LG WM3988HMA / WM3988HWA Service Manual ▷ View online
28
DOOR OPEN ERROR
Is displayed?
Yes
Is the connector connected
to door switch or main PWB
disconnected?
to door switch or main PWB
disconnected?
Reconnect or
repair
the connector
repair
the connector
Yes
No
Is there clicking sound once
or twice when the
START/PAUSE button is
pressed to start the cycle?
or twice when the
START/PAUSE button is
pressed to start the cycle?
Replace the
PCB
ASSEMBLY.
PCB
ASSEMBLY.
No
Is DOOR SWITCH
ASSEMBLY broken?
ASSEMBLY broken?
Replace the
DOOR
SWITCH
ASSEMBLY.
DOOR
SWITCH
ASSEMBLY.
No
Yes
Does the spring of Latch
Hook actuate?
Hook actuate?
Replace
Door
Assembly
Door
Assembly
Yes
No
[Note] Environmental check list
1) The machine must operate with all the doors
1) The machine must operate with all the doors
completely closed and locked.
2) The washing area must operate with a water
temperature not higher than 45 Celsius and
must not have more amount of supplied water
than it should.
must not have more amount of supplied water
than it should.
29
UNBALANCE ERROR
OVER FLOW ERROR
[Note] Environmental check list
1) Removal of transportation-based fixed bolt.
2) Confirmation on the material to see if it is capable
1) Removal of transportation-based fixed bolt.
2) Confirmation on the material to see if it is capable
of handling two different types of blanket materials.
Is displayed?
Yes
Does the laundry lean
toward one side, not evenly
put in the DRUM assembly?
toward one side, not evenly
put in the DRUM assembly?
Put laundry
evenly
In the DRUM
assembly
evenly
In the DRUM
assembly
Yes
Is the washing machine
installed at an angle?
installed at an angle?
Adjust the
height of
washing
machine
to be kept
horizontally
height of
washing
machine
to be kept
horizontally
Yes
No
Is displayed?
Yes
When you press both
WASH/RINSE button and
SOIL LEVEL button
simultaneously, is the
water level frequency over
21.3kHz?
WASH/RINSE button and
SOIL LEVEL button
simultaneously, is the
water level frequency over
21.3kHz?
(Refer to 7-4)
Check the AIR
CHAMBER
and the tube
(clogged).
CHAMBER
and the tube
(clogged).
No
Does the inlet valve work
when the power is not
applied?
when the power is not
applied?
Replace the
INLET VALVE ASSEMBLY
INLET VALVE ASSEMBLY
If the inlet
valve work
continuously
when the power
is applied,
Replace the
MAIN PWB
ASSEMBLY
valve work
continuously
when the power
is applied,
Replace the
MAIN PWB
ASSEMBLY
No
Yes
Yes
30
PRESSURE SENSOR ERROR
Is displayed?
Yes
Is the connector connected
to pressure sensor
disconnected or
disassembled?
to pressure sensor
disconnected or
disassembled?
Reconnect or
repair
the connector
repair
the connector
No
No
Yes
Is the resistance of the
pressure sensor out of
range?
(pin 1~ pin 3)
(21~23
pressure sensor out of
range?
(pin 1~ pin 3)
(21~23
Ω ±10%)
Replace the
pressure
switch
pressure
switch
No
Yes
Is the AIR CHAMBER and
the tube clogged?
the tube clogged?
Replace the MAIN PWB
assembly.
assembly.
Fix the air
chamber
and remove
the foreign
material.
chamber
and remove
the foreign
material.
Yes
31
DRY HEATING ERROR
Is displayed?
Is the connector connected
to thermistor disconnected
or disassembled?
to thermistor disconnected
or disassembled?
Reconnect or
repair the
connector
repair the
connector
Yes
Yes
Is thermistor resistance out
of range?
(about 39.5 k
of range?
(about 39.5 k
Ω ⁄ at 30
°C
)
(Refer to 9-7 thermistor
assembly)
assembly)
Replace the
THERMISTOR
ASSEMBLY
THERMISTOR
ASSEMBLY
Yes
Check the trans of water
infiltration into thermistor
terminal.
- Does the water infiltrate
infiltration into thermistor
terminal.
- Does the water infiltrate
thermistor terminal?
Replace the
THERMISTOR
ASSEMBLY
THERMISTOR
ASSEMBLY
Yes
Is the connector connected to
FAN MOTOR disconnected or
disassembled?
FAN MOTOR disconnected or
disassembled?
Reconnect or
repair the
connector.
repair the
connector.
Yes
Yes
Replace the
MAIN PWB
assembly
MAIN PWB
assembly
Is the voltage of the Fan motor
connector 20~30 V DC?
(Check the all terminal of
FAN MOTOR Assembly
while the machine is dry
course.)
connector 20~30 V DC?
(Check the all terminal of
FAN MOTOR Assembly
while the machine is dry
course.)
In case of measuring by
multimeter (multitester)
: 0~20V
multimeter (multitester)
: 0~20V
No
No
Is the connector connected
to heater disconnected or
disassembled?
to heater disconnected or
disassembled?
Reconnect or
repair the
connector
repair the
connector
Continued next page
Yes
No
Yes
Is the resistance values in
the range of 2 to 5
the range of 2 to 5
Ω?
(pin1-pin3, pin2-pin3)
- After pull out the YL1
- After pull out the YL1
connector, check the
terminal of the connector in
wire.(Yellow 3P, male)
terminal of the connector in
wire.(Yellow 3P, male)
Replace the
FAN Motor
Assembly
FAN Motor
Assembly
No
No
No
No
Click on the first or last page to see other WM3988HMA / WM3988HWA service manuals if exist.