LG WT-D082WG Service Manual ▷ View online

 
 
4) No water supply 
Check   
Check results 
Possible reasons 
Solution measures 
Inlet valve 
1. Water  is  not  flowing 
into  inner  tub  and 
there  is  current  flow 
though  inlet  valve  is 
working. 
1) Check  if  water  tap  is 
close. 
 
Close   
Close   
Explanation   
2) check  if  the  tap  is 
open 
No   
Use error 
Open water tab 
3)remove  inlet  valve  and  check 
filter  if  problems  are  not 
mentioned above. 
Filter is clogged 
No cleaning 
Use  a  brush  to  clean  the 
filter and filter should be 
cleaned regularly. 
3) check 
whether 
membrane  hole  is 
clogged  with  foreign 
objects  or  piston 
inside  valve  is  locked 
if  problems  are  not 
mentioned above.   
 
Inlet valve fault 
Replace inlet valve   
2. If  inlet  valve  is  not 
working  and  there  is 
no  current  sound 
during water supply. 
1) Check  if  connectors 
are  not  connected  or 
connected unproperly. 
Poor connection 
Connection fault 
Connect 
again 
or 
implement 
troubleshooting caused by 
poor connection. 
2) Check  inlet  valve 
resistance 
Not  between  0 。
8—1。2KΩ 
Coil is cut off 
Replace inlet valve 
Pressure sensor 
1 . If  error  message  “PE”  is 
displayed: sensor fault. 
“PE”error display 
Connectors 
do 
not 
connect or harness, coil is 
cut off. 
Connect  connectors  or 
replace  harness.  If  coil  is 
cut off, replace the sensor.
2.Check  BP  sensor  (pressure 
sensor)  frequency  with  no 
load and no water supply.   
Less than 20KHz 
BP sensor fault 
Replace BP sensor fault
Yes   
 
Replace PC board 
PC board 
1.If inlet valve and sensor have 
no  fault,  check  the  PC 
board. 
 
29
 
 
 
5)
 
Continuous or intermittent water supply 
Check   
Check results 
Possible reasons 
Solution measures 
Incorrect  installation/water 
leakage 
1.Check  if  drain  hose  is 
placed  on  the  floor.(Pump 
model) 
Yes   
Incorrect installation 
Drain  hose  should  be 
hang  over  standpipe  or 
wash tub. Replace parts. 
2.Check leakage place 
Water  leakage  from 
some parts 
Parts fault 
Repair the parts 
Pressure sensor 
1 . Check  if  wave  wheel 
rotates with no water supply. 
No   
No water pressure sensor
Check  if  pressure  sensor 
pipe  is  broken  and  repair 
it. 
2 . Check  if  air  hole  is 
clogged there is no sensor 
fault. 
Yes   
Air hole is clogged 
Repair air hole 
Inlet valve 
1. Is  there  water  supply 
under  no  power(power 
is off)? 
Yes   
Inlet valve fault 
Replace inlet valve 
PC board 
1.Press “POWER” and there 
is 
water 
supply 
immediately 
before 
“START/PAUSE” 
pressed. 
 
Short-circuit of controlled 
silicon   
Replace PC board 
 
30
 
 
 
6) Display “LE” and out of work 
Check   
Check results 
Possible reasons 
Solution measures 
1.Check connectors 
Poor connection 
Connection fault 
Connect 
again 
or 
implement 
troubleshooting caused by 
poor connection. 
2.Check rotor magnet 
Cracked   
 
Replace rotor 
3.Measure  if  resistance 
between two legs of stator 
connector  is  between 
5—15Ω. 
Yes 
No 
None 
Stator fault 
 
Replace stator 
Normal 
Abnormal   
None   
Hall element fault 
 
4.Check Hall element   
Replace Hall element 
5.It  must  be  PC  board 
fault  if  fault  is  not 
mentioned above. 
 
 
Replace PC board 
 
7) Power failure 
Check   
Check results 
Possible reasons 
Solution measures 
Main voltage 
Input  voltage is  abnormal 
caused by interference. 
 
Input voltage fault 
Explanation 
(  high-frequency  device 
around washer) 
Automatic power relay or 
PC board 
1. Check  if  power  is 
off  automatically  when 
unplugging  power  cord 
during power is on. 
2. There  must  be  PC 
board fault if power is off 
immediately  when  power 
is on and power switch is 
under good condition.     
 
 
 
 
Power 
is 
cut 
off 
immediately. 
Power switch fault 
 
 
Replace PC board 
31
 
 
 
8) Undrained 
Check   
Check results 
Possible reasons 
Solution measures 
Drain motor 
 
Yes 
 
Clogged  with  foreign 
objects 
 
1 . Check  if  there  is 
working sound of drain 
motor. 
Unplug  drain  valve  and 
remove foreign objects 
2.Measure  resistance  if 
there  is  no  working 
sound 
∞ 
Drain motor coil is cut off
Replace drain motor 
Connector fault 
Connector fault 
Repair connector 
3 . Check  connectors  if 
there is no working sound 
and resistance is normal. 
No Connector fault 
PC board fault 
Replace PC board 
Drain hose 
 
Winded   
 
Installation problem 
 
Install  it  again  to  avoid 
winding   
1.Check  if  the  space  is 
too  small  to  place 
drain hose or hose is 
winded 
2.Check if drain hose is 
folded  or  clogged 
with foreign objects.
Clogged   
Drain hose is clogged 
Remove foreign objects or 
install it again to avoid 
winding. 
 
9) Drain out of drainage time 
Check   
Check results 
Possible reasons 
Solution measures 
 
Clogged  with  foreign 
objects 
 
 
 
Remove foreign objects 
Drain valve shell 
1.Check whether rubber 
bellows  are  deformed 
or  there  are  foreign 
objects  in  drain  valve 
components  if  keeping 
draining.   
Deformation  of  rubber 
bellows 
Deformation  of  rubber 
bellows 
Replace rubber bellows 
PC board 
1.Check if drain motor or 
drain  pump  runs 
immediately 
when 
power is on. 
 
Yes 
PC board fault 
 
Replace PC board 
 
Drain hose 
1.Check if drain hose is 
properly  installed.  The 
discharge  height  should 
be 
less than
6 cm
 from the floor.   
More
  than suggested  height
Incorrect installation 
 
Place  the  outlet  of  drain 
hose  less than 6 cm
 
from
 
the floor.
32
 
Page of 37
Display