DOWNLOAD LG WDA81456YC Service Manual ↓ Size: 11.66 MB | Pages: 63 in PDF or view online for FREE

Model
WDA81456YC
Pages
63
Size
11.66 MB
Type
PDF
Document
Service Manual
Brand
Device
Washing Machine
File
wda81456yc.pdf
Date

LG WDA81456YC Service Manual ▷ View online

53
VALVE     (STEAM) 
VALVE     (PRE-WASH)
VALVE     (NORMAL-WASH)
1 Disconnect the wiring connector.
1
1
2
3
2 Remove the valve by two screws of the valve
holder.
• Rating : 220/240V 50/60Hz
• Resistant : 3.5~4.5kΩ
2
When reconnecting the connector
1 Open the door completely.
2 Remove the three screws from the hinge.
When removing the Door Assembly, it is
necessary to hold the Bracket that is inner of
the Cabinet Cover.
First, prepare a bucket to put in the remained
water.
Pull it out from hose.
VIOLET/BLACK-BLACK
WHITE/BLACK-BLACK
GRAY/BLACK
INLET VALVE
3
DOOR
Removing method of remained water
CAP(REMAING HOSE)
54
2 Push out PANEL ASSEMBLY, CONTROL after
Push the hook(     ,     ) below.
2
1
1 The plate assembly(Top) is disassembled.
2 Pull out the drawer and unscrew 2 screws.
1 Two screws are unscrewed.
3 Unscrew the screws from the lower cover.
2 Disassembly lower cover assembly.
3 Unscrew the screw from the CABINET COVER.
1
2
3 Lift the side the Control Panel Assembly and
pull it out
CABINET COVER
Two screws are unscrewed
Pull the drawer to arrow direction.
Screws
Disassembly 3 connectors.
55
• Just check cut-off.
• Check the operating time.
* Door Locking time : 
1~8
sec.
Check the time between from
input the power to parts
move up, then Door locked.
* Door Releasing time : 
25~100
sec.
Check the time between from off
the power to parts
move down, then Door released.
1
1
1
1
2
4 Lift and separate the cabinet cover.
1 Two screws are unscrewed and disassembly
cabinet cover.
2 The Door Lock S/W is disconnected form the
wiring connector and the strap.
NOTE
: When assembling the CABINET
COVER, connect the Door S/W connector.
SWITCH ASSY, DOOR LOCK
56
• V ~ U (8~11Ω)
• U ~ W (8~11Ω)
• W ~ V (8~11Ω)
Motor Stator
U V W
Hall Sensor
Ha
Hb
Common
• Common ~ Ha (5~15kΩ)
• Common ~ Hb (5~15kΩ)
1 Remove the back cover.
2 After loosening the bolt, Rotor, pull out the
rotor.
1 Remove the 6  bolts from the stator.
2 Disconnect the 2 connectors.
1 Remove the hinges (Damper) at the Tub.
3 The hinge at the base is pulled off. 
(In directions  of the arrow)
2 The Hinge(Damper) at the base is  pulled off by
pressing on the snaps at the sharp end.
ROTOR ASSEMBLY, STATOR ASSEMBLY, FRICTION DAMPER
Page of 63
Display

Click on the first or last page to see other WDA81456YC service manuals if exist.