9. DISASSEMBLY INSTRUCTIONS
25
CONTROL PANEL ASSEMBLY
Unscrew 2 screws on the back of the top plate.
Pull the top plate backward and upward as shown.
Disconnect the ASSEMBLY connector.
Pull out the drawer and unscrew 2 screws.
Push 2 upper hooks down and pull the control panel.
Disconnect the PWB ASSEMBLY from the control panel by
unscrewing 7 screws.
unscrewing 7 screws.
* Be sure to unplug the machine out of the outlet before disassembling and repairing the parts.
26
DISPENSER ASSEMBLY
Disassemble the TOP PLATE ASSEMBLY.
Pull out the drawer slightly upward.
Unscrew 2 screws.
Disassemble hose clamps and hoses.
Disassemble the ventilation bellows and the water inlet
bellows from the tub.
bellows from the tub.
27
INLET VALVE ASSEMBLY
Disconnect the wiring connector.
Unscrew 2(4) screws from the back.
* When reconnecting the connector
* Cold only model
* Cold only model
Open the lower cover CAP by using coin and pull out the
lower cover inthe arrow direction after a screw is
lower cover inthe arrow direction after a screw is
unscrewed.
LOWER COVER
VALVE #1 (MAIN)
VALVE#2 (PRE)
Whited/Black-Black
Gray/White-Black
VALVE #1 (MAIN)
VALVE#2 (PRE)
VALVE#3 (HOT)
Whited/Black-Black
Gray/White-Black
Blue/Red-Black
28
DOOR ASSEMBLY
Open the door completely.
Remove the two screws from the hinge.
When removing the DOOR ASSEMBLY, it is necessary to
hold the BRACKET that is inner of the CABINET COVER.
hold the BRACKET that is inner of the CABINET COVER.
Take apart the CLAMP ASSEMBLY (cabinet).
Unscrew 2 screws from the CABINET COVER.
Open the lower cover cap and unscrew 1 screw inside
(Refer to page 27)
(Refer to page 27)
Take apart the LOWER COVER.
Disassemble the CONTROL PANEL ASSEMBLY.
(Refer to page 25)
(Refer to page 25)
Unscrew all the screws on the upper and lower sides of
the CABINET COVER.
the CABINET COVER.
Take apart the tub CLAMP ASSEMBLY
Make sure that the drain hole of the GASKET is put
beneath when reassembling the GASKET.
beneath when reassembling the GASKET.
Refer to the arrow mark on the TUB COVER.
GASKET