Where, what & how to check?
Result of Check
Possible Cause How to repair & settle
Drain Motor
(For Non-Pump Model only)
1. Check resistance of the drain 
motor if it can not pull the PV link.
∞ Ω
Resistance is 
normal.
Drain  motor  coil  is
open.
Contact defect in 
connection parts 
or defect of the 
controller.
Change the drain motor 
→Check the washer 
works normally after 
reassembling.
(PV link & drain motor 
lever should be
assembled accurately.)
Change the controller if 
there is no defects in the
connection parts.
8) Water drains though it is not the time of drain.
Where, what & how to check?
Result of Check
Possible Cause How to repair & settle
Drain Motor
(for Non-Pump Model only)
1. Check whether the drain motor is 
normally returned after turning 
power off.
(It is considered normal if the lever 
of the drain motor is fully pulled out 
by the PV spring)
PV Case
1. If water drains though the drain 
motor is normally returned, check 
whether PV asm is blocked by 
foreign objects or the bellows in 
the PV asm is deformed.
Controller
1. Check whether the drain motor or 
the drain pump works immediately
after power is turned on.
Blocked.
Blocked.
Bellows
deformed.
Works. 
Defect of the drain
motor.
Defect of PV 
Bellows.
Defect of the 
controller(Triac 
defect)
Drain Hose
1. Check whether the drain hose is
installed properly so that the
discharge hight is about
0.9~1.2m from the floor.
The discharge
height is lower
than
recommendation.
Wrong installation
of the drain hose.
Put the outlet of drain
hose between 0.9m and
1.2m
Change the drain motor.
Remove the objects in 
the PV asm.
Change the PV bellows.
(The bellows may swell 
up if it contact petroleum
or petrochemical 
substance because it is 
made of rubber)
Change the controller.
49
10) Spining is going on even though the lid is open.
Where, what & how to check?
Result of Check
Possible Cause How to repair & settle
Lid Switch 
1. Check resistance between both 
terminals of the lid switch with 
the lid open.
0~9
∞ Ω
Contact points of
the lid switch is
welded.
Defect of the 
controller.
Change the lead wire
assembly.
Change the controller.
11) Vibration, Noise or Unbalance Error happens during spin.
Where, what & how to check?
Result of Check
Possible Cause How to repair & settle
Using conditions such as
 installation etc.
1. Check whether the washer is 
leveled. (Check clearance with out
tub and out case the left gap is the
same as the right and the rear gap is 
1.5~2 time bigger than the front gap, 
between the cabinet and the wash 
bowl, when it is leveled.)
2. Check whether laundry in the wash 
bowl is out of balance that can 
cause severe vibration & noise.
3. Check whether the puisator doesn’t 
rotate during spin.(To check that, 
remove the front lid and than run the
spin only cycle.)
Not leveled.
Laundry is 
unbalanced.
The pulsator 
rotates initially 
then the inner tub
rotates.
Defect of 
installation
Defect of the 
clutch
Level the washer.
Explain that it is not out
of order and it may
happen when big & long
laundry is washed.
Change the clutch 
spring-B or the clutch 
asm.
9) Drain error happens while water drains normally.
Where, what & how to check?
Result of Check
Possible Cause How to repair & settle
Pressure Switch
1. Check generation frequency of the 
pressure switch without water.
Less than
26.3 kHz
26.3~27.1 kHz
Defect of the 
pressure switch.
Defect of the 
controller.
Change  the  pressure
switch.
Change the controller.
50
12) Power is automatically turned off during operation or
immediately turning on the power button.
Where, what & how to check?
Result of Check
Possible Cause
How to repair & settle
Mains voltage
1. It is mostly caused by noise from
mains or transient power cut.
Auto Power Relay or Controller
1.Check whether power is
automatically turned off when turning
on the power switch after unplugging
the power cord from the outlet.
2. It would be defect of the
controller if power is
automatically tumed off 
immediately when turning on the
power switch even though there
is no defects in the power switch.
Automatically 
tumed off
Defect in mains
Mechanical
defect of the
power switch
Explain the cause 
(It happens specially
when a high
frequency 
equipment is a used 
around the washer or 
in the case voltage 
fluctuation is big.)
Change the switch.
Change the controller.
11) Vibration, Noise or Unbalance Error happens during spin.
Where, what & how to check?
Result of Check
Possible Cause How to repair & settle
Suspension
1. Check whether the outer tub cover 
hit the top cover without load
during spin. 
Hit
Defect of the
Suspension
Change four 
suspensions
simultaneously.
(In assembling, check
the position to 
suspension asm)
※ It is very important to find out what kinds of noise & where comes from to settle
noise during spin and accumulately service experiance.
51
TITLE
5. EXPLODED VIEW
BODY-A
BODY-B
TUB
Page of 61
Display

Click on the first or last page to see other WT-101N / WT-R101767TCHP / WT-Y142X / WT-Y132G / WT-Y122G / WT-Y122X / WT-Y122S service manuals if exist.