DOWNLOAD LG WD-10230N / WD-10230NU / WD-10230T / WD-10230TU / WD-10235T Service Manual ↓ Size: 2.31 MB | Pages: 34 in PDF or view online for FREE

Model
WD-10230N WD-10230NU WD-10230T WD-10230TU WD-10235T
Pages
34
Size
2.31 MB
Type
PDF
Document
Service Manual
Brand
Device
Washing Machine
File
wd-10230n-wd-10230nu-wd-10230t-wd-10230tu-wd-10235.pdf
Date

LG WD-10230N / WD-10230NU / WD-10230T / WD-10230TU / WD-10235T Service Manual ▷ View online

21
AC 220-240V
NO
NO
YES
YES
YES
NO
NO
NO
NO
YES
YES
NO
2
PWB ASSEMBLY (MAIN)
PWB ASSEMBLY (MAIN)
1
Time Delay
Bio
Bio
Replace the sensor 
(pressure)
Replace the PWB
assembly (Main)
Repair drain hose
Remove foreign
material.
Reconnect or repair the
connector
Replace the pump
assembly
Replace the PWB
assembly (Main) 
When pressing [Bio] and [Time Delay] at the
same time after draining, is  the water level
frequency 252 or more?  
When pressing  [Bio], [Time Delay] buttons at
the same time while wash, is the water level
frequency between 
220 - 240?
Checking voltage between two pins as press the
power button is the voltage  220 - 240V~?
Is the drain hose twisted or frozen?
Is the impeller of the drain pump clogged?
Is the connector disconnected, disassembled?
Is the coil of drain pump cut-off?
(resistance of coil is 90~160
)
When checking voltage between connectors
(
)on spinning, is the voltage 220 - 240V~ 
as the figure?
HEATING WITHOUT WATER
DRAIN MALFUNCTIONING
22
NO
YES
YES
WASH HEATER TROUBLE
When checking the voltage between 
connector the PWB assembly (Main)during 
cotton washing ,Is the voltage 
220 - 240V    ?
Replace the PWB 
assembly (Main)
YES
NO
After power off and the heater terminal is
disconnected, is the resistance 10 to 30   ?
Replace the heater 
assembly
NO
After power off,is the resistance of wire
(BROWN-BLUE) connectors between
10    to 30   ?
Normal
NO
YES
BROWN
BLUE
2
3
1
2
3
  ~    
220 - 240V~
(1)
PWB ASSEMBLY (MAIN)
Replace the thermistor
(6322FR2046F)
Push the thermistor
tightly to the rubber.
When disconnect the connector (1) on the 
PWB assembly (Main) is the resistance of the 
Natural connectors 
( Violet),
(Orange) between  2.5k
to 180k
(105
~0
)?
When checking thermistor on the tub, 
is the thermistor loosened above 2mm from 
the rubber?
HEATING CONTINUOUSLY ABOVE 
THE SETTING WATER TEMPERATURE
23
NO
YES
YES
YES
NO
NO
NO
YES
(1)
Time Delay
Bio
Bio
Pre W
Pre Wash
ash
Crease Care
Crease Care
3
B
1B
2
SPIN TROUBLE
Check the sensor
(Pressure) or hose 
(Sensor). 
If the problem is on the
sensor or the hose, replace
the sensor or the hose.
Normal
Correct the connector.
Replace the motor
assembly.
(Refer to the replacement
parts list)
Check on the spinning, is the frequency of the
water level 248 or more. The frequency can be 
checked by pressing the Bio and Time Delay buttons
at the same time on the program.
When pressing Pre WashCrease Care, and
POWER buttons at the same time after power off,
press the  START/PAUSE button 2 times, is the drum
low speed spin?
Is it disconnected, or disassembled?
Red:3pin ( )
Check the motor connector. Is the resistance of
the terminal same as the figure?
MOTOR TERMINAL
Resistance of terminal: 
About 6.5
Replace the PWB assembly (Main)
24
Be sure to unplug the machine out of the outlet before disassembling and repairing the parts. 
9. DISASSEMBLY INSTRUCTIONS
Unscrew 2 screws on the back of the top plate.
Pull the top plate backward and upward as shown.
Disconnect the PWB Assembly connector from Main
lead wire Assembly.
Pull out the drawer and unscrew 2 screws.
Push upper hooks down on the top and pull the control
panel.
Disconnect the PWB assembly (Main & Display) from
the control panel by unscrew 7 screws.
Hook
CONTROL PANEL
PLATE ASSEMBLY (TOP)
PANEL ASSEMBLY
(CONTROL)
PWB 
ASSEMBLY
(DISPLAY)
Page of 34
Display

Click on the first or last page to see other WD-10230N / WD-10230NU / WD-10230T / WD-10230TU / WD-10235T service manuals if exist.