LG LSWF388HVS Service Manual ▷ View online

46
9-4. PUMP MOTOR ASSEMBLY
Wiring
diagram
Circuit in the MAIN PWB
Wiring Diagram
MICOM
IC
R
5V
Rg
Cg
Vdc
Rs
Cs
PCB
CONNECTOR
PUMP
Vac
2
1
4
3
Pump Driving circuit
MAIN PWB
NA2
1 2 3
1
2
3
3 2 1
3 2 1
1
2
3
4
1 2 3 4
BL3
SB
SB
SB
BK
BN
BN
DRAIN
PUMP
CIRCULATION
PUMP
BK
Object
Function
Test
points
Result
* Each circuits of loads in wiring diagram are all same.
Two pump motors are used to drain the tub and to circulate the water / detergent solution.
Drain Pump
Drain Pump
Circulation Pump
Circulation Pump
Test Points
Result
(1) to (2)
10-20 
Test Points
Result
(1) to (2)
18-30 
T.P
For Drain
For Circulation
(1)(2)
(2)
(1)
(1)
(2)
47
9-5. INLET VALVE ASSEMBLY
Wiring
diagram
Circuit in the MAIN PWB
INLET
VALVE
Vac
Rs
Vdc
Cg
Rg
IC
MICOM
Cs
PCB
CONNECTOR
Inlet valve driving circuit
Function
Test
points 
and 
Result
Depending on the cycle and water temperature, the controller will energize the hot or cold
water valve solenoids to meet the selected water temperature.
After pull out the connector of defective valve, check the resistance.
Test points
(1)-(2)
Result
0.8-1.2 k
Wiring Diagram
MAIN
WASH
AG
VALVE
PRE
WASH
BLEACH
HOT
VALVE
1
2
1
2
1
2
1
2
1
2
RD
BL
BL
RD
NA
WH
NA4
VT
GY YL
BL
NA2
BL3
4
3
2
1
1
2
3
1
2
3
4
3
2
1
4
3
2
1
4
3
2
1
COMMON
(BK)
MIAN PWB
INLET VALVE
* Each circuits of loads in wiring diagram are all same.
(1)
(1)
(2)
(1)
(2)
(2)
(1)
(2)
(1)
(2)
(1)
(1)
(2)
(1)
(2)
(2)
(1)
(2)
(1)
(2)
48
9-6. HEATER ASSEMBLY
Wiring
diagram
Circuit in the MAIN PWB
MICOM
12V
Heater
Vac
X100
43
43
Tab Relay
Heater driving circuit
Wiring diagram
MAIN PWB
(X71)
3 4
3 4
3 4
3 4
3 4
3 4
(X135)
(X134)
BK
BL
YL
RD
GY
BL
BK
BK
Vac
WASH
HEATER
STEAM
GENERATOR
HEATER
YL
FUSE
FUSE
Function
Test points
Result
1. The wash heater is designed to raise the wash water to the desired temperature
selection during certain wash cycles.
2. The steam generator heater is designed to make the water to the steam during
steam cycles. 
Wash Heater
Steam Generator Heater
* Each circuits of loads in wiring diagram are all same.
Wash Heater
Steam Generator Heater
Test Points
Result
(1) to (2)
12-18 
Test Points
Result
(1) to (2)
12-18 
(1)
(2)
(2)
(1)
49
9-7. THERMISTOR ASSEMBLY
Wiring
diagram
Circuit in the MAIN PWB / Wiring Diagram
MAIN PWB
MICOM
NA3
BL
BN
WH
1
2
1
2
1
2
1
2
WH
WASH
THERMISTOR
STEAM
GENERATOR
THERMISTOR
1
2
3
4
5
6
1
5V
5V
R
R
R
R
C
C
C
C
2
3
4
5
6
Function
Test
points
The thermistor (temperature sensor) is used to monitor water temperature in the tub
or steam generator.
Wash Thermistor
(2)
(1)
Steam Generator Thermistor
(1) (2)
(1) (2)
Page of 67