45
Test
point
and
Result
(Hall
Sensor)
- Voltage Testing Hall Sensor from the Main PCB Assembly
1. Unplug power cord.
2. Remove rear panel.
3. Remove Washer Top.
4. Remove Main PCB Assembly cover as shown in Figure below.
5. Locate the Blue Hall Sensor 6 wire connector using wiring diagram wire colors as your guide.
6. Plug in power cord, close door, and press power button. DO NOT  PRESS START!
7.  Place meter leads on White & Gray wires. You should read 10 to 15 Vdc  output from the Main 
PCB Assembly to the Hall sensor. If no 10 to 15 Vdc is  measured the control board is defective.
8.  Place meters leads on Blue to Yellow. Turn motor rotor slowly by hand. You should measure a 
pulsing 10 Vdc. Place meter leads on Red to Yellow. Turn motor rotor slowly by hand. You should 
measure a pulsing 10 Vdc. If both tests measure a pulsing 10 Vdc, hall sensor and harness OK. If 
either or both tests measures 9 to 10 volts, but does not pulse or change, Hall sensor has failed 
and must be replaced. IF zero (0) voltage is measured on either test, check red & blue wires for 
continuity. Repair or replace harness as needed. 
Result
8-12 kΩ
8-12 kΩ
10-15 Vdc
10 Vdc
10 Vdc
Test Points
(1) to (2)
(1) to (3)
(1) to (6)
(2) to (6)
(3) to (6)
Remarks
Voltage Input
Pulsing Signal
Pulsing Signal
(1)
(2)
(3)
(6)
5-4. PUMP MOTOR ASSEMBLY
46
Wiring
diagram
Test 
points
and
Result
Circuit in the MAIN PCB
Wiring Diagram
(1) (2)
Result
10.9 Ω±5%
Remarks
Resistance
Test Points
(1) to (2)
5-5. INLET VALVE ASSEMBLY
47
Wiring
diagram
Function
Test
points
and
Result
Circuit in the MAIN PCB
Wiring diagram
INLET VALVE
Inlet valve driving circuit
Depending on the cycle and water temperature, the controller will energize the hot or cold water 
valve solenoids to meet the selected water temperature.
After unplugging the connector of the defective valve, check the resistance.
(1) (2)
(2)
(2)
(2)
(2)
(1)
(1)
(1)
(1)
* All valves operate at 13.5 VDC.
Test 
Points
(1)-(2)
Result
24±10% [Ω]
5-6. THERMISTOR ASSEMBLY
48
Wiring
diagram
Function
Test
points
Circuit in the MAIN PCB / Wiring Diagram
Wash Thermistor
The thermistor (temperature sensor) is used to monitor water temperature in the tub.
MAIN PCB
(2)
(1)
Page of 55