - 10.28
Noise Level
dB (A)
High 43 - 43, Low 38 - 38
High 53 - 54
H
E
A
T
I
N
G
Capacity
kW
5.65 - 5.70
BTU/h
19,300 - 19,400
COP
W/W
3.42 - 3.33
BTU/hW
11.70 - 11.35
Noise Level
dB (A)
High 42 - 42, Low 38 - 38
High 54 - 55
Moisture Removal
I/h
2.9
pt/h
6.1
Lo
m
3
/min (ft
3
/min)
Cooling; 13.0 (460) - 13.0 (460)
Heating; 14.2 (500) - 14.2 (500)
28.6 (1,010) - 30.5 (1,080)
Air Volume
Me
m
3
/min (ft
3
/min)
Cooling; 14.4 (510) - 14.4 (510)
Heating; 14.8 (520) - 14.8 (520)
Hi
m
3
/min (ft
3
/min)
Cooling; 15.3 (540) - 15.3 (540)
Heating; 16.0 (560) - 16.0 (560)
50.7 (1,790) - 51.7 (1,830)
SHi
m
3
/min (ft
3
/min)
Cooling 15.6 (550) - 15.6 (550)
Refrigeration Control Device
Capillary Tube
Refrigeration Oil
cm
3
SUNISO 4GDID or ATMOS
M60 or ATMOS 56M (1,000)
Refrigerant (R22)
g (oz)
1,710 (60.4)
Dimension
Height
mm (inch)
275 (10-13/16)
750 (29-17/32)
Width
mm (inch)
998 (39-9/32)
875 (34-7/16)
Depth
mm (inch)
230 (9-1/16)
345 (13-19/32)
Net Weight
kg (lbs)
11.0 (24)
60.0 (132)
Pipe Diameter
Gas
mm (inch)
12.7 (1/2)
Liquid
mm (inch)
6.35 (1/4)
Standard Length
m (ft)
5 (16.4)
Pipe Length Range
m (ft)
3 (9.8) ~ 25 (82.0)
Height Difference
m (ft)
20.0 (65.6)
Additional Gas Amount
g/m (oz/ft)
20 (0.2)
Refrigeration Charges Less
m (ft)
7.5 (24.6)
Drain Hose
Inner Diameter
mm
16
Length
mm
650
Compressor
Type
Rotary (1 cylinder)
rolling piston type
Motor Type
Induction (2-pole)
Rated Output
kW
1.5
Fan
Type
Cross-Flow Fan
Propeller Fan
Material
ASHT-18
PP
Motor Type
Transistor (8-poles)
Induction (6-poles)
Input Power
W
116 - 127
Output Power
W
30
80
Fan
Speed
Lo
rpm
Cooling; 1,190 - 1,190
Heating; 1,270 - 1,270
460 - 490
Me
rpm
Cooling; 1,320 - 1,320
Heating; 1,320 - 1,320
Hi
rpm
Cooling; 1,400 - 1,400
Heating; 1,430 - 1,430
815 - 830
Shi
rpm
Cooling; 1,430 - 1,430
Heat Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium (Blue Coated)
Fin Type
Slit Fin
Corrugated Fin
Row x Stage X FPI
2 x 15 x 21
2 x 28 x 16
Size (W x H x L)
mm
810 x 315 x 25.4
44 x 711.2 x 791
               826
Air Filter
Material
Polypropelene
Type
One-Touch
5
1. Cooling capacities are based on indoor temperature of 27
°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35
°C D.B. (95°F D.B.), 24°C D.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20
°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6
°C W.B. (42.8°F W.B.)
Note
• Specifications are subject to change without notice for further improvement.
ITEM
UNIT
Power Source (Phase, Voltage, Cycle)
ø
Single
V
220 - 230
Hz
50
Input Power
kW
Cooling: 1.72 - 1.76
Heating: 1.65 - 1.71
Starting Current
A
44.5
Running Current
A
Cooling: 8.0 - 7.8
Heating: 7.7 - 7.6
Power Factor
%
Cooling: 98 - 98
Heating: 97 - 98
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
*Maximum over current protection
A
10.2
Number of Core
3 (1.5mm
2
)
Power Cord
Length
m
1.9
Thermostat
Protection Device
Inner Protector
Page of 70
Display

Panasonic CS-A18GKD / CU-A18GKD / CS-A24GKD / CU-A24GKD Service Manual ▷ Download

  • DOWNLOAD Panasonic CS-A18GKD / CU-A18GKD / CS-A24GKD / CU-A24GKD Service Manual ↓ Size: 9.99 MB | Pages: 70 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Panasonic CS-A18GKD / CU-A18GKD / CS-A24GKD / CU-A24GKD in PDF for free, which will help you to disassemble, recover, fix and repair Panasonic CS-A18GKD / CU-A18GKD / CS-A24GKD / CU-A24GKD Air Conditioner. Information contained in Panasonic CS-A18GKD / CU-A18GKD / CS-A24GKD / CU-A24GKD Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.