DOWNLOAD LG WP-1350RS Service Manual ↓ Size: 5.22 MB | Pages: 27 in PDF or view online for FREE

Model
WP-1350RS
Pages
27
Size
5.22 MB
Type
PDF
Document
Service Manual
Brand
Device
Washing Machine
File
wp-1350rs.pdf
Date

LG WP-1350RS Service Manual ▷ View online

-10-
Fig. 28
Fig. 29
Fig. 32
Fig. 30
Fig. 31
Lower bolt
Fig. 27
10. Loosen the fixing bolt fastening the motor shaft
and pull up the coupling assembly(Fig. 27).
2. Disconnect the lead wires.
3. Lay the washing machine on its front side on a
blanket or cardboard.
4. Remove the screws fastening the base and remove
the base from the outcase(Fig. 30).
5. Remove the screws and the washers, remove the
wash motor and remove the wash motor
damper(Fig. 31).
6. Loosen the socket bolt of the motor pulley
assembly and pull up the motor pulley assembly
from the motor.
To assemble the wash motor, reverse disassembly
procedure.
11. Remove the screws fastening the brake assembly
and remove the brake assembly(Fig. 28).
To assemble the spin motor, reverse the disassembly
procedure.
After removing the back cover and the spin dryer
basket, proceed as follows:
1. Remove the V-belt from the pulsator pulley(Fig. 29).
4-5. Wash Motor Replacement
-11-
4-6. Washing Tub Assembly
replacement
After removing the panel assembly, the safety cover
assembly, the spin dryer basket assembly, the spin
dryer cover, the washing cover, the Q-spring, the
nozzle case, the door switch and the back cover,
proceed as follows:
1. Disconnect the drain hose or the drain hose-D
(Pump model).
2. Remove the V-belt from the pulsator pulley(Fig. 29).
4-7. Gear Case Assembly
replacement
After removing the back cover and opening the
washing cover, proceed as follows:
1. Take out the pulsator cap with "-" type driver.
2. Loosen the pulsator fixing screw and pull up the
pulsator(Fig. 36).
3. Remove the V-belt(Fig. 29).
4. Lay the washing machine on its front side on a
blanket or some cardboard.
5. Unscrew and remove the screws fastening the base
and remove the base assembly(Fig. 37).
Fig. 36
Fig. 37
Fig. 33
3. Unscrew and remove the screws fasting the spin
dryer cover guide.(Fig. 33)
4. Remove the spin dryer cover guide from the tub.
(Fig. 33)
5. Unscrew the screws on both sides and pull off the
front panel.(Fig. 34)
6. Remove the screws on the front and the rare 
and pul it out.(Fig. 35)
Fig. 34
Fig. 35
-12-
Nut
6. Unscrew the pulsator pulley fixing bolt, the nut,
remove the pulsator pulley (Fig. 38)
7. Unscrew and remove the screws fastening the gear
case assembly at the tub(Fig. 39).
To assemble the gearcase assembly to the tub,
reverse the above disassembly.
After removing the spin dryer basket assembly, refer
to the figures and proceed as follows:
1. Remove the bellows assembly(Fig. 41).
2. Remove the bellows supporter by using slip joint
pliers to the spin tub bottom(Fig. 41).
Bellows assembly
The assembly procedure is as follows:
1. Insert the bellows assembly into the bellows
supporter(Fig. 42).
2. Fit them by pushing the bellows assembly and the
bellows supporter at the same time in the spin tub
bottom(Fig. 42).
3. Pass the spin shaft through the center hole of the
bellows assembly and insert it into the coupling
assembly(Fig. 42).
NOTE
1. Don't disassemble three screws fixing the
gear case assembly.
2. Check the assembled condition of the
packing-P at the tub hole is right when you
assembled the gear case assembly(Fig. 40).
NOTE
The bellows assembly attached to the unit
cannot be removed unless it is torn off.
Tub
Packing-P
Gear case
4-8. Bellows Assembly Replacement
Fig. 38
Fig.39
Fig. 40
Fig. 41
Fig. 42
-13-
4. Tighten the bolt of the coupling assembly while
adjusting it to the cutter split made in the spin
shaft(Fig. 43).
2. Untighten the plunger valve cover by rotating in the
direction of the arrow(Fig. 45).
Plunger valve
cover
3. Remove the plunger valve spring, the plunger valve
rod and the plunger valve bellows(Fig. 46).
To assemble the plunger valve assembly, reverse the
disassembly procedure.
Cover
Spring
Bellows
NOTE
If water leakage occurs at the spin tub after
assembling the bellows assembly and the
bellows supporter, it is wrong. It could cause
an electrical shock or a fire, therefore they
should be securely assembled again.
NOTE
• Damage to the plunger valve cover may
cause water leakage.
• When replacing the plunger valve assembly,
take care not to cause water leakage.
4-9. Plunger Valve Assembly
replacement
After removing the back cover and setting the knob
for the drain selector to "WASH - RINSE", proceed as
follows:
1. Disconnect the plunger valve strap from the
plunger valve rod(Fig. 44).
Fig. 43
Fig. 44
Fig. 45
Fig. 46
Page of 27