LG WD-1060FHD Service Manual ▷ View online
20
ERROR
SYMPTOM
CAUSE
8
9
• MAIN PWB ASSEMBLY is out of order
Replace the MAIN PWB ASSEMBLY
• Winding in the STATOR ASSEMBLY is short-circuited.
Replace the STATOR ASSEMBLY
• The connector (3-pin, male, white) in the LEAD WIRE ASSEMBLY
is not connected to the connector (3-pin, female, white) of
STATOR ASSEMBLY.
Reconnect or repair the connector
• The electric contact between the connectors 3-pin, male, white in
the LEAD WIRE ASSEMBLY and 4-pin, female, natural in the
MAIN PWB ASSEMBLY is bad or unstable.
Reconnect or repair the contact in the connector
• The LEAD WIRE ASSEMBLY between the STATOR ASSEMBLY
and MAIN PWB ASSEMBLY is cut (open circuited).
Repair the damaged (open-circuited) the LEAD WIRE
ASSEMBLY
• The hall sensor is out of order/defective.
Replace the STATOR ASSEMBLY
CURRENT
ERROR
LOCK
ERROR
SYMPTOM
GUIDE FOR SERVICE CALL
NO POWER
WATER INLET TROUBLE
21
8-1.DIAGNOSIS AND ANSWER FOR ABNORMAL OPERATION
8. ERROR DIAGNOSIS AND CHECK LIST
YES
YES
YES
NO
NO
YES
NO
NO
Is the power plug connected firmly to
220-240V~ outlet?
Power failure? or Breaker opened?
Is the outlet controlled by a switch
Visit to check
Is displayed?
Is the tap opened?
Is the tap frozen?
Is the water supply shut-off?
Is filter in the inlet valve clogged with foreign
material?
Visit to check
Clean the filter of
inlet valve
inlet valve
22
SYMPTOM
GUIDE FOR SERVICE CALL
DOOR OPEN ERROR
DRAIN TROUBLE
NO
YES
YES
NO
NO
YES
Did you press the Start/Pause button when
the door is open?
Visit to check
Check if the door switch is O.K
Is displayed?
Is the debris filter clogged with foreign
material such as pins, coins, etc?
material such as pins, coins, etc?
Is the drain hose frozen with water, kinked,
or crushed?
or crushed?
Visit to check
Close the door
Clean up
the filter.
the filter.
23
SYMPTOM
GUIDE FOR SERVICE CALL
Suds overflow from the
appliance.
(In this condition, wash and
spin do not operate
normally)
No effect of softener
YES
YES
YES
YES
YES
Is low-sudsing detergent for the drum
washing machine used?
Is the proper amount of detergent used
as recommended?
Recommend to reduce the amount
of detergent.
Is softener put in the correct compartment of
the drawer?
Is the drawer closed during wash?
Is the softener cap clogged?
Explain how to use softener
Clean the compartment for softener
Visit to check
LOW-SUDSING
DETERGENT
Compartment for softener
This appliance has the automatic suds sensing function which
operates under much suds condition for good rinse and
preventing overflow.
operates under much suds condition for good rinse and
preventing overflow.
When much suds are sensed, the suds removing function such
as drain, water input, and pause will operate without rotating the
drum.
as drain, water input, and pause will operate without rotating the
drum.
Click on the first or last page to see other WD-1060FHD service manuals if exist.