DOWNLOAD LG WD-R1112 Service Manual ↓ Size: 4.48 MB | Pages: 42 in PDF or view online for FREE

Model
WD-R1112
Pages
42
Size
4.48 MB
Type
PDF
Document
Service Manual
Brand
Device
Washing Machine
File
wd-r1112.pdf
Date

LG WD-R1112 Service Manual ▷ View online

14
7-4. ERROR DISPLAY
If you press the Start/Pause button when an error is displayed, any error except 
d
ewill disappear
and the machine will go into the pause status.
In case of 
d
e,
d
e,
d
eif the error is not resolved within 20 sec., or in the case of other errors,
if the error is not resolved within 4 min., power will be turned off automatically and the error code will
blink. In the case of 
d
e, power will not be turned off.
ERROR SYMPTOM
CAUSE
WATER INLET
ERROR
• Correct water level (246) is not reached within 8 minutes
after water is supplied or it does not reach the preset water
level within 25 minutes.
• The load is too small.
• The appliance is tilted.
• Laundry is gathered to one side.
• Non distributable items are put into the drum.
1
2
IMBALANCE
ERROR
• Not fully drained within 10 minutes.
3
DRAIN
ERROR
• Water is overflowing (water level frequency is over 213).
※ If               is displayed, the drain pump will operate to
drain the water automatically.
4
OVER FLOW
ERROR
• The SENSOR SWITCH ASSEMBLY is out of order.
5
PRESSURE
SENSOR 
ERROR
• Door not all the way closed.
• Loose electrical connections at Door switch and 
PWB Assembly.
• The DOOR SWITCH ASSEMBLY is out of order.
6
DOOR OPEN
ERROR
• The THERMISTOR is out order.
7
HEATING
ERROR
ERROR
SYMPTOM CAUSE
8
9
10
• MAIN PWB ASSEMBLY is out of order
Replace the MAIN PWB ASSEMBLY
• Winding in the STATOR ASSEMBLY is short-circuited.
Replace the STATOR ASSEMBLY
• “      ” is dispplayed during a high spin 
Replace the LEAD WIRE ASSEMBLY (MOTOR)
• The connector in the LEAD WIRE ASSEMBLY is not connected to
the connnector of STATOR ASSEMBLY
Reconnect or repair the connector
• The hall sensor is out of order/defective.
Replace the STATOR ASSEMBLY
• The Dry Heater is out of order
Replace the Dry Heater
• The Connector of the Dry Heater is not connected properly to the
connector in the Main PWB ASSEMBLY
Reconnect or repair the connector
• The Dry fan motor is out of order
Replace the fan Motor.
CURRENT
ERROR
MOTOR
ERROR
DRY
HEATOR
ERROR
15
16
8-1. DIAGNOSIS AND SOLUTION FOR ABNORMAL OPERATION
8. ERROR DIAGNOSIS AND CHECKLIST
SYMPTOM
GUIDE FOR SERVICE CALL
NO POWER 
Water inlet trouble
YES
YES
YES
NO
NO
YES
NO
NO
Is the power plug connected firmly to 
120V~ outlet?
Power failure? or Breaker opened?
Visit to check 
Is "       " displayed?
Is the tap opened?
Is the tap frozen?
Is the water supply shut-off?
Is filter in the inlet valve clogged with
foreign material?
Visit to check 
Clean the filter of
inlet valve
17
SYMPTOM
• Door does not open
• Error displayed on
   the program
• DRAIN TROUBLE
GUIDE FOR SERVICE CALL
NO
YES
NO
YES
Started with door opened?
NO
YES
Is the drain pump filter clogged with foreign 
material such as pin, coin and etc.?
Is the drain hose frozen with water,  
kinked or crushed?
Visit to check 
Close the door
Visit to check
Check if the door switch is O K.
Is "       " displayed?
Clean up
the filter.
.
Page of 42
Display

Click on the first or last page to see other WD-R1112 service manuals if exist.