LG WD-CD906SM / WD-CD1006SM Service Manual ▷ View online
33
Disassemble the Hall Sensor
1) Disassemble the hook of Hall Sensor by (-) driver.
2) Pull up Hall Sensor slowly as shown in picture.
1) Adjust the hole of Hall Sensor to
the hooks of stator as shown in red circle
2) Push down the Hall sensor,
and assemble to the hook securely.
Caution
If you disassemble by force,not following the directions,
the hooks of stator(red circled) might break.
Hence need change of stator assembly.
the hooks of stator(red circled) might break.
Hence need change of stator assembly.
So disassemble cautiously.
1
Assemble the Hall Sensor
2
[Note]
Hall Sensor Part No.
• 24” / 25” : 6501KW2001A
• 24” / 25” : 6501KW2001A
• 27” : 6501KW2002A
34
Dry Heater Error (dHE)
Is the
Connector
connected correctly to
the
Main PCB
and the
Dry Heater or Fan Motor
?
Or is the
Harness
alright?
Reconnect or repair the
Connector
.
Or replace the
Harness
.
Clean the
Bellows
.
Replace the
Thermistor
.
Is the resistance of t.he
Thermistor
out of range
2.5 ~ 180KΩ at 105 ~ 0°C?
YES
Disassemble the
Cabinet cover
and
Condensing Bellows.
Is there any foreign object in
Condensing Bellows
?
Disassemble the
Dry Fan Assy and Dry Duct Upper,
and clean foreign object in
Duct and Fan
.
Check for
Dry Heater
trouble.
Page 38
Check for
Dry Fan Motor
trouble.
Page 39
YES
NO
NO
NO
YES
35
Dry Heater Trouble
After power off, is the resistance of
Dry Heater
out of
range 33 ~ 37Ω?
Is
Thermostat
closed ?
When checking voltage between
connectors(1,2)
on drying, is the voltage AC 220-240V as the figure ?
YES
YES
Replace the
Dry Heater
.
NO
Replace the
Thermostat
.
NO
Replace the
PWB assembly (main)
.
NO
36
Dry Fan Motor Trouble
Is the
Connector
connected correctly to
the
Main PCB
and the
Dry Heater
or
Fan Motor
?
Or is the
Harness
alright?
Are the resistance same between
terminal
points?
V~U / U~W / W~V : 2~5Ω
When checking voltage between
connectors(1,2)
on drying, is the voltage DC 20~30V as the figure ?
YES
YES
Reconnect or repair the
Connector
.
Or replace the
Harness
.
NO
Replace the
Dry Fan Motor
.
NO
Replace the
PWB assembly
(main)
.
NO
V U W
Click on the first or last page to see other WD-CD906SM / WD-CD1006SM service manuals if exist.