40
Test Point 
and 
Result 
(Hall 
Sensor)
1. Unplug power cord.
2. Remove rear panel.
3. Remove Washer Top.
4. Remove Main PCB Assembly cover as shown in Figure below.
5. Locate the white Hall Sensor 4 wire connector using wiring diagram wire colors
as your guide.
6. Plug in power cord, close door, and press power button. DO NOT PRESS
START!
7. Place meter leads on White & Gray wires. You should read 10 to 15 Vdc output
from the Main PCB Assembly to the Hall sensor. If no 10 to 15 Vdc is
measured the control board is defective.
8. Place meters leads on Blue to Gray. Turn motor rotor slowly by hand. You
should measure a pulsing 10 Vdc. Place meter leads on Red to Gray. Turn
motor rotor slowly by hand. You should measure a pulsing 10 Vdc. If both tests
measure a pulsing 10 Vdc, hall sensor and harness OK. If either or both tests
measures 9 to 10 volts, but does not pulse or change, Hall sensor has failed
and must be replaced. IF zero (0) voltage is measured on either test, check red
& blue wires for continuity. Repair or replace harness as needed.
- Voltage Testing Hall Sensor from the Main PCB Assembly
7. To measure output signal voltage from the hall sensor, carefully move test
leads to terminals 1 to 4, blue and gray. Slowly rotate motor rotor by hand. 
You should read a pulsing 10 Vdc. If 10 Vdc is measured from 1 to 4, move
lead on blue wire to red wire, terminal 2. Repeat rotating motor rotor by hand.
You should read a pulsing 10 Vdc from red to gray.
8. If pulsing 10 Vdc is measured from 1 to 4 and 2 to 4, hall sensor is OK! If either
test netted only 9 to 10 Vdc without changing (no pulsing) the hall sensor is
likely defective. Disconnect power by unplugging washer and ohm check hall
sensor to verify failure of the hall sensor.
Test Points
(1) to (2)
(1) to (3)
(1) to (4)
(2) to (4)
(3) to (4)
Result
8-12 k
8-12 k
10-15 Vdc
10 Vdc
10 Vdc
Remarks
Voltage Input
Pulsing Signal
Pulsing Signal
(2) (1)
(4) (3)
41
9-4. PUMP MOTOR ASSEMBLY
Wiring
diagram
Circuit in the MAIN PWB
Wiring Diagram
MICOM
IC
R
5V
Rg
Cg
Vdc
Rs
Cs
PCB
CONNECTOR
PUMP
Vac
2
1
4
3
Pump Driving circuit
MAIN PWB
BL4
1 2 3
1
2
3
3 2 1
3 2 1
1
2
3
4
1 2 3 4
BL3
SB
BK
BN
DRAIN
PUMP
Object
Function
Test
points
Result
* Each circuits of loads in wiring diagram are all same.
Two pump motors are used to drain the tub and to circulate the water / detergent solution.
Drain Pump
Drain Pump
Test Points
Result
(1) to (2)
10-20 
T.P
For Drain
(1)(2)
(1)
(2)
42
9-5. INLET VALVE ASSEMBLY
Wiring
diagram
Circuit in the MAIN PWB
INLET
VALVE
Vac
Rs
Vdc
Cg
Rg
IC
MICOM
Cs
PCB
CONNECTOR
Inlet valve driving circuit
Function
Test
points 
and 
Result
Depending on the cycle and water temperature, the controller will energize the hot or cold
water valve solenoids to meet the selected water temperature.
After pull out the connector of defective valve, check the resistance.
Test points
(1)-(2)
Result
0.8-1.2 k
Wiring Diagram
MAIN
WASH
PRE
WASH
BLEACH
HOT
VALVE
1
2
1
2
1
2
1
2 RD
BL
BL
NA
WH
NA4
GY VT
BL
BL4
BL3
4
3
2
1
1
2
3
1
2
3
4
3
2
1
4
3
2
1
4
3
2
1
COMMON
(BK)
MIAN PWB
INLET VALVE
* Each circuits of loads in wiring diagram are all same.
(1) (2)
(1) (2)
(1) (2)
(1) (2)
43
9-6. THERMISTOR ASSEMBLY
Wiring
diagram
Circuit in the MAIN PWB / Wiring Diagram
MAIN PWB
MICOM
NA3
BL
WH
1
2
WASH
THERMISTOR
3
4
5
6
1
5V
5V
R
R
R
R
C
C
C
C
2
3
4
5
6
Function
Test
points
The thermistor (temperature sensor) is used to monitor water temperature in the tub
or Steam Generator.
Wash Thermistor
Test
Points
(1)
to
(2)
Result
(tolerance ±5%)
39.5 k
26.1 k
12.1 k
8.5 k
3.8 k
2.8 k
Remarks
At 86°F (30°C)
At 104°F (40°C)
At 140°F (60°C)
At 158°F (70°C)
At 203°F (95°C)
At 221°F (105°C)
(1) (2)