DOWNLOAD LG F84A8YD / F14A8YD25 / F84A8YD6 Service Manual ↓ Size: 13.58 MB | Pages: 62 in PDF or view online for FREE

Model
F84A8YD F14A8YD25 F84A8YD6
Pages
62
Size
13.58 MB
Type
PDF
Document
Service Manual
Brand
Device
Washing Machine
File
f84a8yd-f14a8yd25-f84a8yd6.pdf
Date

LG F84A8YD / F14A8YD25 / F84A8YD6 Service Manual ▷ View online

42
NO
2. Water Leak from Dispenser
Are the gasket (seal) 
and door cleaned regularly?
Is the door or gasket damaged?
Are the inlet hoses loose or cracked/split?
Replace the damaged parts.
Replace the 
Inlet Hoses
.
Clean the periphery of 
Gasket
and 
Door 
regularly.
3. Unknown – Water on Floor 
YES
Is the washer horizontal ?
Adjust the height of washing machine to be kept
horizontally. (Page 8)
NO
Are the drain filter and manual
drain hose open?
YES
NO
Check!!
Turn the filter cap clockwise to close.
YES
YES
NO
43
      
    !"  # $#% & '( # '(  $#)( #**%
+ +# ,#-" +(" '**-.
         
 #
'-
/  # 0 1
/ 1 # 0 
2 9
2 9
1
1
0
/
9. PART INSPECTION
44
9-2. DOOR LOCK SWITCH ASSEMBLY
         
  
 
 
 
 
!! "#
$%&
'
(%
%
)
AC
Common
terminal
of Valve
* !
1. Operation for door closing
- After the system turns on, PTC heating starts up through terminal 2-4's
authorizing the power on.
- After PTC heating starts up and before solenoid operation is driven, force
the system to the off position through CAM (or Slider return spring)
⇒ Door close
- Authorizing one impulse through terminal 3~4 (PTC & solenoid) will make
the door lock.
- Door lock is detected when switches in terminal 4~5 are set closed.
⇒ CAM rotation (or Positioning slider return spring) will forcibly clear off
the connection. The maximum, allowable number of impulse authorization is 2.
⇒ Upon the third authorization of the impulse, the position of CAM
(or Slider return spring) goes back to the door-open position.
- Authorizing the impulse occurs in 5 seconds upon input for max
performance and two authorization processes are allowed at most
⇒ Normal operation period of PTC heating : 1-5 seconds.
2. Operation for door opening
- With a temporary stop, door automatically opens by CAM rotations
(or positioning slider return spring) after authorizing the impulse from the
terminal 3~4 and power turns off – maximum of 3 times of the authorizing period.
- Upon the fourth authorization of the impulse, the position of CAM (or Slider
return spring) goes back to the door-close position.
The Door Lock Switch Assembly consists of Heating PTC, a Bimetal,
a Protection PTC, and a Solenoid. It locks the door during a wash cycle.
45
Test
points
Result
!
"
#
!
"
#
Page of 62
Display