49
VALVE     (STEAM) 
VALVE     (PRE-WASH)
VALVE     (NORMAL-WASH)
VALVE     (HOT)
1 Disconnect the wiring connector.
1
2
3
4
2 Remove the valve by two screws of the valve
holder.
• Rating : 220/240V 50/60Hz
• Resistant : 3.5~4.5kΩ
When reconnecting the connector
VALVE
(HOT) is option.
1 Open the door completely.
2 Remove the two screws from the hinge.
When removing the Door Assembly, it is
necessary to hold the Bracket that is inner of
the Cabinet Cover.
First, prepare a bucket to put in the remained
water.
Drain from hose.
VIOLET/BLACK-BLACK
WHITE/BLACK-BLACK
GRAY/BLACK
BLACK/WHITE
INLET VALVE
DOOR
Removing method of  remaining water
4
50
2 Push out PANEL ASSEMBLY, CONTROL after
Push the hook(     ,     ) below.
1 The plate assembly(Top) is disassembled.
2 Pull out the drawer and unscrew 2 screws.
1 Unscrew two screws.
3 Unscrew the screws from the lower cover.
2 The cabinet cover clamp is removed by
special jig for service and the gasket is
released.
3 Two screws are unscrewed.
4 Unscrew all the screws on the upper and
lower sides of the CABINET COVER.
1
2
3 Lift the side the Control Panel Assembly and
pull it out
CABINET COVER
51
1 Lift and separate the cabinet cover.
NOTE: When assembling the CABINET
COVER, connect the Door S/W connector.
• Just check cut-off.
• Check the operating time.
* Door Locking time : 
1~8
sec.
Check the time between from
input the power to parts
move up, then Door locked.
* Door Releasing time : 
25~100
sec.
Check the time between from off
the power to parts
move down, then Door released.
1
1
1
1 Unscrew two screws and cabinet cover
disassembled.
2 The Door Lock S/W is disconnected  from the
wiring connector and the strap.
SWITCH ASSY, DOOR LOCK
52
• V ~ U (8~11Ω)
• U ~ W (8~11Ω)
• W ~ V (8~11Ω)
Motor Stator
U V W
Hall Sensor
Ha
Hb
Common
• Common ~ Ha (5~15kΩ)
• Common ~ Hb (5~15kΩ)
1 Remove the housing coupled the TSG
(Connector, Hoses, Earth Screw)
[F1
❋03FDS]
2 Take out the screw of the TSG.
1 Remove the back cover.
2 After loosening the bolt, Rotor, pull out the
rotor.
1 Remove the 6  bolts from the stator.
2 Disconnect the 2 connectors.
1 Remove the hinges (Damper) at the Tub.
3 The hinge at the base is pulled off. 
(In directions  of the arrow)
2 The Hinge(Damper) at the base is  pulled off by
pressing on the snaps at the sharp end.
TSG (TURBO STEAM GENERATOR)
ROTOR ASSEMBLY, STATOR ASSEMBLY, FRICTION DAMPER
< Heater for STEAM>
• Rating : 230V 1000W
• Resistant : 42.5~49.5Ω