20
NO
NO
NO
YES
YES
YES
YES
option (HOT)
MAX
max
YES
YES
NO
Fix the bolt tightly.
Replace the STATOR
assembly
assembly.
or ROTOR
Is the motor bolt loosened?
Is there friction noise from the motor?
ABNORMAL SOUND
SOFTENER DOES NOT FLOW IN
Refer to
^NO WATER SUPPLY_
Check the wiring on the 
dispenser.
Put it in the correct
compartment.
Clean the cap and
drawer.
Is water supplied?
Are receptacles correctly connected to the
terminals of inlet valve?
Is softener put in the correct compartment of
drawer?
Is the softner cap clogged?
21
AC 220-240V
NO
YES
YES
YES
YES
NO
NO
NO
NO
YES
YES
NO
PWB ASSEMBLY (MAIN)
PWB ASSEMBLY (MAIN)
Replace the sensor 
(pressure)
Replace the PWB
assembly  
Repair drain hose
Remove foreign
material.
Reconnect or repair the
connector
Replace the pump
assembly
Replace the PWB
assembly (Main) 
When pressing [Intensive] button and 
[Crease Care] button at the same time after draining, 
is  the water level frequency 252 or more?  
When pressing [Intensive] button and 
[Crease Care] button at the same time while wash,
is the water level frequency between 230~245~?
Checking voltage between two [Yellow(RD), 
Black(YL)]pins as press the power button is  
the voltage 220 - 240V~ in without water 
condition
Is the drain hose twisted or frozen?
Is the impeller of the drain pump clogged?
Is the connector disconnected,
disassembled?
Is the coil of drain pump cut-off?
(resistance of coil is 90~160
)
When checking voltage between connectors
(
,  ) on spinning, is the voltage 
220 - 240V~  as the figure?
HEATING WITHOUT WATER
DRAIN MALFUNCTIONING
22
NO
YES
YES
WASH HEATER TROUBLE
When checking the voltage between 
connector             the PWB assembly (Main)
during cotton 95°C washing ,Is the voltage 
220 - 240V    ?
Replace the PWB 
assembly (Main)
YES
NO
After power off and the heater terminal is
disconnected, is the resistance 10 to 30   ?
(1)
(1)
4
Replace the heater 
assembly
NO
After power off,is the resistance of wire
(RED-YELLOW) connectors between
10    to 30   ?
Normal
NO
YES
RED
YELLOW
1
2
3
  ~    
220 - 240V~
PWB ASSEMBLY (MAIN)
Replace the thermistor
(6322FR2046C)
Push the thermistor
tightly to the rubber.
When checking thermistor on the tub, 
Red
is the thermistor loosened above 2mm from 
the rubber?
HEATING CONTINUOUSLY ABOVE 
THE SETTING WATER TEMPERATURE
3
23
NO
YES
YES
YES
NO
NO
YES
NO
NO
YES
SPIN TROUBLE
Check the sensor
(Pressure) or hose 
(Sensor). 
If the problem is on the
sensor or the hose, replace
the sensor or the hose.
Normal
Correct the connector.
Correct the connector.
Replace the STATOR
assembly.
(4417EA1002D)
While spinning, is the frequency of the
water level 248 or more? The frequency can be 
checked by pressing the Intensive button
and Crease Care button at the same time 
 on the program.
When pressing Spin button and Temp. button and 
POWER button at the same time after power off,
 press the START/PAUSE button 2 times,
is the drum low speed spin?
Is it disconnected, or disassembled?
[White : 3pin ( ), Red:3pin ( ), 
Red:3pin ( ), National:4pin ( )]
Is it disconnected, or disassembled?
White : 3pin( ), White:4pin( )]
Check the motor connector, Is the resistance of
the terminal same as the figure?
MOTOR TERMINAL (1)
Resistance of terminal: 
Replace the PWB assembly.
(2)
(1)
~
~
~
/
/
Page of 34