LG F1403YD2 Service Manual ▷ View online
29
NO
Are the resistance of the
Hall Sensor
5~15kΩ?
Motor Locked Error (LE)
[Pre Check]
• Gentle wash cycles, such as Perm Press, Delicates, Hand Wash, and Wool/Silk should only be used for smaller loads.
• Gentle wash cycles, such as Perm Press, Delicates, Hand Wash, and Wool/Silk should only be used for smaller loads.
Because these cycles are more gentle in tumbling and spinning, putting too much in the drum can register an issue
with the motor. Remove items, reset unit and test with a Rinse/Spin cycle.
with the motor. Remove items, reset unit and test with a Rinse/Spin cycle.
• Don’t replace the PCB, when the hall sensor is replaced.
Replace the PCB, when the LE is displayed after replacing the hall sensor.
Is the
Connector
connected correctly to
the
Main PCB
and the
Motor
?
Or is the
Harness
alright ?
YES
NO
YES
YES
YES
YES
NO
Disassemble the
Rotor
.
Are the
Magnet
of rotor cracked or broken?
• Ha ~ Common
: 5 ~ 15 kΩ
• Hb ~ Common
: 5 ~ 15 kΩ
Replace the
Main PCB
.
Press the
Power
button &
Start / Pause
button.
Does the
Drum
stop when the start/pause button is pressed to start the cycle ?
Or Sometimes does the
Drum
rotate weakly (under 15rpm)?
Magnet
Ha
Hb
Common
Are the resistance same
between
between
Stator
points?
V~U / U~W / W~V : 8~11Ω
V U W
V U W
Reconnect or repair the
Connector
.
Or replace the
Harness
.
Replace the
Rotor
.
Replace the
Hall Sensor
.
Disassemble
hall sensor carefully.
(Next page)
NO
Replace the
Stator
.
30
Disassemble the Hall Sensor
1) Disassemble the hook of Hall Sensor by (-) driver.
2) Pull up Hall Sensor slowly as shown in picture.
1) Adjust the hole of Hall Sensor to
the hooks of stator as picture.(red circled)
2) Push down the Hall sensor,
and assemble to the hook for sure.
Caution
If you disassemble by force,not following the directions,
the hooks of stator(red circled) might broke up.
Hence need change of stator assembly.
the hooks of stator(red circled) might broke up.
Hence need change of stator assembly.
So disassemble cautiously.
1
Assemble the Hall Sensor
2
[Note]
Hall Sensor Part No.
• 24” / 25” : 6501KW2001A
• 24” / 25” : 6501KW2001A
• 27” : 6501KW2002A
31
Is the resistance of the
Thermistor
out of range
2.5~180K
Ω at 105~0°C?
Disassemble the
Cabinet cover
and
Condensing
Bellows
.
Is there any foreign object in
Condensing Bellows
?
Disassemble the
Dry Fan Assy
and
Dry Duct Upper
,
and clean foreign object in
Duct and Fan
.
Is the
Connector
connected correctly to
the
Main PCB
and the
Dry Heater
or
Fan Motor
?
Or is the
Harness
alright?
Reconnect or repair the
Connector
.
Or replace the
Harness
.
Replace the
Thermistor
.
Clean the
Bellows
.
YES
NO
Check for
Dry Heater
trouble.
Page 24
Check for
Dry Fan Motor
trouble.
Page 25
Dry Heater Error (dHE)
YES
YES
NO
NO
32
Is
Thermostat
closed ?
After power off, is the resistance of
Dry Heater
out of
range 33~37Ω?
Replace the
Dry Heater
.
Dry Heater Trouble
YES
YES
NO
Replace the
Thermostat
.
NO
Replace the
PWB assembly (main)
.
NO
When checking voltage between
connectors(1,2)
on drying, is the voltage AC 220-240V as the figure ?
1
2
Click on the first or last page to see other F1403YD2 service manuals if exist.