LG F1480FDS5 / F1480FDS6 Service Manual ▷ View online
49
VALVE (STEAM)
VALVE (PRE-WASH)
VALVE (NORMAL-WASH)
VALVE (HOT)
1 Disconnect the wiring connector.
1
2
3
4
2 Remove the valve by two screws of the valve
holder.
• Rating : 220/240V 50/60Hz
• Resistant : 3.5~4.5kΩ
• Resistant : 3.5~4.5kΩ
When reconnecting the connector
VALVE
(HOT) is option.
1 Open the door completely.
2 Remove the two screws from the hinge.
When removing the Door Assembly, it is
necessary to hold the Bracket that is inner of
the Cabinet Cover.
necessary to hold the Bracket that is inner of
the Cabinet Cover.
First, prepare a bucket to put in the remained
water.
water.
Drain from hose.
VIOLET/BLACK-BLACK
WHITE/BLACK-BLACK
GRAY/BLACK
BLACK/WHITE
INLET VALVE
DOOR
Removing method of remaining water
4
50
2 Push out PANEL ASSEMBLY, CONTROL after
Push the hook( , ) below.
1 The plate assembly(Top) is disassembled.
2 Pull out the drawer and unscrew 2 screws.
1 Unscrew two screws.
3 Unscrew the screws from the lower cover.
2 The cabinet cover clamp is removed by
special jig for service and the gasket is
released.
released.
3 Two screws are unscrewed.
4 Unscrew all the screws on the upper and
lower sides of the CABINET COVER.
1
2
3 Lift the side the Control Panel Assembly and
pull it out
CABINET COVER
51
1 Lift and separate the cabinet cover.
NOTE: When assembling the CABINET
COVER, connect the Door S/W connector.
COVER, connect the Door S/W connector.
• Just check cut-off.
• Check the operating time.
* Door Locking time :
1~8
sec.
Check the time between from
input the power to parts
move up, then Door locked.
input the power to parts
move up, then Door locked.
* Door Releasing time :
25~100
sec.
Check the time between from off
the power to parts
move down, then Door released.
the power to parts
move down, then Door released.
1
1
1
1 Unscrew two screws and cabinet cover
disassembled.
2 The Door Lock S/W is disconnected from the
wiring connector and the strap.
SWITCH ASSY, DOOR LOCK
52
• V ~ U (8~11Ω)
• U ~ W (8~11Ω)
• W ~ V (8~11Ω)
• U ~ W (8~11Ω)
• W ~ V (8~11Ω)
Motor Stator
U V W
Hall Sensor
Ha
Hb
Common
• Common ~ Ha (5~15kΩ)
• Common ~ Hb (5~15kΩ)
• Common ~ Hb (5~15kΩ)
1 Remove the housing coupled the TSG
(Connector, Hoses, Earth Screw)
[F1
❋03FDS]
2 Take out the screw of the TSG.
1 Remove the back cover.
2 After loosening the bolt, Rotor, pull out the
rotor.
1 Remove the 6 bolts from the stator.
2 Disconnect the 2 connectors.
2 Disconnect the 2 connectors.
1 Remove the hinges (Damper) at the Tub.
3 The hinge at the base is pulled off.
(In directions of the arrow)
2 The Hinge(Damper) at the base is pulled off by
pressing on the snaps at the sharp end.
TSG (TURBO STEAM GENERATOR)
ROTOR ASSEMBLY, STATOR ASSEMBLY, FRICTION DAMPER
< Heater for STEAM>
• Rating : 230V 1000W
• Resistant : 42.5~49.5Ω
• Rating : 230V 1000W
• Resistant : 42.5~49.5Ω
Click on the first or last page to see other F1480FDS5 / F1480FDS6 service manuals if exist.