DOWNLOAD LG WT1701CV / WT1701CW Service Manual ↓ Size: 20.91 MB | Pages: 56 in PDF or view online for FREE

Model
WT1701CV WT1701CW
Pages
56
Size
20.91 MB
Type
PDF
Document
Service Manual
Brand
Device
Washing Machine
File
wt1701cv-wt1701cw.pdf
Date

LG WT1701CV / WT1701CW Service Manual ▷ View online

25
9) Disassembly of Rotor and Stator
      
① 
    
Use a wrench (M24) to remove the nut that 
connects the rotor to the shaft. 
(The torque should be 200 kgf/cm or 88 foot-
pounds.)
      
② 
    
Remove the rotor by pulling it straight off the  
splined shaft. 
7)  Disassembly of the Back Cover and 
Drain Pump 
      
① 
    
Remove the screws that attach the back cover and 
take it off. 
      
② 
    
Disconnect the leads and the drain hose from the 
drain pump.
      
③ 
    
Remove the pump attachment screws and the lead 
connector. Take the pump assembly out of the 
washer. 
8) Disassembly of Damper Assembly 
     
① 
  Remove the top cover  and the back cover of the 
washing machine.
     
②   
Pull out the hinge which connect the horizontal 
damper with outer tub.( To disassembly the 
horizontal damper, take the horizontal damper out 
of the holder.)
     
③ 
  As shown in the drawing, lift the damper assembly 
and remove it along with the outer tub assembly.
     
④   
Damper assembly shall not be disassembled. 
Replace damper as assembly.
     
④   
Disconnect the hall sensor and stator connection 
before removing the stator in the subsequent step. 
26
      
⑤ 
    
Remove the six screws securing the rotor. 
      
⑥ 
    
Check the position of the snap ring, being sure it 
faces the rotor and stator. 
      
⑦ 
    
To keep from dropping the stator, loosen the six 
bolts almost all the way; then hold the stator in one 
hand while removing the bolts with the other. 
      
⑧ 
    
Be careful during removal and replacement to 
avoid cutting, nicking, or pinching any of the wires. 
This could cause a short or electrical noise in the 
machine. 
     
③   
Remove the screws that secure the water guide. 
27
10) Disassembly of Door Lock Switch
        
 
Remove the two door lock attachment screws.
        
② 
Remove the door switch and remove the attachment tube. 
     
⑩  
Remove 17 screws to release the bearing housing. 
Pull the housing away from the tub, but do not pry it 
with a screwdriver to avoid damage. 
     
⑨   
Remove four screws to release the tub bracket.
Bearing Housing
4-2. WIRING DIAGRAM
28
Page of 56
Display