4-7. TROUBLESHOOTING WITH ERROR CODE
41
Display
Problem Diagnosis 
Standard
Estimated Cause of 
Abnormal Condition
Action
Water supply problem
(When water is not 
supplied) 
•  When it did not reach the 
RESET level frequency 
(26.0kHz) in 12 minutes 
after starting the water 
supply 
•  If the level frequency is 
less than 26.0kHz, and if 
the level frequency is not 
changed for 10 minutes
1.   When the faucet is locked or 
frozen 
2.   When the tap water supply is 
stopped 
3.   When the filter at the top of the 
water supply valve is blocked 
with foreign object
4.   When the connector connected 
to the water supply valve is 
disconnected or contact is 
defect
5.   When the natural colored 4 pin 
connector connected to 
controller is fallen off or contact 
is defect
6.   Problem in the load drive part in 
the controller
7.   Problem with pressure switch 
pressure detection
•  Open the faucet for water 
supply
•  Wash when the water 
supply condition is met 
•  Clean or replace the filter
•  Reconnect the connector 
or correct the contact 
defect
•  Reconnect the connector 
or correct the contact 
defect 
•  Replace controller  
•  Check pressure switch 
Discharge problem 
 
(When it is not 
discharged)
•  When it did not reach the 
RESET level frequency 
discharge (26.0kHz) in 12 
minutes after starting the 
discharge
1.   When the discharge hose is not 
lowered
2.   When the discharge hose is 
bent or clogged (Clogged by 
freezing or by foreign object) 
3.   When the connector connected 
to the discharge pump/drain 
valve or the blue 3PIN connector 
connected to the controller is 
fallen off or contact is defect
4.   When the discharge pump/
drain valve unit is defect. (When 
a separate 220V/110V power is 
directly connected to the 3PIN 
connector of the discharge 
motor, it still does not work) 
5.   When there is a problem in the 
controller assy
•  Put down the discharge 
hose 
•  Remove the cause of the 
clogging of the discharge 
hose
•  Reconnect the connector 
or correct the contact 
defect connector 
•  Replace discharge motor
•  Replace controller
Dehydration problem
(When dehydration is 
not working) 
•  Unbalance of the laundry 
during the dehydration
1.  When the laundry is not evenly 
placed in the (INNER TUB ASM) 
and skewed to one side
2.  When the washer is installed on 
a slope
•  Distribute the laundry 
evenly in the washer but 
(horizontal) 
•  Adjust the leg heights for 
the washer to be leveled. 
42
Display
Problem Diagnosis 
Standard
Estimated Cause of 
Abnormal Condition
Action
Lid open 
(When the lid cannot 
be locked) 
•  When the door cannot be 
locked
•  When the door cannot be 
open
1.   When there is a foreign object 
in the lid lock hole
2.  when lid lock unit is defect
3.   When the connector connected 
to the lid lock is fallen off or 
contact is defect
4.  When the hook is defect 
5.  When the lid is defect 
6.  When the controller is defect
•  Remove the foreign object 
in the lid lock hole 
•  Replace the lid lock 
•   Reconnect the connector 
or correct the contact 
defect
•  Replace the lid
•  Replace the lid
•  Replace the controller
Lid locked  
 
(When the lid cannot 
be locked) 
•  When the door cannot be 
locked
•  When the door cannot be 
open
1. When there is a foreign object in 
the lid lock hole
2.  When lid lock unit is defect
3.   When the connector connected 
to the lid lock is fallen off or 
contact is defect
4.  When the hook is defect 
5.  When the lid is defect 
6.  When the controller is defect
•  Remove the foreign object 
in the lid lock hole 
•  Replace the lid lock 
•  Reconnect the connector 
or correct the contact 
defect
•  Replace the lid
•  Replace the lid
•  Replace the controller
Level sensor problem 
 
