Reference of checking the vibration
sensor error
sensor error
1. Range of vibraiton sensor data have to
change between 1900 and 2100 in
stopping the motor.
2. When the washer is spining, if the vibration
sensor data doesn’t change and keeps the
static value, we need to suspect
disconnection or noise effect.
3. In case of over-range, we also need to
check the status of vibration sensor.
1) Data View Type : Press and Hold Pre Wash and Temp key simultaneously, and then turn around the
knob until it display ‘043’.
2) Vibration Sensor Data = Vib_Sensor X-axis_01 x 100 + Vib_Sensor X-axis_02
3) Vibration Sensor status : If it display ‘000’, normal, ‘001’ incorrect initial position of vibration sensor or
offset error, 002 disconnection of vibration sensor.
Display Data View Mode
Y-axis_01
Y-axis_02
X-axis_01
X-axis_02
1)
043 Vib_Sensor XXX
XXX
Vib_Sensor
XXX
XXX XXX
XXX
XXX XXX
XXX
2)
Vib_Sensor XXX
3)
XXX
Vib_Sensor XXX
XXX
7-5 HOW TO CHECK THE VIBRATION SENSOR
22
If you press the Start/Pause button in error condition, any error except
will disappear and the
machine will change into the pause status.
In case of
In case of
,
, if the error is not resolved within 20 sec., and in case of other errors,
if the error is not resolved within 4 min., power will be turned off automatically and the error only will be
blinked. But in the case of
blinked. But in the case of
, power will not be turned off.
7-6. ERROR DISPLAY
ERROR
SYMPTOM
CAUSE
WATER
I
NLET
E
RROR
• Not reached to the water level(246) within 8 minutes
after water supplied or not reached to the preset
water level within 25 minutes.
Page 23
1
U
NBALANCE
E
RROR
• The appliance is tilted.
• Laundry is gatherd to one side.
Page 24
2
WATER
O
UTLET
E
RROR
• Not fully drained within 10 minutes.
Page 25
3
OVER
F
LOW
E
RROR
• Water is over flowing (over 8 level).
If " " is displayed, the drain pump operates
to drain the water automatically.
Page 27
4
P
RESSURE SENSOR
S/W
E
RROR
• The sensor pressure switch is out of order.
Page 28
5
D
OOR OPEN
E
RROR
• In case of operating the reservation function or the
other function with door opened. Close the door,
then the error display is resolved.
• The door switch is out of order.
Page 29
6
T
HERMISTOR(HEATING)
E
RROR
• The THERMISTOR is out of order.
Page 30
7
23
ERROR
SYMPTOM
CAUSE
MOTOR
L
OCKED
E
RROR
• The connector in the LEAD WIRE ASSEMBLY is
not connected to the connector of STATOR
ASSEMBLY.
Reconnect or repair the connector.
• The hall sensor is out of order/defective.
Replace the STATOR ASSEMBLY
Page 31
8
• Water leaks
Page 36
9
P
OWER
F
AILURE
W
A
TER
L
E
AKAGE
• The washer experienced a power failure
Press the start/pause button
10
24
7-7. TROUBLESHOOTING WITH ERROR
Water Inlet Error (IE)
Is the water tap closed?
[Note] Environmental safety check list
1. No water tap leakage & freeze.
2. No entanglement of water supply hose.
3. No water shortage.
4. No water supply hose leakage.
5. No the inlet filter clogged.
Check the
Water tap
and open it fully.
When there is water in the tub,
is the water level frequency
over 26.2KHz?
is the water level frequency
over 26.2KHz?
Are the inlet hose filters
clogged?
clogged?
Reconnect or repair the
Connector
.
Or replace the
Harness
.
Replace the
Inlet Valve
.
Is the
Connector
connected correctly to the
Main PCB
and the
Inlet Valve
? Or is the
Harness
alright ?
Check the
Air Chamber
and
the Tube
(clogged)
And When you check the water level frequency again,
if it is over 26.2KHz, you replace
if it is over 26.2KHz, you replace
the Pressure switch.
YES
YES
YES
NO
NO
Replace the
Main PCB
.
NO
YES
YES
NO
NO
NO
There are filters on the unit’s inlet valves to filter mineral
deposits or other debris from entering the unit.
If it clogged, water will not flow through these filters. Remove
hoses from unit, remove the filters and clean thoroughly.
deposits or other debris from entering the unit.
If it clogged, water will not flow through these filters. Remove
hoses from unit, remove the filters and clean thoroughly.
1
2
3
4
5
Is the each resistance of Inlet Valve within 3.5 ~4.5 kΩ ?
When the washing machine is started, is operated the
inlet valve?
inlet valve?
Pre. Valve
Main Valve
1
2
1
2