24
Water Outlet Error (OE)
Is the drain hose kinked ?
Check drain hose for kink and straighten the 
Hose
.
Drain Hose
Is the 
Pump filter
clogged ?
Next Page
Check & Clean 
Pump Filter
.
YES
YES
NO
NO
This kind of accumulation on the drain filter not only
prevents proper drainage, but also will promote
bacteria growth and cause odors.
This drain filter should be cleaned once a month.
* How to disassemble and clean pump filter
Open the Cover by coin or
finger(only new model)
Cover
Drain water by removing the
hose cap.
Disassemble the pump
filter by turning the filter
cap counterclockwise.
Filter clogged by foreign objects
Assemble & close cap
Pump Filter
filter Cap
Hose Cap
Clean the filter
Filter Cap
25
Is the 
Connector
connected correctly to
the 
Main PCB
and the 
Pump Motor 
?
Or is the 
Harness
alright ?
Is the 
Standpipe Height
greater
than 1.0 m above the floor?
When there is no water in the
pump casing, is the water level
frequency over 26.0khz ?
Observe 
Standpipe Height
requirements 
of 
1.0
maximum.
- Your washer will not be able to drain out 
water adequately, if the standpipe exceeds 1.0 m.
In this case, water may flow back into the washer.
Check the 
Air Chamber
and the 
Tube
(clogged).
Check the water level frequency again, if it is over
25.5KHz, replace the 
If it is clogged, Pressure
switch.
YES
NO
Reconnect or repair the 
Connector
.
Or replace the 
Harness
.
NO
Replace the 
Main PCB
.
NO
Replace the 
Pump Motor
.
Is the resistance of the Pump Motor out
of range 152~175Ω?
Or is the Impeller operating normally?
Does the Pump motor start, when the spin mode
starts?
Clean the drain hose.
If the drain hose blocked?
Escape
Binding
NO
NO
YES
YES
YES
OR
YES
YES
26
Over Flow Error (FE)
Is the water coming in
drawer ?
Replace the
 
.
After power off for 10 sec. and power on.
Does the water level over reference line   Is
the water level frequency 26.2Khz ?
Or does
the water level over reference line   is the water level frequency 26.2Khz ?
* Water level frequency
- Press and Hold
'Favorite'
&
'Option(Left)'
simultaneously.
Replace the
 
.
If FE is displayed again,
then replace the
  
.
If FE is displayed again,
then replace the
 
.
Check the
 
and the
(clogged).
The digits means water level frequency. (10
-1
kHz)
ex) 241 : Water level frequency = 241 x 10
-1
kHz
24.1 kHz
27
Is the air chamber and the tube clogged?
Replace the 
Main PCB
.
Is the 
Connector
connected correctly to
the 
Main PCB
and the 
Pressure Switch
?
Is the 
Harness
alright ?
Reconnect or repair the 
Connector
.
Or replace the 
Harness
.
Check air chamber and remove foreign material.
Replace the 
Pressure Switch
.
YES
YES
NO
Is the resistance of the 
Pressure Switch
out of range? 
[Pin1 ~ Pin3] 
21~23Ω)
NO
NO
YES
Pressure Sensor S/W Error (PE)
Page of 57
Display