2-2.DETERMINE WASHING TIME BY FUZZY LOGIC
To get the best washing performance optimal time is determined by sensing of water temperature, 
selected washing temperature and laundry amount.
2-3.WATER LEVEL CONTROL
● This model adopts a pressure sensor which can sense the water level in the tub.
● When the water level reaches to the preset level the water supply is stopped, then the washing program proceeds.
● Spinning does not proceed until the water in the tub reduces a certain level.
2-4.THE DOOR CAN NOT BE OPENED
While program is operating.
While Door Lock light turns on.
5
FUZZY
LOGIC
laundry
amount
selected
washing
temperature
water
temperature
washing time
rinse time
spin rhythm, time
the best
washing
performance
SENSING
PROCESSING
DETERMINATION
EFFECT
3. PARTS IDENTIFICATION
6
Synthetic
Wool
Hand W
ash
Drain
Quick30
Rinse+Sp
in
■ACCESSORIES
1⃞ Before servicing ask the customer what the trouble is.
2⃞ Check the adjustments. (Power supply :220-240V~, Removal of transit bolts etc..)
3⃞ Check the troubles referring to the troubleshooting.
4⃞ Decide service steps referring to disassembly  instructions.
5⃞ Then, service and repair.
6⃞ After servicing, operate the appliance to see whether it works O·K or NOT.
■ STANDARD INSTALLATION
The appliance should be installed as follows.
REMOVE THE TRANSIT 
INSTALL THE  APPLIANCE
ADJUST THE 
BOLTS
ON FLAT AND FIRM SURFACE
HORIZONTAL
Remove the transit bolts
Turn the adjustable feet to
(4EA:
①) with supplied wrench. 
set the appliance horizontally.
Keep the transit bolts and  
wrench for future use.
Insert the 4 caps provided 
into the hole.
The appliance goes up by 
rotating the feet clockwise. 
The appliance comes down by
rotating the feet counter-
clockwise.
4. INSTALLATION 
7
1
High
Low
■ HOW TO CONNECT INLET HOSE
Check that the rubber is the inside of valve connector.
Connect inlet hoses firmly to prevent leak.
■ CONNECT DRAIN HOSE
■ CONNECT POWER PLUG
8   
· Make sure that the hose is not twisted.
※ The drain hose should be placed under 100cm from the floor.
· Connect the power plug to the wall outlet.
· Avoid connecting several electric devices, 
It may be the cause of a fire.
· Avoid submerging the end of the hose.