Tub Cycle 
Fixed nut
 
Tub Cycle 
Outer tub 
Inner tub
Cutch
 
Pivot
 
 
Connector   drain hose 
9-3 Back panel Disassembly 
 Unplug fixed screw on back panel and then 
remove back panel. 
 
9-4.Update boom components 
② 
  Separate top cap from the washer. 
 
As is shown, separate boom from outer tub. 
③ 
 Do not remove the boom components and 
replace it whole. 
④ 
 Assemble according to Table below(position 
and colour) 
 
 
 
 
Position P/NO. 
PIVOT(Color 
)
K100 Blue 
 
 
 
Fixed nut
 
Rotor
 
Stator
Rotor nut
 21
 
 
 
9-5. Replace rotor and stator 
② 
  remove rotor nuts with wrench(M18)。 
 
 
remove and fetch out rotor as is shown. 
                 
Fixed hole 
 
③ 
Remove fixed hole and Hydraulic 
conductivity board。 
 
retaining piece
 
                        Stator base 
Hall element   
 
④ 
  Unplug hall element and stator connector 
before removing stator. 
 
 22
 
 
Circlip  
 
⑤ 
  Untighten six stator fixed screws 
⑥ 
 Check the direction of inner calandria 
circlip. 
 
⑦ 
 Tighten stator with handles and remove 
the last screw. 
 
Hallelement  
Rtaining piece    stator base 
⑧ 
  Pay attention to the wire statue in case of 
noise. 
 
 
 
9-6.Replace Clutch Components 
 
Remove 9 fixed screws on clutch and fetch 
out. 
 
 23
 
 
10. Test running 
Applied model: T8504DE 
Water test mode
 
● 
Use test program and press “DELAY”,”RINSE”and “POWER” together under no load and 
water level around 28L . 
● 
All the indicators are on under “TEST” mode. Press “START/PAUSE” to test following items.   
Number 
Test method 
LED display 
Test items 
1 Initial 
status 
Alternation display of Version U: 00 
and water level frequency 
Water level sensor abnormal 
display“PE“ 
All the indicators are 
on。 
Water level frequency 
is 218-250。 
Press one time 
Display “1“ 
Test Alpha stream 
Press twice 
Display “2“ 
Alpha stream stops 
Press three times 
Display hardness value 
Hardness value is 
0-255 
Press four times 
Display “4“ 
Drain 
Press five times 
Automatic switch is off 
All indicators are off
 
Anhydrous test mode 
● 
Use test program and press “DELAY”,”RINSE”and “POWER” together under no load and no 
water. 
 
● 
Test following items under TEST mode. 
Number 
Test method 
LED display 
Test items 
Initial status 
Display “TS” 
 
Press “WASH” and then press 
“START/PAUSE” 
Display “20” 
Check if it is under normal 
“WASH” condition 
Press “POWER/AUTO OFF” 
Automatic switch is off
All the indicators are off 
Press combination button again
Display “TS” 
 
Press “SPIN”    and then press 
“START/PAUSE”  
Display “10” 
Check if it is under normal 
“SPIN” condition. 
 