LG WD-12180TDS / WD-14180TDS Service Manual ▷ View online
2
4
Water Outlet Error (OE)
Is the drain hose kinked ?
Check drain hose for kink and straighten the
Hose
.
Drain Hose
Is the
Pump filter
clogged ?
Next Page
Check & Clean
Pump Filter
.
YES
YES
NO
NO
This kind of accumulation on the drain filter not only
prevents proper drainage, but also will promote
bacteria growth and cause odors.
This drain filter should be cleaned once a month.
prevents proper drainage, but also will promote
bacteria growth and cause odors.
This drain filter should be cleaned once a month.
* How to disassemble and clean pump filter
Open the Cover by coin or
finger(only new model)
Cover
Drain water by removing the
hose cap.
Disassemble the pump
filter by turning the filter
cap counterclockwise.
Filter clogged by foreign objects
Assemble & close cap
Pump Filter
filter Cap
Hose Cap
Clean the filter
Filter Cap
2
5
Is the
Connector
connected correctly to
the
Main PCB
and the
Pump Motor
?
Or is the
Harness
alright ?
Is the
Standpipe Height
greater
than 1.0 m above the floor?
When there is not water in the
pump casing, is the water level
frequency over 26.2KHz ?
Observe
Standpipe Height
requirements
of
1.0
m maximum.
- Your washer will not be able to drain out
water adequately, if the standpipe exceeds 1.0 m.
In this case, water may flow back into the washer.
Check the
Air Chamber
and the
Tube
(clogged).
And When you check the water level frequency
again, if it is over 25.5KHz, you replace the
Pressure switch
.
YES
NO
Reconnect or repair the
Connector
.
Or replace the
Harness
.
NO
Replace the
Main PCB
.
NO
Replace the
Pump Motor
.
Is the resistance of the Pump Motor out
of 152 ~ 175Ω?
Or is the Impeller operating normally?
Or is the Impeller operating normally?
Is Pump motor started, when the spin mode is
started ?
Escape
Binding
NO
NO
YES
YES
OR
YES
2
7
Is the air chamber and the tube clogged?
Replace the
Main PCB
.
Is the
Connector
connected correctly to
the
Main PCB
and the
Pressure Switch
?
Or is the
Harness
alright ?
Reconnect or repair the
Connector
.
Or replace the
Harness
.
Check air chamber and remove the foreign material.
Replace the
Pressure Switch
.
YES
YES
NO
Is the resistance of the
Pressure Switch
out of range?
[Pin1 ~ Pin3]
21~23Ω)
NO
NO
YES
Pressure Sensor S/W Error (PE)
Click on the first or last page to see other WD-12180TDS / WD-14180TDS service manuals if exist.