3. Specifications
Model
T7018AEC6&& T7018AECA T7018AEC
Power supply
220V~, 50HZ
Input power
WASH POWER 430W, SPIN POWER 240W
Capacity
Size (mm)
540×540×935
(L×W×H)
Water level
10 LEVEL
Water usage
148L(high water level, RINSE for 2 times )
Water tab pressure
0.2kgf/cm²~8kgf/cm²
Washing model
washing , intelligence sense
Control model
FUZZY logic control
SPIN speed
690-720RPM
Program
FUZZY(NORMAL),
,
QUICK
WASH,
,
E XTRA
CLEANING
SILENT,
FAVORITE,
TUB
CLEAN
Filter
2
Softener
Automatic
PC board displays
Yes
Accessories
Water supply hose(1)
Drain hose(1)
Rat-proof base(1)
Bolt(1)
5
WOOL
J EANS
X
T7018AEC6&&(7kg) T7018AECA(7kg) T7018AEC(6kg)
SMART CLEANING(7kg)
(6kg)
3. Feature and technique instruction
3-1. DD Centrifugal Washing
WASH PROCESS
WASH PRINCIPLE
Soils
Centrifugal flow cross
Tub rotates
Drive tub to rotate directly through
DD motor. Stream crosses through
laundry and injects from the top of
tub.
DD motor. Stream crosses through
laundry and injects from the top of
tub.
Laun
STR
The stream takes away stains on the laundry
3-2.
DD Inverter DC Motor
■
DD Inverter DC Motor sets magnet on rotor and winds coils on stator, whose current is
controlled by sensor and control chips instead of traditional brush.
6
through laundry
■
Structure of DD Inverter DC Motor
`
Rotor
Motor
Sensor module
Coil
Stator
Magnet
■
Working Principle
Motor speed is controlled by the signal width of pulse.
Oscillogram
(Low rotate speed )
Narrow pulse width
(Low rotate speed)
Oscillogram
(High- rotate
speed )
Broad pulse width
(High- rotate speed )
7
3-3. Controler
the controler of WF-HD850FS as below
* 3-4. Structure and working principle of drain valve
■
Start draining:
starting with turning motor rotor and pulling the drain valve to
(as seen below)
Stop draining: End with turning rotor to initial point to close the valve and stop draining.
Drain motor
Drain valve rod
Rotor
Drain valve inlet
Bellows
<Structure of drain motor>
<circuit of drain motor>
* For non pump model
■ Features
●
Drain motor rotor can only be rotated counterclockwise when power is on.
●
For easy maintenance, Drain motor rotor can only be rotated counterclockwise when power is
on.
●
●
The function of inside button in motor is to sensor the initial position。 The “POWER OFF”is
at the position of stopping draining.
●
●
Rotor shall finally return to original position and stop draining when pressing “START/PAUSE”
or “POWER” button. But it does not work while unplugging the power or power failure and
restart when power is on.
restart when power is on.
●
During maintenance, turn counterclockwise
to implement forced drainage.