(1)
SPIN TROUBLE
Check the S.PRESSURE SWITCH
ASSEMBLY or HOSE  (Pressure). 
If the problem is on the
S.PRESSURE SWITCH
ASSEMBLY or the HOSE,
replace the S.PRESSURE
SWITCH ASSEMBLY or the
HOSE.
Normal
Correct the connector.
Replace the STATOR
ASSEMBLY
(4417FA1994E)
Check on the spinning, is the frequency of the
water level 248 or more. The frequency can be 
checked by pressing the Rinse and Spin buttons at
the same time on the program.
When pressing Rinse, Spin and POWER buttons at
the same time after power off, press the  Start/Pause
button 2 times, is the drum spinning at low speed?
Is it disconnected, or disassembled?
[Red:3pin (1), NA:4pin (2)]
Check the motor connector, Is the resistance of
the terminal same as the figure?
MOTOR TERMINAL (1)
Resistance of terminal: 
About 5
10
Replace the MAIN PWB ASSEMBLY
25
Be sure to unplug the machine out of the outlet before disassembling and repairing the parts. 
9. DISASSEMBLY INSTRUCTIONS
Unscrew 2 screws on the back of the top plate.
Pull the top plate backward and upward as shown.
Disconnect the ASSEMBLY connector.
Pull out the drawer and unscrew 3 screws.
Push 2 upper hooks down and pull the control panel.
Disconnect the PWB ASSEMBLY from the control
panel by unscrewing 9 screws.
HOOK
PANEL ASSEMBLY (CONTROL)
PWB ASSEMBLY
(DISPLAY)
CONTROL PANEL ASSEMBLY
TOP PLATE ASSEMBLY
26
Disassemble the TOP PLATE ASSEMBLY.
Pull out the drawer slightly upward.
Unscrew 3 screws.
Disassemble hose clamps and hoses.
Disassemble the ventilation bellows and the water inlet
bellows from the tub.
Option
DISPENSER ASSEMBLY  
DISPENSER ASSEMBLY
DRAWER
27
Disconnect the wiring connector.
Unscrew 2 screws from the back.
When reconnecting the connector
Cold only model
Cold and Hot model
Remove the back cover.
Unscrew 2 screws.
Pull the MAIN PWB ASSEMBLY as shown.
Open the lower cover CAP by using coin and pull out
the lower cover in the arrow direction after a screw is
unscrewed.
1
2
3 Option
INLET VA LVE ASSEMBLY
MAIN PWB ASSEMBLY
LOWER COVER
VALVE#1 (MAIN)
Whited/Black-Black
VALVE#2 (PRE)
Gray/ White - Black
VALVE #1 (MAIN)
Whited/Black-Black
VALVE #2 (PRE)
Gray/ White - Black
VALVE #3 (HOT)
Blue/Red - Black
Page of 35