DOWNLOAD LG T8018AEEP5 Service Manual ↓ Size: 8.44 MB | Pages: 37 in PDF or view online for FREE

Model
T8018AEEP5
Pages
37
Size
8.44 MB
Type
PDF
Document
Service Manual
Brand
Device
Washing Machine
File
t8018aeep5.pdf
Date

LG T8018AEEP5 Service Manual ▷ View online

 
3-5. Safety Reed Switch 
 
 
 
● 
This reed switch system may differ from the old one. The reed switch is in PC board module 
and works through contacting with magnets inside lid switch. It would not work until lid is 
closed and current is passed through.\ 
●  Do not place any magnetic object on the machine, which may lead to operation error. 
 
3-6. Intelligence perception 
●  Seven intelligence perception including unbalance, measurement, water level, door openness, 
water temperature , water hardness and detergent density 
●  Unbalance  perception  may  differ  from  that  of  old  models.  It  percepts  unbalance  through 
motor rotate speed of DD motor sensor under “SPIN” and abnormal operation.   
 
3-7.10 Section level   
● 10 section water level 
 
●  The  water  level  can  be  adjusted  manually  with  a  cycle  of 
[7→8→9→10→1→2→3→4→5→6→7…]  according  to  requirements  as 
the button is pressed. 
Water 
level/detergent 
 
 
Water level 
 
9
 
 
 
4. Identification of Parts 
 
0
1
 
 
 
5-2. Connecting Water Supply Hose 
●  Connecting Water Supply Hose to the machine 
 
 
 
Check to see if there is a black rubber seal inside the 
connector. If not, it would cause water-leakage.   
 
Hose 
Rubber seal
 
Inlet valve 
Connect  the  water  supply  hose  to  inlet  valve  of  the 
washing machine vertically.   
 
Connect  the  water  supply  hose  to  inlet  valve  of  the 
washing machine, and then lock it by turning the hose 
connecting part. 
 
 
●Connecting Water Supply Hose to water tap 
 
Separate  connector  from  the  Water  Supply  Hose  by 
pulling the Pressing Rod and the Pressing Handle that 
is attached to the Water Supply Hose.   
● 
If  the  tap  diameter  is  too  large  ,  remove  the  guide  plate 
inside。
 
 
 
 
Connector 
Press
Press 
  Water 
Untighten  the  4  screws  on  the  upper  connector  and 
turning  the  down  connector  to  leave  space  about  3 
screws between the two connectors.   
If  the  tap  diameter  is  too  large, 
remove the guide plate inside. 
Upper-con
Guide 
3 screws
Down-con
 
1
1
 
 
 
 
Adjust four screws on connectors to make sure that the 
two screws near the wall are in tight contact with 
outside of water tap.   
 
The screws close to the wall should 
be screwed beforehand. 
Water tap 
 
Push the upper connector up till the rubber packing 
can adhere completely to the tap (Attention: Do not 
remove the rubber packing). 
 
 
Turning two screws to be in tight contact with water 
tap. Then tighten the 2 screws. 
 
 
 
Turn the lower connector to be in tight contact with 
the upper one (Loose connection will cause the water 
leakage). Make sure the clearance between the two 
connectors is less than 3mm. 
 
 
 
Confirmation 
<3mm 
Connector 
module 
 12
Page of 37
Display

Click on the first or last page to see other T8018AEEP5 service manuals if exist.