DOWNLOAD LG WD-10225FD Service Manual ↓ Size: 3.42 MB | Pages: 36 in PDF or view online for FREE

Model
WD-10225FD
Pages
36
Size
3.42 MB
Type
PDF
Document
Service Manual
Brand
Device
Washing Machine
File
wd-10225fd.pdf
Date

LG WD-10225FD Service Manual ▷ View online

28
Disconnect the wiring connector.
Unscrew 2 screws from the back.
When reconnecting the connector
Cold only model
Cold and Hot model
Open the lower cover CAP by using coin and pull out
the lower cover in the arrow direction after a screw is
unscrewed.
1
2
3 Option
INLET VALVE ASSEMBLY
LOWER COVER
VALVE#1 (MAIN)
Whited/Black-Black
VALVE#2 (PRE)
Gray/ White - Black
VALVE #1 (MAIN)
Whited/Black-Black
VALVE #2 (PRE)
Gray/ White - Black
VALVE #3 (HOT)
Blue/Red - Black
29
Open the door completely.
Remove the two screws from the hinge.
When removing the DOOR ASSEMBLY, it is
necessary to hold the BRACKET that is inner of the
CABINET COVER.
Take apart the CLAMP ASSEMBLY (cabinet).
Unscrew 2 screws from the CABINET COVER.
Open the lower cover cap and unscrew 1 screw inside
Take apart the LOWER COVER.
Disassemble the CONTROL PANEL ASSEMBLY.
(Refer to page 26)
Unscrew all the screws on the upper and lower sides of
the CABINET COVER.
Take apart the tub CLAMP ASSEMBLY
Make sure that the drain hole of the GASKET is put
beneath when reassembling the GASKET.
Refer to the arrow mark on the TUB COVER.
GASKET
DOOR ASSEMBLY
30
Remove the BACK COVER.
Unscrew the bolt to pull out the ROTOR ASSEMBLY.
Disconnect the wiring connector.
Unscrew 6 bolts from the STATOR.
Remove the BODY FRAME.
(Only 1400 rpm models)
Note : Hook of connector (1) is on the backside
Pull out the HINGE, pressing its snap.
Do not use the pulled out HINGE again 
It may be taken off during operation.
Hinge
Damper
Rotor
Bolt
(1)
ROTOR ASSEMBLY, STATOR ASSEMBLY, FRICTION DAMPER ASSEMBLY
(ROTOR ASSEMBLY)
(STATOR ASSEMBLY)
(FRICTION DAMPER ASSEMBLY)
Clean the drain pump filter
3
2
3
2
2. Unplug the drain plug ( ),
allowing the water to flow out. At
this time use a vessel to prevent
water flowing on to the floor. When
water does not flow any more, turn
the pump filter ( ) open to the left.
3. Remove any foreign material
from the pump filter ( ). After
cleaning, turn the pump filter ( )
clockwise and insert the drain
plug ( 
)to the original place.
close the lower cover cap.
1
100
1. Open the lower cover
cap ( ) by using a
coin. Turn the drain
plug ( ) to pull out
the hose.
31
Remove PUMP and CIRCULATION HOSE.
Remove BELLOWS..
Disconnect the wiring.
Unscrew 2 screws 
Remove the DRAIN PUMP ASSEMBLY.
Loosen the M6 heater nuts to pull out the HEATER
ASSEMBLY.
When mounting the HEATER ASSEMBLY be sure to
insert the HEATER ASSEMBLY into the heater clip on
the bottom of the tub.
Pull it out by holding the THERMISTOR bracket.
If it is pulled by the wire, it may be broken.
When mounting the THERMISTOR again, make sure
that it is got back tight to the bushing.
DRAIN PUMP ASSEMBLY 
HEATER ASSEMBLY 
THERMISTOR 
CAUTION
Page of 36