20
8-2. FAULT DIAGNOSIS AND TROUBLESHOOTING
1. Be careful of electric shock or disconnecting the parts while troubleshooting.
2. First of all, check the connection of each part terminal with wiring diagram.
3. If you replace the PWB assembly (Main), put in the connectors correctly.
CAUTION
NO POWER
ALL BUTTONS ARE INOPERABLE
When measuring the voltage of the
outlet, is the voltage AC 220-240V?
Check the fuse
YES
NO
When measuring the voltage of
Yellow(BN), Black(BL) connector of the
PWB assy, is the voltage AC 220-240V?
Check the harness
Assembly.
YES
NO
Replace PWB assembly.
Cancle the
Child-Lock
NO
YES
First, unplug the power cord and plug
again.
Check the buttons are working.
Is Child Lock set?
Visit to check
Normal
NO
YES
<PWB ASSEMBLY (MAIN)>
21
NO WATER SUPPLY
Is the water supply shut-off?
Is the tap opened?
Open the tap.
NO
YES
NO
Water level frequency below 240?
Check the chamber (Air)
and the tube clogged
with impurity.
NO
YES
Is the inlet valve filter clogged with
impurity?
Is resistance of the inlet valve connector
between the 2 to 8 kΩ?
Clean the filter.
NO
YES
Check the voltage between each
terminals of inlet Valve is 220 - 240V~.
(Refer to 7-2 TEST MODE)
Replace the inlet valve.
Replace PWB assembly
YES
NO
NO
DETERGENT DOES NOT FLOW IN
Is water supplied?
Refer to solution
NO INLET
YES
NO
Are receptacles correctly connected to
the terminals of inlet valve?
Check the wiring on the
dispenser.
YES
NO
Is detergent put in the correct
compartment of the drawer?
Is the detergent caked or hardened?
Clean the drawer.
Put the detergent in the
correct position
PRE+MAIN
MAIN WASH
: Detergent
YES
YES
NO
max
SOFTENER
MAIN
WASH
PRE-
WASH
option (HOT)
option (HOT)
22
SOFTENER DOES NOT FLOW IN
ABNORMAL SOUND
Is water supplied?
Are receptacles correctly connected to
the terminals of inlet valve?
Refer to
NO WATER SUPPLY
Check the wiring on the
dispenser.
YES
YES
NO
Is softener put in the correct
compartment of drawer?
Put it in the correct
compartment.
NO
Is the softner cap clogged?
NO
Clean the cap and
drawer.
YES
YES
Is the motor bolt loosened?
Is there friction noise from the motor?
Fix the bolt tightly.
Replace the STATOR
assembly or ROTOR
assembly.
NO
YES
YES
option (HOT)
23
HEATING WITHOUT WATER
Water level frequency 252 or more?
Water level frequency between
230~245~?
Replace the sensor
(pressure)
YES
NO
Checking voltage between two
[Yellow(RD), Black(YL)]pins as press
the power button is the voltage 
220 - 240V~ in without water condition
Replace the PWB
assembly
YES
DRAIN MALFUNCTIONING
Is the drain hose twisted or frozen?
Repair drain hose
NO
YES
Is the impeller of the drain pump clogged?
Remove foreign
material.
NO
YES
Is the connector disconnected,
disassembled?
Is the coil of drain pump cut-off?
(resistance of coil is 90~160Ω )
When checking voltage between
connectors (     ,     ) on spinning, is the
voltage 220 - 240V~ as the figure?
Replace the pump
assembly
Replace the PWB
assembly (Main)
Reconnect or repair the
connector
NO
NO
YES
NO
YES
1
2
AC 220~240V
PWB ASSEMBLY (MAIN)
PWB ASSEMBLY (MAIN)
Page of 36