LG F1296TDT23 / F1296TDT24 / F1496TDT23 / F1496TDT24 Service Manual ▷ View online
36
1
Take apart the cabinet gasket clamp.
2
Unscrew 2 screws from the cabinet cover.
4
Take apart the lower cover.
3
Open the lower cover cap and unscrew 1
screw inside.
screw inside.
1
Disassemble the control panel. (page 24)
2
Unscrew all the screws on the upper and lower
sides of the cabinet cover.
sides of the cabinet cover.
1
Take apart the tub gasket clamp.
2
Make sure that the drain hole of the gasket is
put beneath when reassembling the gasket.
put beneath when reassembling the gasket.
efer to the arrow mark on the tub cover.
GASKET ASSEMBLY
37
1
Remove the BACK COVER.
2
Unscrew the bolt to pull out the ROTOR
assembly.
assembly.
1
Disconnect the wiring connector.
2
Unscrew 6 bolts from the STATOR.
3
Remove the STATOR.
1
Pull out the hinge, pressing its snap.
2
Do not use the pulled-out hinge again. It may
be taken off during operation.
be taken off during operation.
ROTOR ASSEMBLY, STATOR ASSEMBLY, FRICTION DAMPER ASSEMBLY
Rotor
Bolt
(1)
Hinge,
Damper
Damper
(ROTOR ASSEMBLY)
(STATOR ASSEMBLY)
(DAMPER)
• V ~ U (8~11Ω)
• U ~ W (8~11Ω)
• W ~ V (8~11Ω)
• U ~ W (8~11Ω)
• W ~ V (8~11Ω)
Note : Hook of connector (1) is on the backside
Motor Stator
U V W
• Common ~ Ha (5~15kΩ)
• Common ~ Hb (5~15kΩ)
• Common ~ Hb (5~15kΩ)
Hall Sensor
Ha
Hb
Common
38
PUMP
1
Remove pump outlet hose.
2
Remove tub pump bellows.
3
Remove cap (Remaining Hose.)
4
Disconnect the wiring.
5
Unscrew 2 screws.
6
Remove the pump.
HEATER
1
Loosen the M6 heater nut to pull out the
heater.
heater.
CAUTION
When mounting the heater, be sure to insert
the heater into the heater clip on the bottom
of the tub.
the heater into the heater clip on the bottom
of the tub.
Tub Pump
Bellows
Bellows
Pump Outlet Hose
• Rating : 220~240V 2000W
• Resistant : 24.7~28.0Ω
• Resistant : 24.7~28.0Ω
• Rating : 220~240V 50HZ 30W
• Resistant : 160~177Ω
• Resistant : 160~177Ω
M6 heater nut
39
SWITCH ASSEMBLY, DOOR LOCK
1
Take apart the cabinet cover clamp and
release the gasket.
release the gasket.
2
Unscrew 2 screws holding the door lock.
3
Disconnect the door lock from the wiring
connector.
connector.
WHEN FOREIGN MATERIAL IS STUCK BETWEEN DRUM AND TUB
1
Remove the heater.
2
Remove the foreign material (wire, coin and
others) by inserting a long bar through the
hole.
others) by inserting a long bar through the
hole.
• Just check cut-off.
• Check the operating time.
• Check the operating time.
* Door Locking time :
1~8
sec.
Check the time between from
input the power to parts
move up, then Door locked.
* Door Releasing time :
25~100
sec.
Check the time between from off
the power to parts
move down, then Door released.
1
1
1
Click on the first or last page to see other F1296TDT23 / F1296TDT24 / F1496TDT23 / F1496TDT24 service manuals if exist.