Open the door completely.
Remove the two screws from the hinge.
When removing the DOOR ASSEMBLY, it is
necessary to hold the BRACKET that is inner of the
CABINET COVER.
Take apart the CLAMP ASSEMBLY (cabinet).
Unscrew 2 screws from the CABINET COVER.
Open the lower cover cap and unscrew 1 screw inside
Take apart the LOWER COVER.
Unscrew all the screws on the upper and lower sides of
the CABINET COVER.
Take apart the tub CLAMP ASSEMBLY
Make sure that the drain hole of the GASKET is put
beneath when reassembling the GASKET.
Refer to the arrow mark on the TUB COVER.
GASKET
DOOR ASSEMBLY
29
Remove the BACK COVER.
Unscrew the bolt to pull out the ROTOR ASSEMBLY.
Disconnect the wiring connector.
Unscrew 6 bolts from the STATOR.
Remove the BODY FRAME.
Note : Hook of connector (1) is on the backside
Pull out the HINGE, pressing its snap.
Do not use the pulled out HINGE again
Do not use the pulled out HINGE again
It may be taken off during operation.
HINGE
Damper
Rotor
Bolt
(1)
ROTOR ASSEMBLY, STATOR ASSEMBLY, FRICTION DAMPER ASSEMBLY
(ROTOR ASSEMBLY)
(STATOR ASSEMBLY)
(FRICTION DAMPER ASSEMBLY)
Open the lower cover cap (
)
by using coin.
Unplug the drain plug (
) , then
the water flows out,
At this time use a vessel
to prevent water flowing on the
floor. If the water does not flow any
more,turn the pump filter (
At this time use a vessel
to prevent water flowing on the
floor. If the water does not flow any
more,turn the pump filter (
)
open to the left.
Take out any foreign material
from the pump filter (
from the pump filter (
). After
cleaning, turn the pump filter (
)
clockwise and insert the
drain plug (
drain plug (
) to the original
place. close the lower cover cap.
Clean the drain pump filter
1
100
3
2
3
2
30
CAP
(Remaining Hose)
Screw
PUMP HOSE
BELLOWS
Remove PUMP HOSE.
Remove BELLOWS..
Remove CAP (Remaining Hose.)
Disconnect the wiring.
Unscrew 2 screws
Remove the DRAIN PUMP ASSEMBLY.
Loosen the M6 heater nuts to pull out the HEATER
ASSEMBLY.
When mounting the HEATER ASSEMBLY be sure to
insert the HEATER ASSEMBLY into the heater clip on
the bottom of the tub.
Pull it out by holding the THERMISTOR bracket.
If it is pulled by the wire, it may be broken.
When mounting the THERMISTOR again, make sure
that it is got back tight to the bushing.
DRAIN PUMP ASSEMBLY
HEATER ASSEMBLY
THERMISTOR
CAUTION
31
SWITCH ASSEMBLY, DOOR LOCK
WHEN FOREIGN MATERIAL IS STUCK BETWEEN DRUM AND TUB
Take apart the CLAMP ASSEMBLY (cabinet) and
release the GASKET.
Unscrew 2 screws holding the DOOR SWITCH
ASSEMBLY.
Disconnect the door lock from the wiring connector.
Remove the HEATER ASSEMBLY.
Remove the foreign material (wire, coin and others) by
inserting a long bar through the hole.