LG F8069QDP Service Manual ▷ View online

6
3. PARTS IDENTIFICATION
Drawer
Door
Adjustable Feet 
Power Plug 
Control Panel
Drain Pump Filter
Drain Plug
Lower cover cap
If the supply cord is
damaged, it must be
replaced by the
manufacturer or its
service agents or a
similarly qualified
person in order to
avoid a hazard.
ACCESSORIES 
Inlet hose(1EA)         Option : Hot / Cold(2EA)
Spanner
Drum 
Lower cover 
(For datergent and
fabric softener)
7
4. INSTALLATION
INSTALLATION
The appliance should be installed as follows.
Check the conditions of installation area.
1. Check level ground.
On raised foundations or upper level homes, the 
vibrations
can be caused by the type of flooring. 
It may be 
necessary to move
the 
machine
to a different area in the home or have the floor
reinforced to properly support the operation of the unit.
2. Check humidity or any foreign objects under the feet.
Clean the floor, and there should not be any foreign objects under the feet.
If the unit has foreign objects underneath the feet, this will prevent the unit from being leveled properly 
and will cause 
vibrations
and 
slipping
.
Remove any foreign objects
, if any from underneath the machine and level unit properly.
See below for examples of foreign objects.
1
Open the box and check appliance condition.
2
horizontal
Capet
Paper
Laminated
paper
Washer
Base Packing
Wrench
This leveling (or spanner) wrench must
be used to remove the shipping bolts
and level the unit. This should be kept
for future use.
Packing Support
Purchased
stopper
8
Use spanner to remove transit bolts.
3
Confirm the distance between the appliance and the wall.
4
The tap connection and hose connection must be parallel.
5
Without removal of transit bolts
Spin noise
and 
shaking
.
X 4 EA
Transit bolts
More than 2cm
If the distance is less than 2cm,
the water supply hose will 
kink
or 
fold
1. Normal Tap without thread & 
screw
type inlet hose.
1.
Unscrew the fixing screw to
attach the tap.
2.
Push the connector up till the
rubber packing is in tight contact
with the tap. Then tighten the 4
screws.
3.
Push the water supply hose
vertically upwards so that the
rubber packing within in the hose
can adhere completely to the tap
and then tighten it by screwing it
to the right.
1.
Untighten the upper connector
screw.
2.
Push the upper connector up
till the rubber packing is in 
tight contact with the tap. Then
tighten the 4 screws.
3.
Connect the water supply hose
to the middle connector, pushing
the plate down.
• In case the diameter of the tap
is large remove the guide plate.
• Turn the middle connector not to
have water leaked. 
• Make sure that the rubber seal is
inside the hose connector. 
• To separate the water supply
hose from the middle connector
shut off the tap. 
Then pull the inlet hose down,
pushing the plate down.
• Make sure that there are no
kinks in the hose and that it is
not crushed.
2. Normal Tap without thread & 
one touch
type inlet hose (Single inlet models)
Upper 
Connector
Fixing screw
Guide plate
Connector
Rubber packing
Upper
Connector
Rubber packing
Upper
Connector
Plate
Water supply
hose
Rubber seal
Hose connector
Upper
Connector
Middle 
connector
Rubber
packing
Upper 
Connector
Fixing screw
Middle 
connector
Rubber
packing
Upper
Connector
Plate
Water supply
hose
9
Connect Drain Hose.
6
Connect power plug.
7
If the drain hose is not installed properly, the unit will not drain properly.
This allows water to back flow into the unit which can cause odors.
Refer to Owner Manual for proper drain hose installation.
The odor could also be coming from the home’s drain to which the drain hose is attached.
In this type of drain hose installation, the odor could be coming from the standpipe.
This odor can come up the drain hose and into the unit.
Pour a cup or two of bleach or vinegar down the home drain 
and let it sit for 24 hours before running another cycle.
This will help eliminate odor from the home drain. 
If a cycle is started too soon after doing this, it will not help the issue.
Connect the power plug to the wall outlet.
Avoid connecting several electric devices, 
it may be the cause of a fire.
Laundry tub
Max. 100cm
Max. 100cm
Retainer
Tie
strap
Hose
Page of 44
Display