LG F1280TD6 Service Manual ▷ View online

28
1
NO
Is the door closed?
Is the Door assembly in line with door
switch ? 
Lift up & Close the door. 
If the dE is displayed, Replace the 
Door Bracket
.
Close the door totally.
YES
Reconnect or repair the 
Connector
.
Or replace the 
Harness
.
NO
Replace the 
MAIN PWB
ASSEMBLY.
NO
Replace the 
Latch Hook
.
NO
Replace the 
Door switch
.
NO
Does the 
Spring
of 
Latch Hook
actuate? 
Door Open Error (dE)
YES
YES
YES
NO
Touching
or
Is the 
Connector
connected correctly to
the 
Main PCB
and the 
Door Switch
?
Or is the 
Harness 
alright ?
YES
Is there clicking sound once or twice when the
START/PAUSE button is pressed to start the
cycle? No    Replace the  MAIN PWB ASSEMBLY.
Scratch by Latch Hook
Does the 
Door Switch
operate as follows?
* Door Locking time : 
1~8
sec.
Check the time between from
input the power to parts
move up, then Door locked.
* Door Releasing time : 
25~100
sec.
Check the time between from
off the power to parts
move down, then Door released.
1
1
29
YES
Is the resistance of the 
Thermistor
out of range 44 ~
53 KΩ at 25°C? (Page 17) 
Replace the 
Main PCB
.
Is the 
Connector
connected correctly to 
the 
Main PCB
and the 
Thermistor
and the 
Heater
?
Or is the 
Harness
alright ?
Reconnect or repair the 
Connector
.
Or replace the 
Harness
.
Replace the 
Thermistor
.
YES
Replace the 
Heater
.
YES
NO
Is the resistance of the 
Heater
out of range 24.5 ~
28.5Ω (for Washing) or 42.5 ~ 49.5Ω (for Steam) ?
(Page 19) 
[Note] Thermistor Spec
NO
NO
Thermistor (Heating) Error (tE)
S
P
E
C
Temp
30 °C
40 °C
60 °C
70 °C
95 °C
105 °C
Resistance (kΩ)
MIN
36.35
39.45
42.72
24.20
26.05
27.97
11.43
12.12
12.82
8.088
8.514
8.940
3.544
3.791
4.045
2.617
2.816
3.023
STD
MAX
Heater for Washing
Heater for Steam
30
NO
Are the resistance of the 
Hall Sensor
5~15kΩ?
Motor Locked Error (LE)
[Pre Check]
• Gentle wash cycles, such as Perm Press, Delicates, Hand Wash, and Wool/Silk should only be used for smaller loads.
Because these cycles are more gentle in tumbling and spinning, putting too much in the drum can register an issue
with the motor. Remove items, reset unit and test with a Rinse/Spin cycle.
• Don’t replace the PCB, when the hall sensor is replaced.
Replace the PCB, when the LE is displayed after replacing the hall sensor.
Is the 
Connector
connected correctly to 
the 
Main PCB
and the 
Motor
?
Or is the 
Harness
alright ?
YES
NO
YES
YES
YES
YES
NO
Disassemble the 
Rotor
.
Are the 
Magnet
of rotor cracked or broken?
• Ha ~ Common 
: 5 ~ 15 k
• Hb ~ Common 
: 5 ~ 15 k
Replace the 
Main PCB
.
Press the 
Power
button & 
Start / Pause
button.
Does the
Drum 
stop when the start/pause button is pressed to start the cycle ?
Or Sometimes does the 
Drum
rotate weakly (under 15rpm)?
Magnet
Ha
Hb
Common
Are the resistance same
between 
Stator
points?
V~U / U~W / W~V : 8~11Ω
V  U  W
V   U   W
Reconnect or repair the 
Connector
.
Or replace the 
Harness
.
Replace the 
Rotor
.
Replace the 
Hall Sensor
.
Disassemble 
hall sensor carefully. 
(Next page)
NO
Replace the 
Stator
.
31
Disassemble the Hall Sensor
1) Disassemble the hook of Hall Sensor by (-) driver.
2) Pull up  Hall Sensor slowly as shown in picture. 
1) Adjust the hole of Hall Sensor to 
the hooks of stator as picture.(red circled)
2) Push down the Hall sensor, 
and assemble to the hook for sure.
Caution
If you disassemble by force,not following the directions, 
the hooks of stator(red circled) might broke up.
Hence need change of stator assembly. 
So disassemble cautiously.
1
Assemble the Hall Sensor
2
[Note]
Hall Sensor Part No.
• 24” / 25” : 6501KW2001A
• 27” : 6501KW2002A 
Page of 56