(When there is a 
problem with the level 
sensor) 
•  When the frequency 
generated by recognizing 
level height in the pressure 
switch goes out of the 
standard boundary (It occurs 
when the condition of the 
level frequency less than 
20.0KHz or over 30.0KHz is 
maintained for 5 sec. or more)
1.  When the connector connected 
to the pressure switch or the 
blue 6 pin connector is fallen off 
or contact is defect
2.   When the pressure switch unit 
is defect
3.  When the controller id defect
•  Reconnect the connector 
or correct the contact 
defect
•  Replace pressures witch
•  Replace controller
• 
Motor locking problem
(When there is a 
problem with the motor)
•  When there is a problem 
with the hole sensor 
detecting the rotation of 
the motor
•  It occurs when the motor is 
locked
1.   When the connector connected 
to hole sensor or blue 4 pin 
connector is fallen off or contact 
is defect
2.   When the hole sensor unit is 
defect
3.   When the controller is defect
4.   When the motor connection 
connector is fallen off or contact 
is defect
5.  When the bearing is locked
6.  Hole sensor location defect
•  Reconnect the connector or 
correct the contact defect
•  Replace hole sensor 
•  Replace controller 
•  Reconnect the connector or 
correct the contact defect
•  Turn the inner tub with hand 
to check the status, and if it 
cannot be rotated, replace the 
bearing housing assy. 
•  Replace hole sensor
Clutch problem
(When there is a 
problem in the clutch) 
•  When the clutch is not 
working
1.  Connection part contact defect 
2.  Coupling damaged
3.  Pulsator locked
•  Check the connection part 
reconnection defect and 
correct
•  Disassembly the Motor and 
check the damage of the 
coupling (If it is damaged, 
replace the part) 
•  Check the pulsator locking by 
foreign object (Remove the 
foreign object) 
43
Display
Problem Diagnosis 
Standard
Estimated Cause of 
Abnormal Condition
Action
Coin stuck 
(When there is a 
problem with the motor 
due to foreign object)
•  Occurs when motor is 
locked
1.   When foreign object such as 
coin, pin, or clip entered the 
washing plate
•  Remove the coin or foreign 
object stuck between the 
washer vane with pliers, 
etc.
THERMISTOR
•  Thermistor has a bad 
connection or failed
•    Check the connections at the 
Thermistor and at the WHITE 
3-pin connector at the main 
board 
•  Test thermistor to determine it is 
not detective
•  Reseat the connector. 
 
 
 
•  Replace the thermistor if 
necessary.
Power
Failure
ERROR
•  The washer experienced a 
power failure
•    When occurred a power failure. 
•    When the power cord is fallen 
off suddenly.
•  Restart the cycle.
•  Reconnect the power cord.
Drain Valve Problem
•  When drain valve is not 
working
•    Connection part contact defect
•  Check the connection part 
reconnection defect and 
correct.
•  Replace the new drain 
valve.
OVER
FLOW
ERROR
•  When water is overflowed •    Check the valves to be sure 
there is no input leakage. Then 
check the drain hose and make 
sure the drain pipe is between 
0.9 ~ 1.2 m (36 and 48 inches) 
above the floor.
•  Check for blockages and leaks 
in the air hose between the tub 
and the pressure switch.
•  Check and repair any air 
leakages at the air hose 
connector on the outer tub and 
at any connecting parts.
•  Install the drain hose 
between 0.9 ~ 1.2 m (36 
and 48 inches) above the 
floor.
•  Replace pressure sensor 
switch
•  Remove the foreign 
objects in pressure sensor 
switch air hose.
44
DRAIN ERROR
Yes
Is OE displayed?
Reconnect or 
repair the 
connector
No
Is the connector connected to 
pump motor  assembly 
disconnected or 
disassembled? 
When you enter the SVC 
Mode, is the water level 
frequency below 26.0 kHz?
Drain pump
Connection connector
Yes
No
Is the coil of the drain pump 
too high or low? (resistance of 
the coil is 10-20 Ω)
Yes
Check the AIR 
CHAMBER, the 
tube (clogged), 
and press 
switch
Yes
Is the voltage between 
connectors out of range? 
(WH6 Pin 1)
- After remove Terminal  
Position Assurance
of connector, check as follows. 
 Pump running : (230V ± 5%)
 Stopped Motor/Pump : 0~1V
 Method
 1. Enter the SVC Mode.
 2.Press Start/Pause button
  : 1 time  Main Version   
  : 2 times Display Version
  : 3 times  Inlet valve check mode
  : 4 times  Cold Valve, Bleach Valve
  : 5 times  Rinse Valve, Hot Valve
  : 6 times  Jet Spray Valve
  : 7 times  Heater Check
  : 8 times  Alpha Check
  : 9 times  Pump Check  
[Note] Environmental check list  
1) The drainage hose must not stay in a lower position
2)  The drainage hose must not be bent or clogged in any 
way due to the surrounding physical configuration
3) The drainage hose must not get frozen at all times.
4)  The drainage pump must not have any improper  
substance or material inside that may cause a 
machine breakdown.
Yes
No
Replace the 
DRAIN PUMP 
ASSEMBLY.
Replace the 
MAIN PCB
ASSEMBLY.
Page of 66
Display