LG WD-1090FHB / WD-1098FHB Service Manual ▷ View online
20
NO
YES
NO
NO
YES
NO
YES
YES
NO
NO
YES
YES
YES
NO
NO
NO
YES
Wiring diagram
HOT
HOT
Is the water supply shut-off?
Is the tap opened?
When you press both Spin button and Temp.
buttons simultaneously, is the water level frequency
below 240?
buttons simultaneously, is the water level frequency
below 240?
Is the inlet valve filter clogged with impurity?
Is resistance of the inlet valve connector
between the 2 to 8
between the 2 to 8
kΩ
?
Check the voltage between each terminals of inlet
Valve is 220 - 240V~.
(Refer to 7-2 TEST MODE)
Is water supplied?
Are replaceptacles correctly connected to the
terminals of inlet valve?
terminals of inlet valve?
Is detergent put in the correct compartment of
the drawer?
the drawer?
Is the detergent caked or hardened?
Open the tap.
Check the chamber (Air)
and the tube clogged
with impurity.
and the tube clogged
with impurity.
Clean the filter.
Replace the inlet valve.
Replace PWB assembly
(Main)
Refer to solution
^NO INLET_
Check the wiring on the
dispenser.
Put the detergent in the
correct position
PRE+MAIN
MAIN WASH
: Detergent
Clean the drawer.
NO WATER SUPPLY
DETERGENT DOES NOT FLOW IN
MAIN
WASH
SOFTENER
PRE -
WASH
21
YES
YES
YES
NO
NO
NO
NO
NO
YES
YES
YES
YES
Wiring diagram
HOT
ABNORMAL SOUND
SOFTENER DOES NOT FLOW IN
Fix the bolt tightly.
Replace the V-belt
(4400FR3116A)
(4400FR3116A)
Replace the motor.
Refer to
^NO WATER SUPPLY_
Check the wiring on the
dispenser.
dispenser.
Put it in the correct
compartment.
compartment.
Clean the cap and
drawer.
drawer.
Is the pulley bolt loosened?
Is the belt worn?
Is there friction noise from the motor?
Is water supplied?
Are receptacles correctly connected to the terminals
of inlet valve?
of inlet valve?
Is softener put in the correct compartment of
drawer?
Is the softner cap clogged?
22
Replace the sensor
(pressure)
Replace the PWB
assembly (Main)
Repair drain hose
Remove foreign material.
Reconnect or repair the
connector
connector
Replace the pump
assembly
assembly
Replace the PWB
assembly (Main)
When pressing [Spin] and [Temp.] at the same time after
draining, is the water level frequency 252 or more?
When pressing [Spin], [Temp.] buttons at the same time
while wash, is the water level frequency between
240?
draining, is the water level frequency 252 or more?
When pressing [Spin], [Temp.] buttons at the same time
while wash, is the water level frequency between
240?
Checking voltage between two pins as press the
power button is the voltage 240V~?
power button is the voltage 240V~?
Is the drain hose twisted or frozen?
Is the impeller of the drain pump clogged?
Is the connector disconnected, disassembled?
Is the coil of drain pump cut-off?
(resistance of coil is 90~160Ω)
When checking voltage between connectors
( , )on spinning, is the voltage 240V~
as the figure?
HEATING WITHOUT WATER
DRAIN MALFUNCTIONING
23
Replace the thermistor
(6322FR2046B)
(6322FR2046B)
Push the thermistor
tightly to the rubber.
When disconnect the connector (1) on the
PWB assembly (Main) is the resistance of the
Natural connectors
PWB assembly (Main) is the resistance of the
Natural connectors
~②( Blue/White),
③(Blue / White)₩between 2.5kΩ to 180kΩ
(105
(105
℃
~0
℃
)?
When checking thermistor on the tub,
is the thermistor loosened above 2mm from
the rubber?
HEATING CONTINUOUSLY ABOVE
THE SETTING WATER TEMPERATURE
Click on the first or last page to see other WD-1090FHB / WD-1098FHB service manuals if exist.