37
Pre Wash
(Powder)
Main Wash
(Powder)
Only
softener
Clean the drawer and dispenser.
Check point
YES
Water Leak
Is detergent & softener put in 
the correct compartment of the drawer? 
NO
Put it in the 
Correct Position
.
Replace the 
Dispenser Tray
.
Reference (Amount of Detergent & Softener)
Detergent
NO!!
OK!!
Is the 
Dispenser Tray
Damaged or warped?
1. Water Leak from Dispenser
Is the 
Detergent
caked or hardened?
Softener
YES
YES
NO
38
NO
2. Water Leak from Dispenser
Are the gasket (seal) 
and door cleaned regularly?
Is the door or gasket damaged?
Are the inlet hoses loose or cracked/split?
Replace the damaged parts.
Replace the 
Inlet Hoses
.
Clean the periphery of 
Gasket
and 
Door 
regularly.
3. Unknown – Water on Floor 
YES
Is the washer horizontal ?
Adjust the height of washing machine to be kept
horizontally. (Page 7)
NO
Are the drain filter and manual
drain hose open?
YES
NO
Check!!
Turn the filter cap clockwise to close.
YES
YES
NO
39
9. DISASSEMBLY INSTRUCTIONS
Disassemble and repair the parts after pulling out power cord from the outlet.
1 Unscrew the screws on the top plate.
3 The cover(Inner) is disassembled.
2 The plate assembly(Top) is pulled back and
then upward to arrow direction. 
1 Pull out the drawer and unscrew 2 screws.
2 Lift the side the Control Panel Assembly and
pull it out 
1 Two screws is unscrewed.
2 Push out PANEL ASSEMBLY, CONTROL after
Push the hook below.
1 The PWB assembly(Display) is disconnected.
2 When 7 screws are unscrewed on the PWB
insulator and the PWB assembly(Display) is
disassembled from the PWB insulator.
CONTROL PANEL
40
1 The back cover is removed.
2 One screw is unscrewed.
3 Pull the PWB assembly(Main) to arrow
direction
4 Two screws is unscrewed.
5 The cover of PWB assembly(Main) is
removed.
6 Disconnect connector from the wiring.
PWB ASSEMBLY(MAIN)
1 The plate assembly(Top) are disassembled.
3 Two screws are unscrewed.
2 Pull the drawer to arrow direction.
1 The hose clamps and the hose are
disassembled.
2 The ventilation bellows are disassembled on
the tub.
DISPENSER ASSEMBLY
Page of 51
Display

Click on the first or last page to see other F1403YD25 / F1403YD26 service manuals if exist.